• When a disk fails, the virtual disk still works, but it is operating in a<br />

degraded state. The data is reconstructed from the surviving disks.<br />

• Better read performance, but slower write performance.<br />

• Redundancy for protection of data.<br />

Related Information:<br />

• Organizing Data <strong>Storage</strong> for Availability and Performance<br />

• Comparing RAID Level and Concatenation Performance<br />

• Controller-supported RAID Levels<br />

• Number of Physical Disks per Virtual Disk<br />

• Maximum Number of Virtual Disks per Controller<br />

RAID Level 6 (Striping with additional distributed parity)<br />

RAID 6 provides data redundancy by using data striping in combination with<br />

parity information. Similar to RAID 5, the parity is distributed within each<br />

stripe. RAID 6, however, uses an additional physical disk to maintain parity,<br />

such that each stripe in the disk group maintains two disk blocks with parity<br />

information. The additional parity provides data protection in the event of<br />

two disk failures. In Figure 3-5, the two sets of parity information are<br />

identified as P and Q.<br />