Table 7. Instrument summary<br />
Instrument Parameter Range Comments<br />
Inertial mobility instuments (cascade impactors)<br />
Micro-orifice Aerodynamic 0.056 - 10 um * Not real-time, gravimetric and chemical<br />
uniform deposit diameter analysis performed after collection.<br />
impactor (MOUDI)<br />
Nano- MOUDI Aerodynamic 0.010 - 18 um * Same as MOUDI<br />
diameter evaporate.<br />
01/14/99 Page 28<br />
* Low pressure may cause volatile particles<br />
Electrical low Aerodynamic 0.030 - 10 um * Near realtime with time resolution from 2 - 15 s.<br />
pressure impactor diameter * Can measure ambient concentrations, but low<br />
(ELPI) pressure may cause volatile particles to evaporate.<br />
Electrical mobility instruments<br />
Electrical aerosol Electrical Mobility 0.003 - 1 um * Time resolution between 2-3 min, 11 size intervals.<br />
analyzer Equivalent * Strongly distorted results if concentration and size<br />
Diameter change during scan.<br />
* More sensitive to these changes than SMPS.<br />
* Requires high dilution (> 200:1) to prevent<br />
electrometer saturation.<br />
* Results for diameters < 10 nm are questionable<br />
unless number concentrations are high, due to<br />
diffusional losses.<br />
* Pre-classification stage must be used to remove<br />
particles larger than 1.0 um for <strong>diesel</strong> aerosol<br />
measurements<br />
Differential mobility Electrical Mobility 0.01 - 0.5 um * Discrete changes in electric field <strong>of</strong> DMPS makes<br />
particle sizer Equivalent <strong>sampling</strong> for entire range slower than for SMPS.<br />
(DMPS) Diameter * Biased results if concentration and size change<br />
during scan.<br />
* Pre-classification stage must be used to remove<br />
particles larger than 1.0 um for <strong>diesel</strong> aerosol<br />
measurements<br />
Scanning mobility Electrical Mobility 0.010 - 0.7 um * 2 - 4 min scan time for 100 size intervals - can ramp<br />
particle sizer Equivalent DMA electric field to reduce scan time.<br />
(SMPS) Diameter * Time resolution <strong>of</strong> a few seconds for a single<br />
channel.<br />
* Scan times as short as 30 s may be used with lost<br />
resolution<br />
* Biased results if concentration and size change<br />
during scan.<br />
* Pre-classification stage must be used to remove<br />
particles larger than 1.0 um for <strong>diesel</strong> aerosol<br />
measurements<br />
nano-Differential Electrical Mobility 3 - 50 nm * Time resolution <strong>of</strong> about 10 s required to scan<br />
mobility analyzer Equivalent all intervals.<br />
(nano-DMA) Diameter * Not fully characterized and developed