Table 7. Instrument summary<br />

Instrument Parameter Range Comments<br />

Inertial mobility instuments (cascade impactors)<br />

Micro-orifice Aerodynamic 0.056 - 10 um * Not real-time, gravimetric and chemical<br />

uniform deposit diameter analysis performed after collection.<br />

impactor (MOUDI)<br />

Nano- MOUDI Aerodynamic 0.010 - 18 um * Same as MOUDI<br />

diameter evaporate.<br />

01/14/99 Page 28<br />

* Low pressure may cause volatile particles<br />

Electrical low Aerodynamic 0.030 - 10 um * Near realtime with time resolution from 2 - 15 s.<br />

pressure impactor diameter * Can measure ambient concentrations, but low<br />

(ELPI) pressure may cause volatile particles to evaporate.<br />

Electrical mobility instruments<br />

Electrical aerosol Electrical Mobility 0.003 - 1 um * Time resolution between 2-3 min, 11 size intervals.<br />

analyzer Equivalent * Strongly distorted results if concentration and size<br />

Diameter change during scan.<br />

* More sensitive to these changes than SMPS.<br />

* Requires high dilution (> 200:1) to prevent<br />

electrometer saturation.<br />

* Results for diameters < 10 nm are questionable<br />

unless number concentrations are high, due to<br />

diffusional losses.<br />

* Pre-classification stage must be used to remove<br />

particles larger than 1.0 um for <strong>diesel</strong> aerosol<br />

measurements<br />

Differential mobility Electrical Mobility 0.01 - 0.5 um * Discrete changes in electric field <strong>of</strong> DMPS makes<br />

particle sizer Equivalent <strong>sampling</strong> for entire range slower than for SMPS.<br />

(DMPS) Diameter * Biased results if concentration and size change<br />

during scan.<br />

* Pre-classification stage must be used to remove<br />

particles larger than 1.0 um for <strong>diesel</strong> aerosol<br />

measurements<br />

Scanning mobility Electrical Mobility 0.010 - 0.7 um * 2 - 4 min scan time for 100 size intervals - can ramp<br />

particle sizer Equivalent DMA electric field to reduce scan time.<br />

(SMPS) Diameter * Time resolution <strong>of</strong> a few seconds for a single<br />

channel.<br />

* Scan times as short as 30 s may be used with lost<br />

resolution<br />

* Biased results if concentration and size change<br />

during scan.<br />

* Pre-classification stage must be used to remove<br />

particles larger than 1.0 um for <strong>diesel</strong> aerosol<br />

measurements<br />

nano-Differential Electrical Mobility 3 - 50 nm * Time resolution <strong>of</strong> about 10 s required to scan<br />

mobility analyzer Equivalent all intervals.<br />

(nano-DMA) Diameter * Not fully characterized and developed