3.2. Layout<br />

<strong>HR</strong> MODEL<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

pic. 5<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

20<br />

21<br />

22<br />

23<br />

24<br />

25<br />

1. Condensate drain<br />

2. Modulating gas valve<br />

3. CH temperatura probe<br />

4. Burner nozzles<br />

5. Flame detection electrode<br />

6. Safety thermostat<br />

7. Heat exchanger<br />

8. Sealed combustion chamber<br />

9. Flue gas extraction fan<br />

10. Flue gas pressure test point<br />

11. Flue gas pressure safety switch<br />

12. Flue gas pressure micro switch<br />

13. Condensate detection probe<br />

14. Safety thermostat<br />

15. Air intake/flue gas pipe<br />

16. Flue gas recoverer<br />

17. Flue gas pressure test point<br />

18. Expansion vessel filling tap<br />

19. Expansion vessel<br />

20. Ignition electrode<br />

21. Air purging device<br />

22. Pump<br />

23. Water pressure switch<br />

24. 3-bar safety valve<br />

25. Unloading tap<br />

<strong>HC</strong> MODEL<br />

17<br />

16<br />

15<br />

14<br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

31<br />

2<br />

1<br />

30<br />

pic. 6<br />

G<br />

S<br />

18<br />

19<br />

20<br />

21<br />

22<br />

22<br />

23<br />

24<br />

25<br />

32<br />

26<br />

27<br />

28<br />

29<br />

1. Condensate drain<br />

2. DHW temperature probe<br />

3. Modulating gas valve<br />

4. CH temperature probe<br />

5. Burner nozzles<br />

6. Burner<br />

7. Flame detection electrode<br />

8. Safety thermostat<br />

9. Heat exchanger<br />

10. Sealed combustion chamber<br />

11. Flue gas extraction fan<br />

12. Flue gas pressure test point<br />

13. Flue gas pressure safety switch<br />

14. Flue gas pressure micro switch<br />

15. Condensate detection probe<br />

16. Flue gas recoverer<br />

17. Safety thermostat<br />

18. Air intake/flue gas intake<br />

19. Flue gas pressure test point<br />

20. Expansion vessel filling tap<br />

21. Expansion vessel<br />

22. Ignition electrode<br />

23. Air purging device<br />

24. Pump<br />

25. Water pressure switch<br />

26. Safety valve<br />

27. DHW flow limiting device (max 10 litre/minute)<br />

28. Flow switch<br />

29. Mains water inlet filter<br />

30. Adjustable by-pass<br />

31. Three way valve<br />

32. Secondary plate heat exchanger<br />