BOILER STATUS MALFUNCTION PROBABLE CAUSE SOLUTION<br />
CH probe is disconnected<br />
Reconnect it.<br />
The boiler has shut down, red light 2<br />
and yellow light 8 are flashing.<br />
Boiler will automatically resume<br />
operation when the problem has<br />
been solved.<br />
CH probe is not operational.<br />
CH probe is faulty.<br />
Replace it.<br />
DHW probe disconnected.<br />
Reconnect it.<br />
The boiler has shut down and red<br />
light 2 is flashing.<br />
Boiler will automatically resume<br />
operation when the problem has<br />
been solved.<br />
DHW probe is not operational.<br />
Model <strong>HC</strong>.<br />
DHW probe faulty.<br />
Replace it.<br />
Boiler is not providing DHW<br />
DHW flow meter is not operational.<br />
Model <strong>HC</strong><br />
Insufficient system pressure or<br />
capacity<br />
Flow meter sensors is disconnected<br />
or faulty.<br />
Check DHW system.<br />
Check DHW flow meter filter.<br />
Replace or reconnect it.<br />
Flow meter is stuck.<br />
Replace it.<br />
45