02.01.2015 Views

Alkon Catalog

Alkon Catalog

Alkon Catalog

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDY TECHNICAL INFORMATION<br />

INDY AU SERIES OPERATING SPECIFICATIONS<br />

• Media: Air and inert gasses<br />

• Filtration: 40 microns<br />

• Pressure Range:<br />

Pilot Air - Maximum 30 psig to 150 psig and not less<br />

than main air supply. Vacuum to 30 psig available.<br />

Main Supply - 30 to 150 psig (standard)<br />

• Temperature: 0 o to 180 o F<br />

• Flow Capacity: 1.4 to 12.5 Cv<br />

• Lubrication: All valves are prelubricated and will<br />

operate with dry air (no additional lubrication required)<br />

However, a lubricated system will greatly extend the<br />

service life of any valve<br />

ELECTRICAL:<br />

AU-1 & AU-2 Electrical Characteristics<br />

Standard Voltage Inrush Current Holding Current Power<br />

120 VAC 50/60 Hz 60mA 50mA 6 watts<br />

24 VDC 60mA 60mA 1.44 watts<br />

AU-1 & AU-2 Multiple Voltage Electrical Characteristics<br />

Standard Voltage Inrush Current Holding Current Power<br />

24 - 120 VDC 55mA + 10% 50mA + 10% Actual Voltage x .055<br />

48 - 120 VAC 50/60 Hz 125mA + 25% 50mA + 10% Actual Voltage x .055<br />

AU-5 Electrical Characteristics<br />

Standard Voltage Inrush Current Holding Current Power<br />

110 VAC 50/60 Hz 130mA 80mA 8.8 watts<br />

120 VAC 50/60 Hz 110mA 70mA 8.4 watts<br />

240 VAC 50/60 Hz 60mA 30mA 7.2 watts<br />

24 VDC 290mA 290mA 6.9 watts<br />

120/60 Hz can be connected to 110/50 Hz.<br />

Encapsulated coils are standard.<br />

All solenoids are designed to meet or exceed<br />

UL and CSA standards.<br />

Coils are rated for continuous duty.<br />

75<br />

Cv Conversion to S.C.F.M.<br />

Cv P.S.I.G. S.C.F.M.<br />

1 40 27<br />

1 50 32<br />

1 60 37<br />

1 70 42<br />

1 80 47<br />

1 90 52<br />

1 100 57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!