INDY TECHNICAL INFORMATION<br />
INDY AU SERIES OPERATING SPECIFICATIONS<br />
• Media: Air and inert gasses<br />
• Filtration: 40 microns<br />
• Pressure Range:<br />
Pilot Air - Maximum 30 psig to 150 psig and not less<br />
than main air supply. Vacuum to 30 psig available.<br />
Main Supply - 30 to 150 psig (standard)<br />
• Temperature: 0 o to 180 o F<br />
• Flow Capacity: 1.4 to 12.5 Cv<br />
• Lubrication: All valves are prelubricated and will<br />
operate with dry air (no additional lubrication required)<br />
However, a lubricated system will greatly extend the<br />
service life of any valve<br />
ELECTRICAL:<br />
AU-1 & AU-2 Electrical Characteristics<br />
Standard Voltage Inrush Current Holding Current Power<br />
120 VAC 50/60 Hz 60mA 50mA 6 watts<br />
24 VDC 60mA 60mA 1.44 watts<br />
AU-1 & AU-2 Multiple Voltage Electrical Characteristics<br />
Standard Voltage Inrush Current Holding Current Power<br />
24 - 120 VDC 55mA + 10% 50mA + 10% Actual Voltage x .055<br />
48 - 120 VAC 50/60 Hz 125mA + 25% 50mA + 10% Actual Voltage x .055<br />
AU-5 Electrical Characteristics<br />
Standard Voltage Inrush Current Holding Current Power<br />
110 VAC 50/60 Hz 130mA 80mA 8.8 watts<br />
120 VAC 50/60 Hz 110mA 70mA 8.4 watts<br />
240 VAC 50/60 Hz 60mA 30mA 7.2 watts<br />
24 VDC 290mA 290mA 6.9 watts<br />
120/60 Hz can be connected to 110/50 Hz.<br />
Encapsulated coils are standard.<br />
All solenoids are designed to meet or exceed<br />
UL and CSA standards.<br />
Coils are rated for continuous duty.<br />
75<br />
Cv Conversion to S.C.F.M.<br />
Cv P.S.I.G. S.C.F.M.<br />
1 40 27<br />
1 50 32<br />
1 60 37<br />
1 70 42<br />
1 80 47<br />
1 90 52<br />
1 100 57