DETROIT LINE<br />

Air Pilot Operated Valves<br />

Air Pilot operated valves are recommended where it is desirable to<br />

substitute pilot air circuitry to replace solenoid operated valves.<br />

Typical applications would be where electrically operated valving<br />

would present a fire or explosion hazard. With controlled pilot signals<br />

air pilot systems have comparable response to electrically operated<br />

valves and in many cases system response is enhanced by their use.<br />

Specifications:<br />

Operating Pressure: (Main Valve) vacuum - 150 psig<br />

Pilot Pressure Required: 30 psig<br />

• For Normally Open 3-Way, Supply Port 3<br />

“VP” Series Solenoid Pilot Operated<br />

Features:<br />

• Meets All J.I.C. & Industrial Standards<br />

• Molded Coils are Standard<br />

• Fast Response and Low Inrush Current<br />

• Rugged Cast Aluminum Design<br />

• High Air Flow Capability<br />

• Delivers Millions of Trouble Free Cycles<br />

Available In:<br />

• 2, 3 or 4-Way Models<br />

• Single or Double Solenoid<br />

• Standard Voltages:<br />

120/60Hz. 240/60Hz. 24/60Hz.<br />

12VDC, 24VDC, 120VDC<br />

• Also Available with 3-Prong MS Electrical Connector (Consult Factory)<br />

• External Pilot Provision is field convertible - consult factory<br />

83<br />

Direct Solenoid Operated<br />

<strong>Alkon</strong> direct operated solenoid valves are excellent for vacuum or low<br />

pressure service or where application demands extremely fast response<br />

independent of operating pressure. Complete piping versatility for 3-Way<br />

models is also featured.<br />

Available With:<br />

• Single or Double Solenoid<br />

• DC Solenoids (Consult Factory)<br />

• Base Mounting Models on 4-Ways<br />

• Manual Override is Standard on all Models<br />

• Explosion Proof Models - (AC Only) Add Suffix “X” to end of<br />

model number<br />

Features:<br />

• Fast Response...Minimum Breakdown Friction<br />

• Minimum Moving Parts<br />

• Valves May Be Mounted in Any Position<br />

• Inlet and Outlet Ports May Be Restricted, Plugged or Used for<br />

Alternative Pressure Arrangements Without Affecting Operation of Valve<br />

• All Models Conform to J.I.C. and Industrial Standards<br />

• Standard Voltage 115/60Hz<br />

• For Normally Open 3-Way, Supply Port 3