Prescor safety valves:<br />

a complete range for the safety of your system<br />

If you are looking for reliable safety valves, you need<br />

look no further than <strong>Flamco</strong>'s Prescor range. The<br />

best protection for all sealed heating and chilled<br />

systems from overpressure. The Prescor valves are<br />

suitable for systems with a capacity of no higher than<br />

580 kW at 3.0 bar. Systems with greater capacity will<br />

need the heavy-duty Prescor S.<br />

The benefits of Prescor<br />

• High-quality materials and construction guarantee<br />

reliable function when you need it most.<br />

• If there is a rapid build-up of pressure, the valve will<br />

'pop' open. The pressure can then be discharged<br />

quickly.<br />

• CE conformity mark.<br />

• The opening pressure of all valves is individually<br />

tested 100%.<br />

Cap of high-impact<br />

plastic.<br />

Anti-ageing spring steel prevents the<br />

set pressure from drifting.<br />

Robust brass housing.<br />

The diaphragm prevents moisture and dirt<br />

from getting into the moving parts of the<br />

safety valve during blowing off.<br />

Valve seal of high-quality rubber, heat-resistant<br />

to 140 ºC. The hardness of the rubber is<br />

adapted to the set pressure of the valve. These<br />

properties mean that the valve will not stick to<br />

the valve seat.<br />

PRESCOR<br />

All Prescor safety valves are set to the specified<br />

opening pressure during manufacture. This setting<br />

cannot be adjusted. It is important to check the<br />

requirements for the Prescor valve in advance.<br />

When choosing a Prescor safety valve, the capacity<br />

shown on the safety valve must exceed the nominal<br />

boiler capacity.<br />

The set pressure and maximum output for which the<br />

valve is suitable are indicated on the valve.<br />

Mount on the boiler, or as close as possible to it, in the supply<br />

line. Never fit a stopcock between the boiler and the valve.<br />