Chemical joint<br />
Description<br />
The CHEMICAL JOINT is a material with pasty<br />
consistency, which is cured at ambient temperature,<br />
forming a resistant joint.<br />
The joints used by MERITOR are:<br />
174 and 574 (LOCTITE) and NEUTRAL SI-LI-<br />
CONE (DOW CORNING 780, LOCTITE 5699,<br />
TREE BOND 1216, RHODIA 567 or 666).<br />
Cleaning<br />
CAUTIONly clean both the junction surfaces,<br />
eliminating the residue of the previous joint,<br />
dirt, oil, grease or humidity. This residue should<br />
be removed using a spatula or sandpaper,<br />
followed by cleaning with a solvent free of oil as<br />
xylol, or toluene or methylethylketone.<br />
Avoid causing grooves in these surfaces, as<br />
they can lead to later leakage.<br />
Procedure For Application<br />
A - Apply a continuous fillet of approximately 3<br />
mm in diameter when the joint is NEUTRAL<br />
SILICONE or apply with a brush when it is<br />
FAG-3 , all over one of the coupling surfaces<br />
and all the fastening holes, to en-sure a<br />
total Seal which avoids leakage;<br />
FILLET APPROX.<br />
3 mm IN DIAMETER<br />
Drying<br />
Before application, ensure that the junction surfaces<br />
are perfectly dry.<br />
Figure 42<br />
CAUTION:<br />
Excessive application causes the<br />
joint mass to migrate inside the<br />
unit, and also leads to difficulties<br />
in future disassembly. Failures in<br />
applying the joint Cord may cause<br />
future leakage.<br />
B - After the application, join the two surfaces<br />
immediately, so that the joint cord spreads<br />
in a uniform manner;<br />
C - Then, tighten the fastening components<br />
with the values specified in the TIGHTE-<br />
NING TORQUES section.<br />
20 <strong>MAINTENANCE</strong> <strong>MANUAL</strong>