PRIMERGY SX30 Configurator
PRIMERGY SX30 Configurator
PRIMERGY SX30 Configurator
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>PRIMERGY</strong> <strong>SX30</strong><br />
System configurator and order-information guide<br />
May 2008<br />
Contents<br />
Part 1:<br />
Part 2:<br />
Part 3.1:<br />
Part 3.2:<br />
Part 3.3:<br />
Part 4:<br />
Part 5:<br />
Part 6:<br />
Part 7:<br />
General notes<br />
<strong>SX30</strong> Structure<br />
<strong>SX30</strong> <strong>Configurator</strong><br />
<strong>SX30</strong> Single Channel <strong>Configurator</strong><br />
<strong>SX30</strong> Cluster U320 <strong>Configurator</strong><br />
Upgrading<br />
<strong>SX30</strong> Lines<br />
<strong>SX30</strong> Cabling<br />
Change Report<br />
<strong>PRIMERGY</strong> Server
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> <strong>Configurator</strong><br />
Part 1: General notes<br />
To make the configurator easier to follow, the <strong>PRIMERGY</strong> <strong>SX30</strong> configurator has been divided into 7 sections.<br />
1. General notes<br />
2. Structure of <strong>PRIMERGY</strong> <strong>SX30</strong><br />
3.1. <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel <strong>Configurator</strong><br />
3.2. <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster <strong>Configurator</strong><br />
3.3. <strong>SX30</strong> Cluster U320 <strong>Configurator</strong><br />
4. Upgrading the PRIMGERY <strong>SX30</strong><br />
5. Lines for <strong>PRIMERGY</strong> <strong>SX30</strong><br />
6. External Cabling for <strong>PRIMERGY</strong> <strong>SX30</strong><br />
7. Change report<br />
The configurator may include comments. Any instructions must be followed.<br />
For example, the comments may stipulate technical restrictions or exclusion criteria.<br />
The following instructions must be followed:<br />
Notation:<br />
For the sake of simplicity, references in some parts of the configurator omit the supplying works and<br />
no distinction is made between preinstalled components and loose shipment;<br />
hence SNP:SY-A1234x567, without E/L. ( E = preinstalled components; L = loose shipments)<br />
Legend:<br />
The number between the arrows on the left indicates the maximum number of times<br />
the relevant component can be ordered per system.<br />
Unless otherwise indicated, the configurator must be worked through once from start to finish, top to bottom.<br />
Further information in the internet see:<br />
http://www.primergy.com<br />
http://extranet.fujitsu-siemens.com/primergy<br />
(internet)<br />
(extranet)<br />
Prices and availability see price list and System-Architect.<br />
Subject to change and errors excepted.<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server 2 of 15
2. <strong>PRIMERGY</strong> <strong>SX30</strong> basic functions<br />
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
The external storage subsystem <strong>SX30</strong> is designed as a capacity extension for the <strong>PRIMERGY</strong> server family. It is completely adapted<br />
to the <strong>PRIMERGY</strong> family concerning design, HD technology, HD cage and integration into the <strong>PRIMERGY</strong> management concept.<br />
Current technology like SCSI Ultra320 and high disc capacity up to 2TByte (with up to 14 new 146GB HDs) in confined space<br />
(3 HU as Rack-version) are the outstanding properties of the subsystem. Two different versions for capacity extension (Single Node)<br />
and cluster solutions (Dual Node) are available.<br />
- Both versions of the <strong>PRIMERGY</strong> <strong>SX30</strong> subsystem are available in a 19'' rack version and a floorstand version.<br />
The <strong>PRIMERGY</strong> <strong>SX30</strong> takes only three height units (3 HU) in the rack.<br />
- The cabinet has two bays for redundant power supplies with hot-plug abilities. The hot-plug capability of the PS<br />
modules can only be used in a redundant arrangement.<br />
- A UPS is recommended for the use of the <strong>PRIMERGY</strong> <strong>SX30</strong>.<br />
- On default the subsystem is equipped with two redundant fans. They can be exchanged online without switching off the system.<br />
2.1. General configuration notes on storage subsystem <strong>PRIMERGY</strong> <strong>SX30</strong>:<br />
- Every power supply needs an external power cord. For the Rackversion 2 power cords are included in the rack<br />
installation kit. For the Floorstand version one country specific power cord must be ordered per installed power supply.<br />
- The 14 HD slide-in units are divided into two independent segments with 7 places each. A cascading of the two SCSI segments<br />
from one or several <strong>SX30</strong> is not possible.<br />
- The SCSI IDs of the hard discs are allocated automatically by the location.<br />
- The "Hot-Replace" function for HDs can only be used in conjunction with a corresponding RAID configuration (e.g. RAID Level 1/3/5).<br />
- <strong>PRIMERGY</strong> <strong>SX30</strong> operates internally and on the external lines exclusively with LVD signaling at a speed of Ultra320, Ultra160 or U2W SCSI.<br />
- Integration of the <strong>PRIMERGY</strong> <strong>SX30</strong> in ServerView and the use of RemoteView requires no additional components.<br />
The whole communication for server management is done over the SCSI buses to the SAF-TE section at the I/O-modules.<br />
- The subsystem <strong>PRIMERGY</strong> <strong>SX30</strong> does not supports a CAN bus!<br />
2.2. Configuration notes for <strong>PRIMERGY</strong> <strong>SX30</strong> capacity extension (Single Node)<br />
- One PS module is installed as standard. For redundancy a second PS module is needed (power cords see above).<br />
- Two SCSI Input modules are included in the <strong>PRIMERGY</strong> <strong>SX30</strong> basic version.<br />
Following RAID-Controllers are released (independent of the availability):<br />
* Mylex DAC960PRL (Tomcat) 1 channel U2W/LVD Order-No. : SNP:SY-F1961xxx-x **<br />
* Mylex Accele RAID 160 (Bobcat) 1 channel Ultra160 Order-No. : S26361-F2406-xxx **<br />
* Adaptec 2100 S 1 channel Ultra160 Order-No. : S26361-F2405-xxx **<br />
* Adaptec 2120 S 1 channel Ultra320 Order-No. : S26361-F2751-xxx<br />
LSI MegaRAID 320-1 1 Kanal Ultra320 Order-No. : S26361-F3005-xxx<br />
* DPT2664U3 2 channel Ultra160 Order-No. : SNP:SY-F2189xxx-x **<br />
* Mylex Accele RAID 352 2 channel Ultra160 Order-No. : S26361-F2569-xxx **<br />
* Adaptec 3200 S 2 channel Ultra160 Order-No. : S26361-F2385-xxx **<br />
* Adaptec 2200 S 2 channel Ultra320 Order-No. : S26361-F2752-xxx<br />
LSI MegaRAID 320-2 3 channel Ultra320 Order-No. : S26361-F3006-xxx<br />
LSI MegaRAID 320-2x 2 channel Ultra320 Order-No. : S26361-F3090-xxx<br />
* Mylex DAC1164P (Little Apple) 3 channel U2W/LVD Order-No. : SNP:SY-F1959xxx-x or F1960 **<br />
* Mylex EXR2000 (Big Apple) 4 channel Ultra160 Order-No. : SNP:SY-F2190xxx-x **<br />
* LSI MegaRAID 320-4x 4 channel Ultra320 Order-No. : S26361-F3007-xxx<br />
* withdrawn controllers<br />
** not released for Single Channel <strong>SX30</strong><br />
None-RAID SCSI-controllers and on-board SCSI-controllers are not supported.<br />
- Following HDs and combinations of these are released (independent of the availability):<br />
These HDs are released at all RAID-Controllers specified above.<br />
* 9GB, 7.200rpm Ultra160 Order-No. : SNP:SY-F2336E/L9-P<br />
* 18GB, 7.200rpm Ultra160 Order-No. : SNP:SY-F2336E/L18-P<br />
* 9GB, 10.000rpm Ultra160 Order-No. : SNP:SY-F2336E/L109-P<br />
* 18GB, 10.000rpm Ultra160 Order-No. : SNP:SY-F2336E/L118-P<br />
* 36GB, 10.000rpm Ultra160 Order-No. : SNP:SY-F2336E/L136-P<br />
* 73GB, 10.000rpm Ultra160 Order-No. : S26361-F2336-E/L173<br />
* 146GB, 10.000rpm Ultra160 Order-No. : S26361-F2336-E/L114<br />
* 18GB, 15.000rpm Ultra160 Order-No. : S26361-F2336-E/L518<br />
* 36GB, 15.000rpm Ultra160 Order-No. : S26361-F2336-E/L536<br />
* 73GB, 15.000rpm Ultra160 Order-No. : S26361-F2336-E/L573<br />
* 36GB, 10.000rpm Ultra320 Order-No. : S26361-F2764-E/L136<br />
73GB, 10.000rpm Ultra320 Order-No. : S26361-F2764-E/L173<br />
146GB,10.000rpm Ultra320 Order-No. : S26361-F2764-E/L114<br />
300GB,10.000rpm Ultra320 Order-No. : S26361-F2764-E/L130<br />
* 18GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L518<br />
36GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L536<br />
73GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L573<br />
146GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L514<br />
* 36GB, 10.000rpm Ultra320 Order-No. : S26361-F3121-E/L136<br />
73GB, 10.000rpm Ultra320 Order-No. : S26361-F3121-E/L173<br />
146GB,10.000rpm Ultra320 Order-No. : S26361-F3121-E/L114<br />
300GB,10.000rpm Ultra320 Order-No. : S26361-F3121-E/L130<br />
* 18GB, 15.000rpm Ultra320 Order-No. : S26361-F3121-E/L518<br />
36GB, 15.000rpm Ultra320 Order-No. : S26361-F3121-E/L536<br />
73GB, 15.000rpm Ultra320 Order-No. : S26361-F3121-E/L573<br />
146GB, 15.000rpm Ultra320 Order-No. : S26361-F3121-E/L514<br />
* withdrawn harddisks<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server 3 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
2.3. Configuration notes for <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster (Dual Node Ultra320)<br />
- The <strong>SX30</strong> Cluster-version (<strong>PRIMERGY</strong> <strong>SX30</strong> BU RH U320 Cluster) is only released and certified for Windows2000 Advanced Server<br />
and Windows Server 2003 Enterprise Edition with following systems: <strong>PRIMERGY</strong> RX/TX200, RX/TX300 and RX/TX600<br />
A weekly updated list with the certified server can be seen under:<br />
http://filestore.fsc.net/portal/portalb/uploads/Field%20Support/Certification/Status_of_cluster_certification.pdf<br />
In a cluster both servers must have an identical configuration. Independent of the used servers, a maximum of one <strong>SX30</strong><br />
subsystem is permissible.<br />
- To operate the <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster, the following RAID-controllers are released exclusively:<br />
LSI 2Channel 320-2 2 channel Ultra320 Order-No. : S26361-F3006-E128/L128<br />
1) The controller requires the SW-Kit V6.00-06 (FW: 1F30, driver: W2K mraid2k.sys 5.44, W2K3 mraid35x.sys 6.38.2.32)<br />
In the server TX200, TX300 and RX300 (S1 generation) is at least the BIOS version 1.08 necessary.<br />
- RAID-controllers for internal HDs (e.g. operating system HDs) are restricted to 1-channel (S26361-F3005-xxx) and 2-channel<br />
(S26361-F3006-xxx) from LSI and the Host-RAID-funktionality of the respective server released. Zero-channel RAID-controller<br />
from Adaptec in cluster-configurations are not released.<br />
- The basic versions for clustering includes already two PS modules for redundancy as standard (power cord, see above).<br />
- Also two Dual-SCSI Input modules are mounted as standard in the basic version of the <strong>SX30</strong> U320 Cluster.<br />
- <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster operates internally and on the external lines exclusively with LVD signaling at a speed of Ultra320.<br />
- Following HDs and combinations of these are released (independent of the availability):<br />
73GB, 10.000rpm Ultra320 Order-No. : S26361-F2764-E/L173<br />
146GB, 10.000rpm Ultra320 Order-No. : S26361-F2764-E/L114<br />
300GB,10.000rpm Ultra320 Order-No. : S26361-F3121-E/L130<br />
36GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L536<br />
73GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L573<br />
146GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L514<br />
2.4. Configuration notes for <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster (Dual Node Ultra320) under PRIMECLUSTER for Linux<br />
- The <strong>SX30</strong> Cluster-version (<strong>PRIMERGY</strong> <strong>SX30</strong> BU RH U320 Cluster) is applicable under Red Hat Enterprise Linux (RHEL) 2.1 and 3,<br />
as well as SuSE Linux Enterprise Server (SLES) 8 with all <strong>PRIMERGY</strong> Servers released for these Linux versions.<br />
A weekly updated list with the certified server can be seen under:<br />
http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/public/html/osrel_a.html<br />
In a cluster both servers must have an identical configuration. Independent of the used servers, a maximum of one <strong>SX30</strong><br />
subsystem is permissible.<br />
- To operate the <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster, the following RAID-controllers are released exclusively:<br />
LSI 2Channel 320-2<br />
1) The controller requires the megaraid driver versions aat least 1.19.6 (for SLES) and 1.18 (for RHEL).<br />
In the server TX200, TX300 and RX300 is at least the BIOS version 1.08 necessary.<br />
- RAID-controllers for internal HDs (e.g. operating system HDs) are restricted to 1-channel (S26361-F3005-xxx) and 2-channel<br />
(S26361-F3006-xxx) from LSI and the Host-RAID-funktionality of the respective server released. Zero-channel RAID-controller<br />
from Adaptec in cluster-configurations are not released.<br />
- The basic versions for clustering includes already two PS modules for redundancy as standard (power cord, see above).<br />
- Also two Dual-SCSI Input modules are mounted as standard in the basic version of the <strong>SX30</strong> U320 Cluster.<br />
- <strong>PRIMERGY</strong> <strong>SX30</strong> Cluster operates internally and on the external lines exclusively with LVD signaling at a speed of Ultra320.<br />
- Following HDs and combinations of these are released (independent of the availability):<br />
73GB, 10.000rpm Ultra320 Order-No. : S26361-F2764-E/L173<br />
146GB, 10.000rpm Ultra320 Order-No. : S26361-F2764-E/L114<br />
300GB,10.000rpm Ultra320 Order-No. : S26361-F3121-E/L130<br />
36GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L536<br />
73GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L573<br />
146GB, 15.000rpm Ultra320 Order-No. : S26361-F2764-E/L514<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server 4 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 2: Structure of the <strong>PRIMERGY</strong> <strong>SX30</strong><br />
<strong>SX30</strong> Structure<br />
Power<br />
Supplies<br />
SCSI Input<br />
Module<br />
Fan<br />
Unit<br />
SCSI Input<br />
Module<br />
Power<br />
Backplane<br />
Basic<br />
Chassis<br />
HDD<br />
Carrier<br />
<strong>SX30</strong>, rear view (with Single-SCSI-Input module)<br />
<strong>SX30</strong>, rear view (with Dual-SCSI-Input module)<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server 5 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 3.1: <strong>Configurator</strong> - <strong>PRIMERGY</strong> <strong>SX30</strong><br />
Page 1 Basic units and rack installation<br />
Start of "<strong>PRIMERGY</strong> <strong>SX30</strong>"<br />
External passive<br />
disk subsystem<br />
with Ultra320 Hostconnection<br />
Important!<br />
Reliable operation can only be<br />
guaranteed if only Fujitsu Siemens<br />
components are used.<br />
SNP:SY-K638V110-P<br />
SNP:SY-K638V210-P<br />
Basic Unit: 2-Channel Floorstand<br />
Basic Unit: 2-Channel Rack 3U<br />
Case incl.<br />
Case incl.<br />
- 2 x SCSI input modules - 2 x SCSI input modules Note:<br />
- 1 x 500W hot replace PS module - 1 x 500W hot replace PS module English/German documentation is<br />
- hot replace fan (N+1 redundant) - hot replace fan (N+1 redundant) enclosed in the basic units.<br />
- enclosure for 2 x 7 hot replace disk units - enclosure for 2 x 7 hot replace disk units<br />
PRIMECENTER Rack<br />
S26361-F2734-E20<br />
Bulk ware delivery of mounting kits:<br />
Mounting kit for <strong>PRIMERGY</strong> <strong>SX30</strong> / S60<br />
PRIMECENTER / DataCenter Rack<br />
- 1 pair of sliding rails (710-815mm) S26361-F2734-L20<br />
- 2 holders - 1 pair of sliding rails<br />
- 1 bracket PC-Rack - 2 holder<br />
- 1 cable management PC-racks - 1 bracket DC-PC-Rack<br />
- 2 power cords - 1 cable management<br />
Mounting kit for mounting of - 2 power cords<br />
servers in FSC 19" racks and all<br />
<strong>PRIMERGY</strong> 42/23U Rack<br />
server racks conforming to EIA<br />
Mounting kit for subsequent installation<br />
standard EIA-310-D for 19" racks.<br />
of a <strong>SX30</strong> in a <strong>PRIMERGY</strong> 42/23U Rack.<br />
Therefore the mounting kit is<br />
SNP:SY-F1331L102-P<br />
variable in deepth from 710-815mm - 1 pair of sliding rails<br />
The mounting kit is required for the - 2 holders<br />
mounting into <strong>PRIMERGY</strong> - 1 cable carrier<br />
PRIMECENTER-rack with 12, 24, 38 - 2 power cords<br />
or 46U (height units). Without this<br />
mounting kit the mounting into a<br />
<strong>PRIMERGY</strong> rack will not be possible.<br />
max. 1x per system<br />
SNP:SY-F1647E301-P<br />
Installation ex works for 1<br />
T26139-Y1742-L10<br />
server or subsystem<br />
For shipments to<br />
Hereby the rack will be delivered<br />
USA&Canada, you have<br />
completely pre-mounted and<br />
to order one power<br />
all wired connections are tested.<br />
cord (1,8m, grey) With racks 12U, 24U, 38U:<br />
per power supply. Systems and components "Rack-mounting ex factory"<br />
will be delivered installed in the rack<br />
This service is to be ordered once<br />
With racks 46U:<br />
per installable server / storage,<br />
Power cord for following countries: Systems and components in order to get the server / storage<br />
1.8m grey will be delivered separately subsystem mounted into the<br />
T26139-Y1740-E10 D, A, B, F, NL, FIN, N, S, E, To be ordered only together with <strong>PRIMERGY</strong> racks. In case of the 46 U<br />
P, RUS, TR a <strong>PRIMERGY</strong>- <strong>PRIMERGY</strong> Rack, this service has to<br />
T26139-Y1743-E10 Switzerland PRIMECENTER rack be ordered, to get the mounting<br />
T26139-Y1744-E10 United Kingdom, Ireland e.g.: kits and the cables installed.<br />
T26139-Y1745-E10 Italy S26361-K826-V10x<br />
T26139-Y1746-E10 Denmark refer configurator PC-Rack<br />
Per power supply a power cord must be ordered.<br />
max. 1x per System<br />
SNP:PS-F598E1-P<br />
Power Supply Module<br />
Occupies one bay for<br />
hot replace power supply<br />
max. 1x per unit<br />
T26139-Y1742-E10<br />
For shipments to USA&Canada, you<br />
have to order one power cord<br />
(1,8m, grey) per power supply.<br />
Redundancy and hot replace requires<br />
a second PS module in the <strong>SX30</strong>.<br />
For subsequent upgrade:<br />
SNP:PS-F598L1-P<br />
A<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server<br />
6 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 3.1: <strong>Configurator</strong> - <strong>PRIMERGY</strong> <strong>SX30</strong><br />
Page 2 Hard Disk Drive<br />
A<br />
Note:<br />
The new disk generation is only released for<br />
attachment to current U320 RAID controller<br />
S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130<br />
Hard disk 73GB in 1" carrier Hard disk 146GB in 1" carrier Hard disk 300GB in 1" carrier<br />
10000rpm,
Part 3.2: <strong>Configurator</strong> <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
Page 1 Basic units and rack installation<br />
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Start of "<strong>PRIMERGY</strong> <strong>SX30</strong>"<br />
External passive<br />
disk subsystem<br />
with Ultra320 Hostconnection<br />
Important!<br />
Reliable operation can only be<br />
guaranteed if only Fujitsu Siemens<br />
components are used.<br />
S26361-K638-V240<br />
Basic Unit: 1-Channel Rack 3U<br />
Case incl.<br />
Note:<br />
- 1 x SCSI input modules English/German documentation is<br />
- 1 x 500W hot replace PS module enclosed in the basic units.<br />
- hot replace fan (N+1 redundant)<br />
- enclosure for 1 x 14 hot replace disk units<br />
PRIMECENTER Rack<br />
S26361-F2734-E20<br />
Bulk ware delivery of mounting kits:<br />
Mounting kit for <strong>PRIMERGY</strong> <strong>SX30</strong> / S60<br />
PRIMECENTER / DataCenter Rack<br />
- 1 pair of sliding rails (710-815mm) S26361-F2734-L20<br />
- 2 holders - 1 pair of sliding rails<br />
- 1 bracket PC-Rack - 2 holder<br />
- 1 cable management PC-racks - 1 bracket DC-PC-Rack<br />
- 2 power cords - 1 cable management<br />
Mounting kit for mounting of - 2 power cords<br />
servers in FSC 19" racks and all<br />
<strong>PRIMERGY</strong> 42/23U Rack<br />
server racks conforming to EIA<br />
Mounting kit for subsequent installation<br />
standard EIA-310-D for 19" racks.<br />
of a <strong>SX30</strong> in a <strong>PRIMERGY</strong> 42/23U Rack.<br />
Therefore the mounting kit is<br />
SNP:SY-F1331L102-P<br />
variable in deepth from 710-815mm - 1 pair of sliding rails<br />
The mounting kit is required for the - 2 holders<br />
mounting into <strong>PRIMERGY</strong> - 1 cable carrier<br />
PRIMECENTER-rack with 12, 24, 38 - 2 power cords<br />
or 46U (height units). Without this<br />
mounting kit the mounting into a<br />
<strong>PRIMERGY</strong> rack will not be possible.<br />
max. 1x per system<br />
SNP:SY-F1647E301-P<br />
Installation ex works for 1<br />
server or subsystem<br />
Hereby the rack will be delivered<br />
completely pre-mounted and<br />
all wired connections are tested.<br />
With racks 12U, 24U, 38U:<br />
"Rack-mounting ex factory"<br />
Systems and components<br />
This service is to be ordered once<br />
will be delivered installed in the rack<br />
per installable server / storage,<br />
With racks 46U:<br />
in order to get the server / storage<br />
Systems and components<br />
subsystem mounted into the<br />
will be delivered separately<br />
<strong>PRIMERGY</strong> racks. In case of the 46 U<br />
To be ordered only together with<br />
<strong>PRIMERGY</strong> Rack, this service has to<br />
a <strong>PRIMERGY</strong>-<br />
be ordered, to get the mounting<br />
PRIMECENTER rack kits and the cables installed.<br />
e.g.:<br />
S26361-K826-V10x<br />
refer configurator PC-Rack<br />
max. 1x per System<br />
T26139-Y1742-E10<br />
For shipments to USA&Canada, you<br />
have to order one power cord<br />
(1,8m, grey) per power supply.<br />
SNP:PS-F598E1-P<br />
Power Supply Module<br />
Occupies one bay for<br />
hot replace power supply<br />
max. 1x per unit<br />
Redundancy and hot replace requires<br />
a second PS module in the <strong>SX30</strong>.<br />
For subsequent upgrade: SNP:PS-F598L1-P<br />
A<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server<br />
8 of 15
Part 3.2: <strong>Configurator</strong> <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
Page 2 Hard Disk Drive<br />
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
A<br />
S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130<br />
Hard disk 73GB in 1" carrier Hard disk 146GB in 1" carrier Hard disk 300GB in 1" carrier<br />
10000rpm,
Systemkonfigurator und Bestellinformationsleitfaden<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 3.3: <strong>Configurator</strong> - <strong>PRIMERGY</strong> <strong>SX30</strong>-Cluster (U320)<br />
Page 1 Basic units and rack installation<br />
Start of "<strong>PRIMERGY</strong> <strong>SX30</strong>"<br />
External passive cluster<br />
disk subsystem<br />
with Ultra320 Hostconnection<br />
Important!<br />
Reliable operation can only be<br />
guaranteed if only Fujitsu Siemens<br />
components are used.<br />
S26361-K638-V150<br />
S26361-K638-V250<br />
Basic Unit: 2-Channel Floorstand<br />
Basic Unit: 2-Channel Rack 3U<br />
Case incl. Case incl. Note:<br />
- 2 x Dual-SCSI input modules U320 - 2 x Dual-SCSI input modules U320 English/German documentation is<br />
- 2 x 500W hot replace PS module - 2 x 500W hot replace PS module enclosed in the basic units.<br />
- hot replace fan (N+1 redundant) - hot replace fan (N+1 redundant)<br />
- 2 x 7 hot replace disk units - 2 x 7 hot replace disk units<br />
PRIMECENTER Rack<br />
S26361-F2734-E20<br />
Bulk ware delivery of mounting kits:<br />
Mounting kit for <strong>PRIMERGY</strong> <strong>SX30</strong> / S60<br />
PRIMECENTER / DataCenter Rack<br />
- 1 pair of sliding rails (710-815mm) S26361-F2734-L20<br />
- 2 holders - 1 pair of sliding rails<br />
- 1 bracket PC-Rack - 2 holder<br />
- 1 cable management PC-racks - 1 bracket DC-PC-Rack<br />
- 2 power cords - 1 cable management<br />
Mounting kit for mounting of - 2 power cords<br />
servers in FSC 19" racks and all<br />
<strong>PRIMERGY</strong> 42/23U Rack<br />
server racks conforming to EIA<br />
Mounting kit for subsequent installation<br />
standard EIA-310-D for 19" racks.<br />
of a <strong>SX30</strong> in a <strong>PRIMERGY</strong> 42/23U Rack.<br />
Therefore the mounting kit is<br />
SNP:SY-F1331L102-P<br />
variable in deepth from 710-815mm - 1 pair of sliding rails<br />
The mounting kit is required for the - 2 holders<br />
mounting into <strong>PRIMERGY</strong> - 1 cable carrier<br />
PRIMECENTER-rack with 12, 24, 38 - 2 power cords<br />
or 46U (height units). Without this<br />
mounting kit the mounting into a<br />
<strong>PRIMERGY</strong> rack will not be possible. T26139-Y1742-E10 USA, Kanada<br />
max. 1x per system<br />
Netzleitung (1,8m, grau) je Netzteil einmal<br />
mitbestellen bei Lieferungen nach<br />
SNP:SY-F1647E301-P<br />
USA und Kanada.<br />
T26139-Y1742-L10 Installation ex works for 1<br />
For shipments to<br />
server or subsystem<br />
USA&Canada, you have<br />
Hereby the rack will be delivered<br />
to order one power<br />
completely pre-mounted and<br />
cord (1,8m, grey)<br />
all wired connections are tested.<br />
per power supply. With racks 12U, 24U, 38U: "Rack-mounting ex factory"<br />
Systems and components<br />
This service is to be ordered once<br />
will be delivered installed in the rack<br />
per installable server / storage,<br />
Power cord for following countries: With racks 46U: in order to get the server / storage<br />
1.8m grey Systems and components subsystem mounted into the<br />
T26139-Y1740-E10 D, A, B, F, NL, FIN, N, S, E, will be delivered separately <strong>PRIMERGY</strong> racks. In case of the 46 U<br />
P, RUS, TR To be ordered only together with <strong>PRIMERGY</strong> Rack, this service has to<br />
T26139-Y1743-E10 Switzerland a <strong>PRIMERGY</strong> be ordered, to get the mounting<br />
T26139-Y1744-E10 United Kingdom, Ireland PRIMECENTER-rack kits and the cables installed.<br />
T26139-Y1745-E10 Italy e.g.:<br />
T26139-Y1746-E10 Denmark S26361-K826-V10x<br />
refer configurator PC-Rack<br />
With the <strong>SX30</strong> Cluster 2 country specific<br />
max. 1x per System<br />
power cord are necessary.<br />
T26139-Y1742-E10<br />
For shipments to USA&Canada, you<br />
have to order one power cord<br />
(1,8m, grey) per power supply.<br />
A<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server<br />
10 von 15
Part 3.3: <strong>Configurator</strong> - <strong>PRIMERGY</strong> <strong>SX30</strong>-Cluster (Ultra 320)<br />
Page 2 Hard Disk Drive<br />
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
A<br />
S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130<br />
Hard disk 73GB in 1" carrier Hard disk 146GB in 1" carrier Hard disk 300GB in 1" carrier<br />
10000rpm,
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 4: Upgrading the <strong>PRIMERGY</strong> <strong>SX30</strong><br />
The modular concept of <strong>PRIMERGY</strong> <strong>SX30</strong> enables various upgrades (later also the upgrade from single node to dual-node).<br />
The upgrade is done by adding different components. This can partly be done online by the user.<br />
Adding a second redundant power supply<br />
The Upgrade kit SNP:PS-F598E1-P, a second redundant power supply, can be added.<br />
The upgrade does not include any power cords.<br />
Passive-cluster basic variations of <strong>SX30</strong> are already containing 2 power supplies. An upgrade is not possible.<br />
Every power supply needs an external power connection.<br />
To upgrade a <strong>SX30</strong> to a <strong>SX30</strong> U320 passive cluster variation<br />
By exchanging both SCSI-Input modules by two U320 Dual-SCSI-Input modules (S2361-F2360-L2 ,<br />
this part number contains only 1 dual SCSI input modules, therefore it must be ordered 2 times.)<br />
the subsystem <strong>SX30</strong> can be upgraded later for a U320 passive-cluster use. In this case you have to consider<br />
that the <strong>SX30</strong> cluster variation is only released with 2 power supplies. If only one power supply exists,<br />
you have to order a second one: SNP:PS-F598L1-P.<br />
Also with upgrades, you've got to be aware the notes under "1. <strong>PRIMERGY</strong> <strong>SX30</strong> General Notes".<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server<br />
12 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 5: Lines for connecting the <strong>PRIMERGY</strong> <strong>SX30</strong> to a server<br />
For selecting the external cables see also overview of SCSI cables (part 6)<br />
External LVD SCSI cables<br />
cables for connecting HDs to the server<br />
without installation ex works<br />
External LVD SCSI cable 2.0m SNP:SY-F2365L20-P<br />
External LVD SCSI cable 5.0m SNP:SY-F2365L50-P<br />
installation ex works<br />
External LVD SCSI cable<br />
(length customized for DataCenter Rack)<br />
SNP:SY-F2365E500-P<br />
The cables SNP:SY-F2365 have on both sides a threaded 68pin VHDCI connector.<br />
("Very High Density Cable Interconnect" UHD68(S), also named: VHDCI).<br />
If the 10m cable is absolute necessary, you can use following cable: D:GPDS2-KB10<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server<br />
13 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Part 6: External SCSI cabling between <strong>PRIMERGY</strong> Server and <strong>PRIMERGY</strong> <strong>SX30</strong><br />
<strong>PRIMERGY</strong> Server cable no. lengths <strong>PRIMERGY</strong> <strong>SX30</strong><br />
RAID Controller<br />
2,0 m 5.0 m 10.0 m<br />
On Board RAID (RX300 S2 only)<br />
LSI MegaRAID ROMB<br />
1 channel Ultra320<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
F3091 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
1 channel RAID Controller<br />
withdrawn product<br />
Mylex DAC960PRL<br />
1 channel U2W/LVD<br />
F1961 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
withdrawn product<br />
Adaptec 2100<br />
1 channel Ultra160<br />
F2405 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
withdrawn product<br />
Mylex AcceleRAID 160<br />
1 channel Ultra160<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
F2406 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
withdrawn product<br />
Adaptec 2120<br />
1 channel Ultra320<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
F2751 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
withdrawn product<br />
LSI MegaRAID 320-1<br />
1 channel Ultra320 <strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
F3005 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
2 channel RAID Controller<br />
withdrawn product<br />
DPT 2664U3<br />
2 channel Ultra160 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
F2189 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
withdrawn product<br />
Adaptec 3200<br />
2 channel Ultra160 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
F2385 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Dual-Node U160<br />
withdrawn product<br />
Mylex AcceleRAID 352<br />
withdrawn product<br />
2 channel Ultra160 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
F2569 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
Attention: max. 5m cable length<br />
Adaptec 2200<br />
2 channel Ultra320 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
F2752 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
Cluster Controller<br />
LSI MegaRAID 320-2<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
1 channel Ultra320 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
F3006 ¥ SNP:SY-F2365 L20-P L50-P ¥ <strong>PRIMERGY</strong> <strong>SX30</strong> Dual-Node U320<br />
LSI MegaRAID 320-2x<br />
1 channel Ultra320<br />
F3090<br />
3 channel RAID Controller<br />
withdrawn product<br />
Mylex DAC1164P<br />
3 channel U2W/LVD<br />
F1959 / F1960<br />
¥ SNP:SY-F2365 L20-P L50-P ¥<br />
¥ SNP:SY-F2365 L20-P L50-P ¥<br />
¥ SNP:SY-F2365 L20-P L50-P ¥<br />
¥ SNP:SY-F2365 L20-P L50-P ¥<br />
¥<br />
4 channel RAID Controller<br />
withdrawn product<br />
Mylex EXR2000 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
Big Apple ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
4 channel U160 ¥ SNP:SY-F2356 L20-P L50-P ¥<br />
F2190 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
withdrawn product<br />
¥ SNP:SY-F2365 L20-P L50-P ¥<br />
LSI MegaRAID 320-4x<br />
¥ SNP:SY-F2365 L20-P L50-P ¥<br />
4 channel Ultra320<br />
¥ SNP:SY-F2356 L20-P L50-P ¥<br />
F3007 ¥ SNP:SY-F2365 L20-P L50-P ¥<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
Attention: max. 5m cable length<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Single-Node<br />
UHD68(S), also: VHDCI connector, 68-pin<br />
There is no CAN-Bus connection from the <strong>PRIMERGY</strong> <strong>SX30</strong> to the Server necessary and it will not be supported.<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server<br />
14 of 15
System configurator and order-information guide<br />
<strong>PRIMERGY</strong> <strong>SX30</strong> Status 2008-04-28<br />
Changereport<br />
Version Date Changes<br />
2007-03-01 SCSI Hard disk 300GB - now available<br />
2006-03-02 Hard disk and controller list updated<br />
2005-05-18 Hard disks without carrier - no longer available<br />
2005-05-18 Hard disk 146GB in 1" carrier U320 SCSI 15.000rpm - now available<br />
2005-04-20 HDD's 18GB 15.000 rpm - no longer available<br />
2005-03-16 HDD's 36GB 10.000 rpm. - no longer available<br />
2005-02-14 new disk generation added, for <strong>PRIMERGY</strong> <strong>SX30</strong> Single Channel and Cluster U320, too<br />
V2.13 2004-11-19 new disk generation added<br />
V2.12 2004-06-25 new LSI RAID controllers 1 and 4 channel added<br />
2004-02-16 U160 Cluster variants - no longer available<br />
2003-12-19 All hard disk's U160 SCSI (160 MB/sec) - no longer available<br />
2003-11-12 <strong>SX30</strong> Cluster (U320) - now available<br />
V2.11 2003-09-25 <strong>SX30</strong> Single Channel and U320 RAID-Controller added<br />
2003-06-25 Cable 10m SNP:SY-F2365L100-P - no longer available<br />
2003-06-24 Hard disk's Ultra 320 SCSI (320MB/s) - now available<br />
2003-05-13 Power cord for USA, Canada, 1x per power supply - L10 for Floorstand, E10 for Rack Basic Unit suitable<br />
2003-04-25 Hard disk 73 GB 15000rpm, U160 SCSI - now available<br />
V2.10 2003-03-18 <strong>PRIMERGY</strong> S30 in <strong>PRIMERGY</strong> <strong>SX30</strong> renamed<br />
2003-01-22 Hard disk 146GB 10000rpm - now available<br />
2002-12-13 Option "no powercord" - no longer available<br />
2002-12-13 Country Power Cord for USA, Canada - no longer available<br />
2002-09-26 Option "no powercord" - now available<br />
V2.03 2002-08-12 Mountingkit for DataCenter Rack is no longer available<br />
10m SCSI-connection cable is no longer available<br />
V2.02 2002-07-03 Power cord for USA, Canada - now available<br />
2002-05-16 S26361-F2734-E20 - Mounting kit for <strong>PRIMERGY</strong> S30 / S60 added<br />
V2.01 2002-04-22 Modification of configuration hints in chapter 2.2 and 2.3<br />
addition of a S30 SCSI-cable in part 6<br />
- SNP:SY-F2365<br />
V2.0 2001-10-16 Cluster variations available<br />
2002-01-22 Hard disk 36GB, 15000rpm - as soon as available<br />
2001-09-10 Installation in Standard 19" Rack at factory is no longer available<br />
V1.6 2001-08-09 Hard Disks 7.200rpm - no longer available<br />
Hard Disk 73 GB 10.000rpm, now available<br />
V1.5 2001-05-16 4-channel RAID controller and 2 channel RAID controller released.<br />
V1.4 2001-04-18 Country pack - no longer available<br />
Power cord for floorstand has to be ordered separately.<br />
V1.3 2000-12-19 Country packs reduced to one international pack<br />
Now possible to order S30 without hard disks<br />
new 15.000 rpm hard disc added.<br />
V1.2 2000-11-14 some error fixed, new RAID-controllers added<br />
V1.1 2000-07-05 National accessories packages: product numbers corrected<br />
V1.0 2000-05-23 first version in the intranet<br />
Fujitsu Siemens Computers Enterprise Products - <strong>PRIMERGY</strong> Server 15 of 15