<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong><br />

System configurator and order-information guide<br />

May 2006<br />

Contents<br />

Instructions<br />

Configuration<br />

diagram<br />

Configurator<br />

0 System software<br />

I Basic unit<br />

I I Processor<br />

I I I Memory<br />

I V Hard disk drives / Tapes<br />

V SCSI / RAID controller<br />

VI Fibre Channel controller<br />

VII Communication / Network<br />

V I I I System Management Products (RemoteView)<br />

I X Miscellaneous<br />

X Power cords<br />

Change<br />

report<br />

<strong>PRIMERGY</strong> Server


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Instructions<br />

This document contains basic product and configuration information that will enable you to configure your system via<br />

P C - / S y s t e m - A r c h i t e c t .<br />

Only these tools will ensure a fast and proper configuration of your <strong>PRIMERGY</strong> server or your complete<br />

P R I M E R G Y R a c k s y s t e m .<br />

You can configure your individual <strong>PRIMERGY</strong> server in order to adjust your specific requirements.<br />

The System configurator is divided into several chapters that are identical to the current price list and PC-/ System-Architect<br />

Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through<br />

the configurator by following the lines from the top to the bottom.<br />

Section III Memory, example<br />

There are X memory slots which can be equipped with XXX MB.<br />

It is permissible to make up to X passes through the memory upgrade options.<br />

X<br />

times<br />

S26361-XXX-XXX<br />

S26361-XXX-XXX<br />

Memory XXX MB Memory XXX MB<br />

max. X times per system max. X times per system<br />

In one chapter you can only select as many components (here 4x) as the arrow indicates. 4x<br />

Please note that there are information symbols which indicate necessary information.<br />

Further information in the internet see:<br />

http://www.primergy.com<br />

http://extranet.fujitsu-siemens.com/primergy<br />

(internet)<br />

(extranet)<br />

Prices and availability see price list and PC-/ System-Architect<br />

Subject to change and errors excepted<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 2 of 16


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

TOP View<br />

Configuration diagram <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong><br />

System unit ( I )<br />

Slot<br />

Extension slots Memory ( III )<br />

SCSI / RAID controller ( V )<br />

Fiber Channel ( VI )<br />

Memory Board A<br />

Communication/Network ( VII )<br />

(2 Banks / 4 modules)<br />

7<br />

6<br />

5<br />

PCI-X 64-Bit / 100MHz, long<br />

PCI-X 64-Bit / 100MHz, long<br />

PCI-Express x4 ( hot-plug )<br />

Memory Board B<br />

(2 Banks / 4 modules)<br />

Memory Board C<br />

(2 Banks / 4 modules)<br />

Memory Board D<br />

(2 Banks / 4 modules)<br />

4<br />

3<br />

2<br />

1<br />

PCI-Express x4 ( hot-plug )<br />

PCI-Express x4 ( hot-plug )<br />

PCI-X 64-Bit / 133MHz, long ( hot-plug )<br />

PCI-Express x8 ( hot-plug )<br />

Processors must be plugged<br />

in order according the picture.<br />

Processor ( II )<br />

Xeon<br />

MP 3<br />

Xeon<br />

MP 4<br />

Xeon<br />

MP 2<br />

Xeon<br />

MP 1<br />

Operating Panel<br />

FRONT VIEW<br />

Operating<br />

Panel<br />

Video<br />

Accessible drives<br />

5.25"x 0.5" bay for CD/DVD<br />

Local View LCD Display<br />

Tape drives ( IV )<br />

USB<br />

USB<br />

USB<br />

Hard disk drives ( IV ) hot-plug<br />

Channel A Channel B<br />

3.5"x1" SCSI-ID 4 3.5"x1" SCSI-ID 4<br />

3.5"x1" SCSI-ID 3<br />

3.5"x1" SCSI-ID 3<br />

3.5"x1" SCSI-ID 2 3.5"x1" SCSI-ID 2<br />

5.25"x1.6" Tape Drive 3.5"x1" SCSI-ID 1 3.5"x1" SCSI-ID 1<br />

5.25"x1.6" Tape Drive 3.5"x1" SCSI-ID 0 3.5"x1" SCSI-ID 0<br />

COM<br />

Video<br />

USB<br />

USB<br />

Ether<br />

net<br />

Ether<br />

net<br />

REAR VIEW<br />

Hot Plug Redundant Power Supply<br />

1 . P S U 2 . P S U<br />

Key:<br />

Included in basic unit<br />

Option<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 3 of 16


System configurator and order-information guide<br />

Start "<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong>" <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

SW Configurator 32 bit<br />

with OEM-Software<br />

without OEM-Software<br />

for <strong>PRIMERGY</strong> Server Usage of OEM SW from MS is for <strong>PRIMERGY</strong> Server<br />

not possible under ESX or GSX<br />

Later use of OEM operating system<br />

VMware-Software as soon as available software is not allowed,<br />

- VCMS VirtualCenter Management Server apart from few VMware<br />

- ESX Server and ESX Virtual Infrastructure Node add-ons<br />

- P2V Assistant Enterprise Edition<br />

For all SW products please refer to the corresponding software configurator accessible via<br />

the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.<br />

MS - Software: W **) PRIMECLUSTER *)<br />

- Windows 2000 Server - Clustering<br />

- Windows 2000 Advanced Server - Load Balancing<br />

- Windows Server 2003,<br />

Standard<br />

Edition<br />

Enterprise Edition Linux - Software: L **)<br />

- Additional loose - SuSE Linux Enterprise Server<br />

Client-Access-Licenses (CALs) - Red Hat Enterprise Linux<br />

(not for Web Edition)<br />

CITRIX-Software for<br />

Windows: W-MF<br />

- Presentation Server<br />

LoadBalancing<br />

Additional User Licences<br />

MultiPath, Duplex Data Manager (DDM)<br />

W2K; W2K3 Linux (W-DDM)<br />

Adaptive Services Control Center (ASCC)<br />

Details eg. version numbers are published<br />

ASCC Satellite Node in the separate SW-Configurator<br />

SLES<br />

Manageability Software: V<br />

- RemoteView Software<br />

- RemoteView Service Board<br />

Backup-Software /<br />

Application-Software: U<br />

- ARCserve<br />

- openSM2<br />

*) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under<br />

http://extranet.fujitsu-siemens.com/primecluster<br />

**) Pay attention to the release and ordering information in PRINCE -> Operating System<br />

http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm<br />

Find detailed software configurators and release lists (OS-matrix / system management) under following addresses:<br />

for internal users:<br />

for partners:<br />

http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm<br />

http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm<br />

Continue with <strong>PRIMERGY</strong><br />

HW configurator<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 4 of 16


System configurator and order-information guide<br />

Start "<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong>" <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

SW Configurator EM64T<br />

with OEM-Software<br />

without OEM-Software<br />

for <strong>PRIMERGY</strong> Server for <strong>PRIMERGY</strong> Server<br />

Later use of OEM operating<br />

For all SW products please refer to the corresponding system software is not allowed!<br />

software configurator accessible via the Extranet under<br />

"Configuration & Tools, -All configurations, -Software,<br />

URL see below.<br />

as soon as available<br />

Microsoft - Software: W Linux - Software: L *) **)<br />

only - Windows Server 2003, only - SuSE Linux Enterprise Server<br />

EM64T x64 Standard Edition EM64T - Red Hat Enterprise Linux<br />

x64 Enterprise Edition<br />

- Additional loose<br />

Client-Access-Lizenzen<br />

(CALs)<br />

CITRIX-Software for<br />

only Windows: W-MF<br />

EM64T - Presentation Server<br />

LoadBalancing<br />

Additional User Licences<br />

only MultiPath, Duplex Data Manager (DDM)<br />

EM64T Windows, Linux (W-DDM)<br />

Details eg. version numbers are published<br />

Manageability Software: V**)<br />

in the separate SW-Configurator<br />

only - RemoteView Software<br />

EM64T - RemoteView Service Board<br />

- RemoteView Diagnosis *) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under<br />

http://extranet.fujitsu-siemens.com/primecluster<br />

**) Pay attention to the release and ordering information in PRINCE -> Operating System<br />

http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm<br />

You'll find single software configurators and release lists (OS-matrix / system management / security) under following addresses:<br />

for internal users:<br />

for partners:<br />

http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htm<br />

http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm<br />

Continue with <strong>PRIMERGY</strong><br />

HW configurator<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 5 of 16


System configurator and order-information guide<br />

Start <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section I Basic unit<br />

<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Basic Unit including:<br />

- 2 hot-plug power supply (redundant)<br />

Floorstand-version Rack-version - 6 hot-plug fans (redundant)<br />

Basic unit with: Basic unit with: - 5 + 5 bays for 1" HDD`s (two channels)<br />

- 1x XEON MP processor (max. 4) - 1x XEON MP processor (max. 4) - 1 bay (0,5" height) for CD- or DVD-ROM<br />

with 667/800MHz Frontside Bus with 667/800MHz Frontside Bus - 2x 5.25" bays FH (1.6" high) for accessible drives<br />

- USB Mouse with two push buttons - Rack Mounting Kit<br />

- Floorstand kit with lockable front door - LCD-Display for LocalView Systemboard with<br />

- 2x power cord with 16A Schuko - 2x power cord with 10A IEC320 C14 - Intel E8501 chipset<br />

(S26361-F3151-E100) (S26361-F3151-E350) - One 64bit Xeon MP CPU (2nd, 3rd and 4th as option)<br />

- memory of basic units selectable via - memory of basic units selectable via - 7 PCI Slots<br />

base memory order codes base memory order codes - 1x 64bit / 133MHz PCI-X slot (hot plug)<br />

3.16GHz / 1MB SLC S26361-K989-V112 3.16GHz / 1MB SLC S26361-K989-V512 - 2x 64bit / 100MHz PCI-X slot<br />

3.66GHz / 1MB SLC S26361-K989-V122 3.66GHz / 1MB SLC S26361-K989-V522 - 3x PCIe x4 slot (hot plug)<br />

2.67GHz/2MB 7020 S26361-K989-V312 2.67GHz/2MB 7020 S26361-K989-V712 - 1x PCIe x8 slot (hot plug)<br />

2.80GHz/2MB 7030 S26361-K989-V322 2.80GHz/2MB 7030 S26361-K989-V722<br />

3.00GHz/4MB 7041 S26361-K989-V332 3.00GHz/4MB 7041 S26361-K989-V732 - 1 memory board (2nd, 3rd and 4th as option)<br />

- Ultra 320 SCSI-controller (LSI 53C1030)<br />

- onboard RAID 5 functionality with 256MB Cache<br />

(RAID BBU optional)<br />

- Dual LAN-Controller 1GBit on-board<br />

WOL-capable (BroadCom 5704)<br />

- VGA Controller on-board<br />

(ATI Radeon 7000M, 16MB RAM)<br />

Power cables must be order seperatly, - Server Management Controller on-board<br />

see section "X Power Cords" (RSB 2 Board optional)<br />

- ServerStart packet incl. ServerBooks CD,<br />

ServerSupport CD and ServerView<br />

External Interfaces:<br />

Front<br />

side<br />

<strong>PRIMERGY</strong> PRIMECENTER- Rack "Rack-mounting ex factory" 3x USB 2.0<br />

This service is to be ordered once 1x VGA (15 pin)<br />

per installable server/storage<br />

SNP:SY-F1647E301-P subsystem, in order to get the Rear Side<br />

Installation ex works for one server/storage subsystem 2x USB 2.0<br />

server or subsystem. mounted into the <strong>PRIMERGY</strong> racks. 1x VGA (15 pin)<br />

Hereby the rack will be delivered In case of the 46 U <strong>PRIMERGY</strong> rack, 1x RS-232-C (serial, 9 pin)<br />

completely pre-mounted and this service has to be ordered, 2x RJ45 (on board LAN)<br />

all wired connections are tested. to get the mounting kits and the no PS/2 connection for KB / Mouse<br />

With racks 12U, 24U, 38U: cables installed (USB connectivity must be used instead)<br />

Systems and components<br />

will be delivered installed in the rack<br />

With racks 46U: Rack Mounting kit is part of the basic unit <strong>PRIMERGY</strong> <strong>TX600</strong> S2 Rack<br />

Systems and components - 1 pair of telescopic rails (713 - 812mm)<br />

will be delivered separately - 1 bracket DC-PC-Rack<br />

To be ordered only together with - 1 cable management for DC-PC-racks<br />

a <strong>PRIMERGY</strong>- This kit allows for mounting of TX/RX600 S2 in in FSC 19" DataCenter- and<br />

PRIMECENTER rack PRIMECENTER- racks and all server racks conforming to EIA standard EIA-310-D for 19" racks.<br />

e . g . : Therefore the mounting kit is variable in depth from 713 - 812mm<br />

S26361-K826-V10x Installation in <strong>PRIMERGY</strong> 19" Classic rack is not possible.<br />

refer configurator DC-Rack Due to the heat dissipation of the system, sufficent cooling couldn´t be enabled in classic rack.<br />

max. 1x per System<br />

Connetion for KVM switch / Rack console<br />

- RC23 can be directly connected (both USB and PS/2 connections)<br />

- KVM S2 series needs the KVM S2 Adapter USBVGA<br />

- For ES4/8+ KVM series with PS/2 connector as well as for standard PS/2 KB / Mouse<br />

an additional USB to PS/2 adapter must be bought additionally and connected to the <strong>TX600</strong> S2.<br />

The adapter offers 2x PS/2 ports.<br />

Adaper order number, to purchase via PRIMEPOWER, is:<br />

D:GP70P-KA01 Adapter for PS/2USB<br />

- Appropriate FSC USB keyboard is S26381-K340-V1*<br />

This keyboard also needs USB cable T26139-Y3812-V1<br />

A<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 6 of 16


System configurator and order-information guide<br />

A <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section II Processor<br />

A 4-way processor system requires a multi-processor operating system<br />

Later upgrading to a four-way-processor system is also possible<br />

VRM´s for 1st/2nd CPU are on the Motherboard, for the 3nd / 4th CPU addition VRM Modules are required.<br />

Extension CPUs must have identical cache size and clock rate<br />

S26361-F3124-E311<br />

S26361-F3124-E361<br />

XEON MP 3.16GHz XEON MP 3.66GHz<br />

with 1 MB SLC on Chip, with 1MB SLC on Chip,<br />

heat sink and "Easy retention" heat sink and "Easy retention"<br />

occupies socket for one CPU occupies socket for one CPU<br />

max. 3x per system max. 3x per system<br />

S26361-F3124-E262 S26361-F3124-E282 S26361-F3124-E304<br />

XEON MP 7020 2.67GHz XEON MP 7030 2.80GHz XEON MP 7041 3.00GHz<br />

667 MHz FSB 800 MHz FSB 800 MHz FSB<br />

with 2x 1MB SLC on Chip, with 2x 1MB SLC on Chip, with 2x 2MB SLC on Chip,<br />

heat sink and "Easy retention" heat sink and "Easy retention" heat sink and "Easy retention"<br />

occupies socket for one CPU occupies socket for one CPU occupies socket for one CPU<br />

max. 3x per system max. 3x per system max. 3x per system<br />

S26361-F3124-E200<br />

VRM modules for 3rd/4th CPU<br />

max. 1x per system<br />

S26361-F3124-E311<br />

S26361-F3124-E361<br />

XEON MP 3.16GHz XEON MP 3.66GHz<br />

with 1 MB SLC on Chip, with 1MB SLC on Chip,<br />

heat sink and "Easy retention" heat sink and "Easy retention"<br />

occupies socket for one CPU occupies socket for one CPU<br />

up to max. 3x per system max. 3x per system<br />

2x<br />

S26361-F3124-E262 S26361-F3124-E282 S26361-F3124-E304<br />

XEON MP 7020 2.67GHz XEON MP 7030 2.80GHz XEON MP 7041 3.00GHz<br />

667 MHz FSB 800 MHz FSB 800 MHz FSB<br />

with 2x 1MB SLC on Chip, with 2x 1MB SLC on Chip, with 2x 2MB SLC on Chip,<br />

heat sink and "Easy retention" heat sink and "Easy retention" heat sink and "Easy retention"<br />

occupies socket for one CPU occupies socket for one CPU occupies socket for one CPU<br />

max. 3x per system max. 3x per system max. 3x per system<br />

B<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 7 of 16


System configurator and order-information guide<br />

B <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section III Memory<br />

The system can be equipped with up 4 memory boards with 2 memory banks each.<br />

One Memory Board is allready supplied in the base unit.<br />

Each memory board can be equipped with up to 2x 8GB = 16GB memory.<br />

The maximal extension is 64GB with 4GB modules!<br />

No mix of modules within one memory bank is allowed.<br />

For each basic unit, one pair of memory modules has to be ordered with the ordercode of "Base Memory"<br />

(either 2GB = 2x1GB, 4GB = 2x2GB or 8GB = 2x4GB)<br />

Note**: The price of the smallest Base Memory is already included in the basic unit,<br />

The price of the other Base Memories is the Delta to the smallest Base Memory<br />

Additional memory extensions (Upgrade Memory) can still be configured for the standard market price.<br />

ECC with memory scrubbing function is standard for <strong>TX600</strong> <strong>S3</strong>.<br />

Optional hot-spare memory functionality can be configured in the BIOS (redundant memory bank n + 1)<br />

RX600 <strong>S3</strong> supports the memory protection through Memory Mirroring or Memory RAID.<br />

Memory Mirroring requires 2 or 4 Memory boards, Memory RAID requires 4 Memory boards.<br />

see Note** above<br />

S26361-F3072-B622 S26361-F3072-B623 S26361-F3072-B624<br />

Base memory 2 GB Base memory 4 GB Base memory 8 GB<br />

DDR RAM PC2-3200 ECC DDR RAM PC2-3200 ECC DDR RAM PC2-3200 ECC<br />

with chipkill support with chipkill support with chipkill support<br />

consisting of 2 modules consisting of 2 modules consisting of 2 modules<br />

with 1 GB each with 2 GB each with 4 GB each<br />

occupies one bank occupies one bank occupies one bank<br />

max. 1x per base system max. 1x per base system max. 1x per base system<br />

S26361-F3072-E622 S26361-F3072-E623 S26361-F3072-E624<br />

Upgrade memory 2 GB Upgrade memory 4 GB Upgrade memory 8 GB<br />

DDR RAM PC2-3200 ECC DDR RAM PC2-3200 ECC DDR RAM PC2-3200 ECC<br />

with chipkill support with chipkill support with chipkill support<br />

consisting of 2 modules consisting of 2 modules consisting of 2 modules<br />

with 1 GB each with 2 GB each with 4 GB each<br />

occupies one bank occupies one bank occupies one bank<br />

max. 1x per base system max. 1x per base system max. 1x per base system<br />

S26361-F3125-E130<br />

Memory Board with 2 banks<br />

for 2 modules each<br />

max. 3x per system<br />

up<br />

to<br />

3x S26361-F3072-E622 S26361-F3072-E623 S26361-F3072-E624<br />

Upgrade memory 2 GB Upgrade memory 4 GB Upgrade memory 8 GB<br />

DDR RAM PC2-3200 ECC DDR RAM PC2-3200 ECC DDR RAM PC2-3200 ECC<br />

with chipkill support with chipkill support with chipkill support<br />

consisting of 2 modules consisting of 2 modules consisting of 2 modules<br />

with 1 GB each with 2 GB each with 4 GB each<br />

occupies one bank occupies one bank occupies one bank<br />

max. 2x per memory board max. 2x per memory board max. 2x per memory board<br />

C<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 8 of 16


System configurator and order-information guide<br />

C <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section IV Hard disk drives / Tapes<br />

Alternatives for cabling of the onboard SCSI controller of <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong><br />

Picture 1: Picture 2: Picture 3:<br />

Two channels for Disks One ch. for Disks + int. Tape One ch. for Disks + ext. Tape<br />

1x5 1x5 1x5<br />

onboard HDD onboard HDD onboard HDD<br />

SCSI / RAID SCSI / RAID SCSI / RAID<br />

1x5 internal ext.<br />

HDD Tapes SCSI Devices<br />

Configuration with 2 channels for Disk Drives Picture 1<br />

Both channels of the on-board SCSI/RAID-controller are used for SCSI disk drives (pls see pictures above).<br />

For the connetion of internal tape devices an additonal SCSI controller is required, pls see section V SCSI-RAID controller<br />

Configuration with 2 channels for Disk Drives plus internal Tape device Picture 2<br />

One channel of the on-board SCSI/RAID-controller is used for SCSI disk drives (pls see pictures above).<br />

The secound channel can be used to connect additional SCSI drives drives and /or an internal tape device.<br />

Configuration with 1 channels for Disk Drives plus external Tape device Picture 3<br />

One channel of the on-board SCSI/RAID-controller is used for SCSI HDD (pls see pictures above).<br />

The secound channel can be used to connect external Tape drives.<br />

Additional options with 29160 SCSI Controller<br />

optional optional optional<br />

internal<br />

internal<br />

Tape Devices Tape Devices<br />

29160 Contr. 29160 Contr. 29160 Contr. ext.<br />

internal Tape Devices<br />

Tape<br />

Devices<br />

29160 Contr. 29160 Contr. ext. 29160 Contr. ext.<br />

Tape Devices Tape Devices<br />

One of the following USB devices must be used for integrating the drivers during installation<br />

process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:<br />

1 ) U S B D V D + - R W : S26391-F3152-L300<br />

Traveller III DVD DL super multi drive (USB cable included)<br />

2) FDD USB (external): S26391-F264-L226<br />

external USB FDD (USB cable included)<br />

3) USB Keyboard: S26381-K340-V120<br />

KBPC PX D, professional keyboard<br />

4) USB Mouse: S26381-K403-L100<br />

Optical Wheel Mouse<br />

5) USB Memorybird: S26391-F6046-L24<br />

Memorybird<br />

1GB<br />

Additionally a monitor can be connected to the VGA 15-pin interface.<br />

D<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 9 of 16


System configurator and order-information guide<br />

D <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

S26361-F3123-E1<br />

S26361-F3236-E1<br />

CD-RW / DVD drive 0.5" DVD-RW 8x super multi drive<br />

24/24/24x / 8x ATAPI all formats, DUAL/DL, DVD-RAM<br />

1x CD-RW only with W2K, W3K, Linux only W2K, W3K and Linux<br />

0.5 x 5.25", anthracite bezel 0.5 x 5.25", anthracite bezel<br />

max. 1x per system max. 1x per system<br />

S26361-F3128-E101<br />

internal SCSI-Cable For the 1st tape drive<br />

for connetion of<br />

internal Tape devices<br />

max. 1x per system<br />

S26361-F3158-E3<br />

Tape drive LTO3 Ultrium<br />

400GB, 80MB/s, U160 SCSI<br />

Connector:<br />

HD68<br />

1x without cable<br />

incl. description (Ger/US)<br />

data and cleaning cartridge<br />

3.2 x 5.25", anthracite bezel<br />

max. 1x per system<br />

S26361-F2848-E3 S26361-F2849-E3 S26361-F3224-E3 S26361-F3157-E3<br />

Tape drive DDS Gen5 Tape drive VXA-2 Tape drive VXA-320 Tape drive LTO2HH Ultrium<br />

S26361-F2848-E31 (only for OBDR) 80GB, 6MB/s, U2W SCSI 160GB, 12MB/s, U160 SCSI 200GB, 24MB/s, U160 SCSI<br />

DDS-G5 for One buttom dis. recov. Connector: HD68 Connector: HD68 Connector: HD68<br />

1x 36GB, 3MB/s, U2W SCSI without cable without cable without cable<br />

Connector: HD68 incl. description (Ger/US) incl. description (Ger/US) incl. description (Ger/US)<br />

Up to without cable data and cleaning cartridge data and cleaning cartridge data and cleaning cartridge<br />

2 tape incl. description (Ger/US) 1.6 * 5.25", anthracite bezel 1.6 * 5.25", anthracite bezel 1.6 * 5.25", anthracite bezel<br />

drives data and cleaning cartridge max. 1x per system max. 1x per system max. 1x per system<br />

1.6 * 5.25", anthracite bezel<br />

max. 1x per system<br />

S26361-F3128-E101<br />

internal SCSI-Cable For the 2nd tape drive<br />

for connetion of<br />

internal Tape devices<br />

max. 1x per system<br />

S26361-F2848-E3 S26361-F2849-E3 S26361-F3224-E3 S26361-F3157-E3<br />

Tape drive DDS Gen5 Tape drive VXA-2 Tape drive VXA-320 Tape drive LTO2HH Ultrium<br />

S26361-F2848-E31 (only for OBDR) 80GB, 6MB/s, U2W SCSI 160GB, 12MB/s, U160 SCSI 200GB, 24MB/s, U160 SCSI<br />

DDS-G5 for One buttom dis. recov. Connector: HD68 Connector: HD68 Connector: HD68<br />

1x 36GB, 3MB/s, U2W SCSI without cable without cable without cable<br />

Connector: HD68 incl. description (Ger/US) incl. description (Ger/US) incl. description (Ger/US)<br />

without cable data and cleaning cartridge data and cleaning cartridge data and cleaning cartridge<br />

incl. description (Ger/US) 1.6 * 5.25", anthracite bezel 1.6 * 5.25", anthracite bezel 1.6 * 5.25", anthracite bezel<br />

data and cleaning cartridge max. 1x per system max. 1x per system max. 1x per system<br />

1.6 * 5.25", anthracite bezel<br />

max. 1x per system<br />

E<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 10 of 16


System configurator and order-information guide<br />

E <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130<br />

Hard disk 73GB Hard disk 146GB Hard disk 300GB<br />

10000rpm,


S y s t e m c o n f i g u r a t o r a n d o r d e r - i n f o r m a t i o n g u i d e<br />

F <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section V SCSI / RAID Controller<br />

A. on-board SCSI-/ RAID-Controller for accessible drives and SCSI HDD´s<br />

The system is equipped with a two channel Utra 320 onboard SCSI controller<br />

including a full featured RAID Controller with 256MB Cache (suporting the RAID level 0, 1, 5, 10, 50).<br />

As option the onboard RAID Controller can be equipped with a Battery Backup Unit.<br />

This onboard SCSI/RAID controller can be used for the connection of internal tapes and disks drives.<br />

Also one channel can be used for the connection of external Tape devices in the SX10 subsystem.<br />

The following rules apply for the cabling:<br />

The cables for the connection of the onboard RAID controller to the disks in the system are includes in the base unit.<br />

If an internal tape is configured, an additional SCSI cable is needed. (see section "V Hard disk drives / Tapes" )<br />

For the connection of external Tape devices to the on board SCSI controller, also an additional cable is needed in the system.<br />

(plus cable to connect to the subsystem SX10, see configurator SX10)<br />

S26361-F3128-E20<br />

ROM Battery Backup Unit<br />

for on board RAID controller<br />

max. 1x per system<br />

S26361-F3128-E102<br />

external<br />

SCSI-connection<br />

plug:<br />

1x VHDCI / UHD68(S)<br />

max. 1x per system<br />

B. SCSI - controller for internal and external devices.<br />

S26361-F2399-E1<br />

1-channel SCSI U160 Controller<br />

Adaptec 29160<br />

plug:<br />

internal: HD 50-pin & HD68<br />

max. 2x external: HD68<br />

without<br />

cable<br />

64/66 PCI<br />

3.3V and 5V tolerant signaling<br />

max. 2x per system<br />

C. RAID-Controller for external Disk Arrays<br />

S26361-F3006-E128<br />

2-channel RAID Controller U320<br />

LSI<br />

320-2<br />

128MB SDRAM ECC Cache The RAID controller can be used only for<br />

max. 2x default with TBBU the connection of external subsystems (SX30)<br />

plug: internal 2x HD68; Cables for the connection from the RAID Controllers<br />

external: 2x VHDCI to the subsystem see configurator SX30.<br />

without<br />

cable<br />

64/66 PCI controller, 180mm<br />

3.3V and 5V tolerant signaling<br />

max. 2x per system<br />

G<br />

F u j i t s u S i e m e n s C o m p u t e r s<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 1 2 o f 1 6


System configurator and order-information guide<br />

G <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section VI Fibre channel controller<br />

Qlogic controller Emulex Controller<br />

No mix and match for Qlogic and<br />

S26361-F3097-E1 Emulex Fibre channel controllers<br />

2GBit/s FC Controller possible<br />

Qlogic<br />

QLA2340, full height bracket<br />

1 channel 2GBit/sec FC Controller<br />

LC Interface for 50µm Fiber<br />

PCI-X 64Bit / 133MHz, 170mm<br />

3.3V / 5V tolerant signaling<br />

Qlogic controller max. 3x per system<br />

max. 3x or<br />

Emulex<br />

controller<br />

max.<br />

4x<br />

S26361-F3141-E1 S26361-F3306-E1 S26361-F3306-E2<br />

2GBit/s FC Controller 4GBit/s FC Controller 4GBit/s FC Controller<br />

Emulex Emulex Emulex<br />

LP1050Ex, full height bracket LPe1150, full height bracket LPe11002, full height bracket<br />

1 channel 2GBit/sec FC Controller 1 channel 4GBit/sec FC Controller 2 channel 4GBit/sec FC Controller<br />

LC Interface for 50µm Fiber LC Interface for 50µm Fiber LC Interface for 50µm Fiber<br />

PCIe x4, 111,2 x 167,7 mm² PCIe x4, 170mm PCIe x4, 170mm<br />

max. 4x per system max. 4x per system max. 4x per system<br />

All controllers for the connection of external storage systems are delivered without cables.<br />

For the configuration of external cabling see the configurator for external storage systems.<br />

For Fibre Channel SAN also other componets like switches, SFPs and optical wires are<br />

orderable (for details see price liste)<br />

H<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 13 of 16


System configurator and order-information guide<br />

H <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section VII Communication / Network<br />

on-board LAN Controller<br />

Dual Gbit Ethernet Contr. on-board Teaming: Failover, Load Balancing<br />

BroadCom BCM5704 The Intel LAN Controllers Pro 1000MT, 1000MF, 1000MT Dual Port Server<br />

can be used with the on-board controller in Teaming Mode<br />

ext: 2 x RJ 45 connector With Broadcom on-board adapters for Gigabit Ethernet must be used<br />

for the teaming the Broadcom driver.<br />

Two onboard LAN ports can likewise educate a team.<br />

A) Single Port LAN Adapter<br />

S26361-F3054-E1<br />

S26361-F3053-E1<br />

Gigabit Ethernet Contr. 1000SX Gigabit Ethernet Controller 1000TX<br />

Eth. Ctrl 1x1Gbit PCI-X Pro/1000MF LC Eth Ctrl 1x1Gbit PCI-X Pro/1000MT Cu<br />

Intel PRO/1000 MF Server Adapter Intel PRO/1000 MT Server Adapter<br />

PCI-X (PCI64/133), min 165 mm PCI-X (PCI64/133)<br />

ext:LC-connector ext: for RJ45-connector, Cat 5<br />

max. 3x per system max. 3x per system<br />

3x<br />

B) Dual Port LAN Adapter<br />

S26361-F3011-E1<br />

Gigabit Ethernet Controller Dual 1000TX<br />

Eth Ctrl 2x1Gbit PCI-X PRO/1000MT Cu<br />

Intel Pro/1000MT Dual Port Server Ad.<br />

PCI-X<br />

(PCI64/133)<br />

ext: for RJ45-plug, Cat 5<br />

max. 1x per system<br />

C) Dual Port LAN Adapter PCIe x4<br />

while s t o c k s l a s t<br />

S26361-F3143-E1<br />

S26361-F3228-E1<br />

Gigabit Ethernet Contr. dual 1000TX Gigabit Ethernet Controller Dual 1000TX<br />

Eth. Ctrl 2x1Gbit PCIe PRO/1000P Cu Eth Ctrl 2x1Gbit PCIe PRO/1000PT Cu<br />

Intel Pro/1000P dual Server Adapter Intel Pro/1000PT dual Server Adapter<br />

4x PCIe x4, 170mm PCIe x4<br />

ext: for RJ45-plug, Cat 5 ext: for RJ45-plug, Cat 5<br />

connection with Cat 5 cabling max. 2x per system<br />

SW: VLAN, Fast & Gbit Etherchannel<br />

max. 4x per system<br />

I<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 14 of 16


System configurator and order-information guide<br />

I <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Section VIII System Management Products (RemoteView)<br />

S26361-F1790-E221<br />

S26361-F2425-E103<br />

RemoteView Software V5.0<br />

RSB S2 LP 3HU<br />

Installation and configuration of RemoteView Service Board S2<br />

RemoteView Web and LAN FrontEnd Low Profile Version with 3 U bracket<br />

RSB, BMC-Manager, RTDS, FreeDOS for one standard PCI-slot<br />

and online manuals incl. cables and RV SW<br />

max. 1x per system<br />

S26361-F2425-E305<br />

RSB S2 LP external power supply<br />

RemoteView Service Board S2<br />

low profile external power supply<br />

including power cable<br />

with Euro- and Euro socket connector<br />

Section IX Miscellaneous<br />

option for floorstand<br />

keyboards for floorstand versions for following countries: USB Keyboard: S26381-K340-E120<br />

S26381-K397-E110 USA / international KBPC PX D, professional keyboard<br />

S26381-K397-E120<br />

Germany<br />

S26381-K397-E140<br />

France<br />

S26381-K397-E155 Sweden / Finland<br />

S26381-K397-E165 United Kingdom<br />

S26381-K397-E180<br />

Spain<br />

S26381-K397-E185<br />

Italy<br />

Section X Power Cords<br />

The Floorstand version contains two power cords with German "Schuko" (CEE 7/7) connector<br />

as standard (S26361-F3151-L100).<br />

For shipments in other countrys, two of the following cables have to be ordered seperatly.<br />

16A CEE connector (IEC309, blue) 3.5 m 2x S26361-F3151-E200<br />

16A IEC320 C19 -> BS13/13 3.5 m 2x S26361-F3151-E400<br />

16A IEC320 C19 -> US NEMA L6-20 4.0 m 2x S26361-F3151-E500<br />

The Rack version contains two power cords with IEC320 C14 connnector (S26361-F3151-L350)<br />

With this cabel the system can be connected to UPS or power socket outlets with C14 connector.<br />

Attention:<br />

This power cord can be used only in 200-240V enironment<br />

due to the limitation of the C14 connector to 10A.<br />

In 110V eniroment, one of the following power cords must be used:<br />

For directly connection to a power socket outlet 3.5 m 2x S26361-F3151-E300<br />

or a UPS with 16A outlet (IEC320 C19)<br />

To connect the system outside of the rack in USA 4.0 m 2x S26361-F3151-E500<br />

In 200-240V enironment the following cables can be used as alternative:<br />

16A IEC320 C19 -> Schuko (CEE 7/7) 2.5 m 2x S26361-F3151-E100<br />

16A CEE connector (IEC309, blue) 3.5 m 2x S26361-F3151-E200<br />

16A IEC320 C19 -> BS13/13 3.5 m 2x S26361-F3151-E400<br />

16A IEC320 C19 -> US NEMA L6-20 4.0 m 2x S26361-F3151-E500<br />

Overview about all available power cords with 16A connnector:<br />

1x Power cord 16A IEC320 C19 -> Schuko (CEE 7/7) 2.5 m S26361-F3151-E100<br />

1x Power cord 16A IEC320 C19 -> 16A CEE (IEC309, blue) 3.5 m S26361-F3151-E200<br />

1x Power cord 16A IEC320 C19 -> 16A IEC320 C20 3.5 m S26361-F3151-E300<br />

1x Power cord 16A IEC320 C19 -> 10A IEC320 C14 2.5 m S26361-F3151-L350<br />

1x Power cord 16A IEC320 C19 -> BS13/13 3.5 m S26361-F3151-E400<br />

1x Power cord 16A IEC320 C19 -> US NEMA L6-20 4.0 m S26361-F3151-E500<br />

End <strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong><br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 15 of 16


System configurator and order-information guide<br />

<strong>PRIMERGY</strong> <strong>TX600</strong> <strong>S3</strong> Status 24.04.2006<br />

Cange Report<br />

Date Order number Changes<br />

2006-02-13 first draft<br />

Fujitsu Siemens Computers<br />

Enterprise Products - <strong>PRIMERGY</strong> Server 16 of 16