System Configurator <strong>and</strong> Ordering Information Guide<br />

May 2008<br />

Contents<br />

Configuration Scheme for Online <strong>UPSs</strong> <strong>and</strong> Battery Extensions<br />

<strong>Masterguard</strong> <strong>UPSs</strong> for PRIMEPOWER / PRIMERGY Servers<br />

Change History<br />

PRIMEPOWER Servers


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

Configuration <strong>and</strong> orderable options for<br />

uninterruptible online (VFI) power supplies (<strong>UPSs</strong>)<br />

<strong>from</strong> <strong>Masterguard</strong> (MGUA)<br />

- Uninterruptible online power supplies (<strong>UPSs</strong>) as tower devices with 1000, 3000, 10000 <strong>and</strong> 20000 VA<br />

- Uninterruptible online power supplies (<strong>UPSs</strong>) as rack devices with 1000, 3000, 6000 <strong>and</strong> 10000 VA<br />

- <strong>and</strong> external battery extensions to increase the runtimes<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 2 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

A <strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

Uninterruptible power supply for 230 V / 400 V<br />

If a UPS (uninterruptible power supply) is installed,<br />

a rack installation kit (only 3 kVA <strong>UPSs</strong>) <strong>and</strong><br />

a bracket for each UPS / battery must be ordered.<br />

If a UPS / battery is configured with the SystemArchitekt,<br />

these necessary accessories for the PRIMECENTER<br />

rack are automatically inserted in the order list.<br />

In the case of <strong>UPSs</strong>, a network management interface,<br />

i.e. the LAN adapter (D:UPS-LAN2), should always be ordered, too.<br />

If the network management interface is used, the number<br />

of nodes / servers per UPS can be exp<strong>and</strong>ed easily.<br />

For signaling via LAN, the UPS only requires one LAN connection.<br />

However, the maximum power per UPS must be heeded.<br />

A V.24 (serial) signal can be used instead of the network management card.<br />

Only 1 server can be connected serially. However, it is possible to control<br />

further servers per shutdown client via its MopUPS installation.<br />

Information on configuration <strong>and</strong> on calculation of the<br />

UPS power can be found in this configurator.<br />

N.B.: not suited for a 110V power supply!<br />

Supplied software CD<br />

Every UPS comes with a software package that permits direct management connection of up to 3 servers under operating systems such as<br />

WINDOWS, LINUX <strong>and</strong> SOLARIS. In addition, the package contains the high availability software, which must be licensed <strong>and</strong> enables<br />

applications such as server clustering, clustering of parallel UPS systems <strong>and</strong> UPS fleet management. High availability software always requires<br />

a LAN controller in the UPS. Created configurations can be adapted variably to productive operation with subsequent licensing (which is then<br />

chargeable).<br />

B<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 3 of 12


B<br />

<strong>Tower</strong> online UPS variants<br />

System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

These MGUA <strong>UPSs</strong> are true double conversion online <strong>UPSs</strong>, classified<br />

as VFI 111 <strong>UPSs</strong> (voltage <strong>and</strong> frequency independent)<br />

A CD with management software <strong>and</strong> basic license [*] for 3 servers (3-1-1-25)<br />

comes with the UPS. The runtime can be increased with up to 2 external battery<br />

extensions. Automatic <strong>and</strong> manual bypass, firmware can be flashed, fusing of the<br />

output power circuits, etc.<br />

[*] You can find explanations on the<br />

licenses on the Software page<br />

D:UPS-T1-PV1 D:UPS-T3-PV1 D:UPS31-T10-PV1 D:UPS31-T20-PV1<br />

MGUA online UPS 1KVA MGUA online UPS 3KVA MGUA online UPS 10KVA MGUA online UPS 20KVA<br />

<strong>Tower</strong> modell incl. battery <strong>Tower</strong> modell incl. battery <strong>Tower</strong> modell incl. battery <strong>Tower</strong> modell incl. battery<br />

Active power 700 W Active power 2100 W Active power 7000 W Active power 14000 W<br />

Color: ergo gray Color: ergo gray Color: ergo gray; can be rolled Color: ergo gray; can be rolled<br />

Runtime: 7 min Runtime: 6 min Runtime: 5 min Runtime: 10 min<br />

Management: RS232/V.24 Management: RS232/V.24 Management: RS232/V.24 Management: RS232/V.24<br />

Connector: COM SubD-9 Connector: COM SubD-9 Connector: COM SubD-9 Connector: COM SubD-9<br />

1x slot for alternative adapter 1x slot for alternative adapter 1x slot for alternative adapter 1x slot for alternative adapter<br />

1x V24 cable (data cable) 1x V24 cable (data cable) 1x V24 cable (data cable) 1x V24 cable (data cable)<br />

CD with management software CD with management software CD with management software CD with management software<br />

<strong>and</strong> basic license for 3 servers <strong>and</strong> basic license for 3 servers <strong>and</strong> basic license for 3 servers <strong>and</strong> basic license for 3 servers<br />

Output side, 1-phase Output side, 1-phase Output side, 1-phase Output side, 1-phase<br />

4x IEC320 C13 (10A)<br />

2x IEC320 C19 (16A)<br />

1x permanent connection<br />

1x permanent connection<br />

Distributor supplied: Distributor supplied: No distributor supplied: No distributor supplied:<br />

1x IEC320 C13 on 3x safety plug 1x IEC320 C19 on 3x safety plug<br />

Mains cable with safety plug Mains cable with safety plug 3-phase permanent connection 3-phase permanent connection<br />

(CEE 7/7) plug; 1.8m (CEE 7/7) plug; 1.8m required by electrician required by electrician<br />

36-month warranty: 12 months 36-month warranty: 12 months 36-month warranty [1]: 12 months 36-month warranty [1]: 12 months<br />

on-site, 24 months bring-in on-site, 24 months bring-in on-site, 24 months bring-in on-site, 24 months bring-in<br />

service by FSC PRS [2] service by FSC PRS [2] service by <strong>Masterguard</strong> service by <strong>Masterguard</strong><br />

D:UPS31-T10PA1<br />

External UPS battery pack (BP)<br />

for 10 kVA tower UPS<br />

Color: ergo gray; rollable<br />

incl. UPS connection cable,<br />

D:UPS31-T20PA1<br />

External UPS battery pack (BP)<br />

for 20 kVA tower UPS<br />

Color: ergo gray; rollable<br />

incl. UPS connection cable,<br />

max. 2 ext. batteries / <strong>UPSs</strong><br />

max. 2 ext. batteries / <strong>UPSs</strong><br />

Max. 2 24-month warranty [1]: 24-month warranty [1]:<br />

per UPS 12 mth. on-site / 12 mth. bring-in 12 mth. on-site / 12 mth. bring-in<br />

service by <strong>Masterguard</strong><br />

service by <strong>Masterguard</strong><br />

Runtime:<br />

Runtime:<br />

1 ext. battery: 23 min (full load) 1 ext. battery: 41 min (full load)<br />

2 ext. battery: 43 min (full load) 2 ext. battery: 81 min (full load)<br />

Max. 2x per UPS<br />

Max. 2x per UPS<br />

[1] Conclusion of a 3-year service<br />

agreement is strongly advised.<br />

You can find service offerings under Service<br />

[2] Top-up services can be<br />

obtained <strong>from</strong> FSC PRS<br />

C<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 4 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

C <strong>Rack</strong> online UPS variants [1] Conclusion of a 3-year service<br />

agreement is strongly advised.<br />

These MGUA <strong>UPSs</strong> are true double conversion online <strong>UPSs</strong>, classified<br />

as VFI 111 <strong>UPSs</strong> (voltage <strong>and</strong> frequency independent)<br />

A CD with management software <strong>and</strong> basic license [*] for 3 servers (3-1-1-25)<br />

comes with the UPS. The runtime can be increased with up to 2 to 5 external battery.<br />

extensions. Automatic <strong>and</strong> manual bypass, firmware can be flashed, fusing of the<br />

output power circuits, etc.<br />

You can find service offerings under Service<br />

[2] Top-up services can be<br />

obtained <strong>from</strong> FSC PRS<br />

[*] You can find explanations on the<br />

licenses on the Software page<br />

Battery packs are mounted directly<br />

beneath the UPS in a <strong>Rack</strong><br />

D:UPS-R1-PV1 D:UPS-R3-PV1 D:UPS-R6-PV1 D:UPS-R10-PV1<br />

MGUA online UPS 1KVA MGUA -Online USV 3KVA MGUA -Online USV 6KVA MGUA -Online USV 10KVA<br />

<strong>Rack</strong> model incl. battery <strong>Rack</strong> model without battery <strong>Rack</strong> model without battery <strong>Rack</strong> model without battery<br />

Active power 700 W Active power 2100 W Active power 4200 W Active power 7000 W<br />

Color: anthracite Color: anthracite Color: anthracite Color: anthracite<br />

Runtime: 7 min Runtime: 0 min Runtime: 0 min Runtime: 0 min<br />

Management: RS232/V.24 Management: RS232/V.24 Management: RS232/V.24 Management: RS232/V.24<br />

Connector: COM SubD-9 Connector: COM SubD-9 Connector: COM SubD-9 Connector: COM SubD-9<br />

1x slot for alternative adapter 1x slot for alternative adapter 1x slot for alternative adapter 1x slot for alternative adapter<br />

1x V24 cable (data cable) 1x V24 cable (data cable) 1x V24 cable (data cable) 1x V24 cable (data cable)<br />

CD with management software CD with management software CD with management software CD with management software<br />

<strong>and</strong> basic license for 3 servers <strong>and</strong> basic license for 3 servers <strong>and</strong> basic license for 3 servers <strong>and</strong> basic license for 3 servers<br />

Output side, 1-phase Output side, 1-phase Output side, 1-phase Output side, 1-phase<br />

4x IEC320 C13 (10A) 1x IEC320 C19 (16A) 2x IEC320 C19 (16A) 2x IEC320 C19 (16A)<br />

1x permanent connection<br />

1x permanent connection<br />

Distributor supplied: Distributor supplied: Distributor / cable supplied: No distributor supplied:<br />

1x IEC320 C13 on 3x safety plug 1x IEC320 C19 on 3x safety plug 1x CEE cable 32A (0.5m)<br />

Mains cable with safety plug Mains cable with safety plug 1-phase permanent connection 1-phase permanent connection<br />

(CEE 7/7) plug; 1.8m (CEE 7/7) plug; 1.8m required by electrician, additionally required by electrician<br />

36-month warranty: 12 months 36-month warranty: 12 months cable 5m with IEC309 (CEE) plug 36-month warranty [1]: 12 months<br />

on-site, 24 months bring-in on-site, 24 months bring-in for connection to permanet input on-site, 24 months bring-in<br />

service by FSC PRS [2] service by FSC PRS [2] 36-month warranty [1]: 12 months service by <strong>Masterguard</strong><br />

Occupies 2U in the rack Occupies 2U in the rack on-site, 24 months bring-in Occupies 3U in the rack<br />

service by <strong>Masterguard</strong><br />

Incl. rack installation kit<br />

D:GPRAC-ZB5211<br />

Occupies 3U in the rack<br />

Bracket up to 50 kg<br />

Incl. rack installation kit<br />

D:90712-16AC<br />

D:GPRAC-ZB5211 Power cable D:GPRAC-ZB5215 D:GPRAC-ZB5215<br />

Bracket up to 50 kg IEC309 (CEE) blue, 16A Bracket 150 kg Bracket 150 kg<br />

D:GPRAC-ZBMG061<br />

<strong>Rack</strong> installation kit for MGUA <strong>UPSs</strong> up to 3kVA<br />

for mounting a UPS in a P/D/3rd-party rack<br />

D:UPS-R6R10-PA1<br />

UPS battery pack (BP) for 6 / 10 kVA rack UPS<br />

For MGUA online <strong>UPSs</strong> <strong>and</strong> runtime extensions<br />

Color: anthracite incl. UPS connection cable,<br />

Required 1x per UPS / extension Max. 3 ext. batteries 6kVA <strong>UPSs</strong> Max. 4 ext. batteries/10kVA <strong>UPSs</strong><br />

Runtime:<br />

Runtime:<br />

Max 2-5 1x ext. battery: 12 min (full load) 1x ext. battery: 5 min (full load)<br />

per UPS D:UPS-R1-PA1 D:UPS-R2R3-PA1 2x ext. battery: 29 min (full load) 2x ext. battery: 16 min (full load)<br />

UPS battery pack (BP) for UPS battery pack (BP) for 3x ext. battery: 45 min (full load) 3x ext. battery: 26 min (full load)<br />

1 kVA rack UPS 3 kVA rack UPS 4x ext. battery: 34 min (full load)<br />

Color: anthracite Color: anthracite Max. 3x per 6 kVA UPS Max. 4x per 10kVA UPS<br />

incl. UPS connection cable, incl. UPS connection cable, Occupies 3U in the rack<br />

Max 2 ext. batteries / <strong>UPSs</strong> Max 5 ext. batteries / <strong>UPSs</strong> Incl. rack installation kit<br />

Runtime:<br />

Runtime:<br />

1x ext. battery: 27 min (full load) 1x ext. battery: 5 min (full load) D:GPRAC-ZB5215<br />

2x ext. battery: 51 min (full load) 2x ext. battery: 16 min (full load) Bracket 150 kg<br />

Max. 2x per UPS<br />

3x ext. battery: 23 min (full load)<br />

Occupies 2U in the rack<br />

4x ext. battery: 34 min (full load)<br />

5x ext. battery: 43 min (full load)<br />

D:UPS-R10-RACKVKAB<br />

D:GPRAC-ZB5211 Max 5x per UPS UPS cable, 3.5m, between BP + rack 6kVA-10kVA<br />

Bracket up to 50 kg Occupies 2U in the rack to extend the battery connection cable<br />

if the distance between the control unit <strong>and</strong> ext.<br />

D:GPRAC-ZB5211<br />

battery extension is too great, for example ext. battery<br />

Bracket up to 50 kg<br />

extension in the neighboring rack.<br />

Max. 1x per ext. battery extension<br />

D:GPRAC-ZBMG061<br />

<strong>Rack</strong> installation kit for MGUA <strong>UPSs</strong> up to 3kVA<br />

for mounting a UPS in a P/D/3rd-party rack<br />

For MGUA online <strong>UPSs</strong> <strong>and</strong> runtime extensions<br />

Required 1x per UPS / extension<br />

D<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 5 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

D<br />

Accessories LAN/V.24 serial<br />

All accessory components for the MGUA online <strong>UPSs</strong><br />

can be used for both tower <strong>and</strong> rack models.<br />

In conjunction with a PC rack order ex works, the<br />

ordered accessories are installed. In all other cases,<br />

the components are not installed ex works.<br />

LAN<br />

EOL 03/08 as soon as available (03/08)<br />

V.24 / serial<br />

D:UPS-LAN2 D:UPS-LAN3 UPS signal cabel V.24, length 5m<br />

USV LAN controller USV LAN controller For RS232/V.24 interface on the server<br />

SNMP, WEB management SNMP, WEB management (interface: SER or COM, 9-pin D-SUB);<br />

10 Mbit only for MGUA <strong>UPSs</strong> 10/100 Mbit only for MGUA <strong>UPSs</strong> This cable comes with every MGUA UPS.<br />

<strong>from</strong> this configurator (RoHS-<br />

<strong>from</strong> this configurator (RoHScompatible,<br />

D:UPS*) can be used compatible, D:UPS*) can be used D:UPS-V24-RJ45KAB<br />

Software supplied with the UPS Software supplied with the UPS Adapter cable D-SUB9 on RJ45<br />

without LAN connection cable without LAN connection cable Is required for PRIMEPOWER<br />

Occupies optional adapter slot Occupies optional adapter slot 250 / 450 with RJ45 serial port<br />

Max. 1x per UPS Max. 1x per UPS Cable length 3,5m<br />

Must be ordered additionally!<br />

D:GP7KB-1310<br />

UTP CAT5 LAN cable<br />

Length: 10m, RJ45 plug<br />

D:GP7KB-1305<br />

UTP CAT5 LAN cable<br />

Length: 5m, RJ45 plug<br />

All <strong>UPSs</strong> are supplied with the signaling cable <strong>and</strong> the<br />

serial (V.24) interface. A server can thus be connected.<br />

The LAN adapter must be used to connect 2 or more servers.<br />

If a LAN adapter is built in, a V.24 connection is no longer possible<br />

E<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 6 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

E<br />

PDU1<br />

For better serviceability PDU 1 <strong>and</strong> PDU2 offers a Bypass switch to disconnect UPS<br />

<strong>from</strong> mains <strong>and</strong> all load will be connected to mains directly. This allows to run load<br />

while UPS is maintained.<br />

D:UPS-PDU1<br />

UPS PDU1 3xC32A-2xC16A-2xIEC16A<br />

to extend the sockets of a 6kVA or 10kVA rack UPS<br />

Is connected to the 1-phase permanent connection<br />

of the UPS by an electrician.<br />

Output side, 1-phase<br />

3x IEC309 CEE blue (32A)<br />

2x IEC309 CEE blue (16A)<br />

3x IEC320 C19 (16A)<br />

Occupies 4U in the rack<br />

Max. 1x per 6 kVA rack UPS (D:UPS-R6-PV1)<br />

Max. 1x per 10 kVA rack UPS (D:UPS-R10-PV1)<br />

PDU2<br />

D:UPS-PDU2<br />

UPS PDU1 3xC32A-2xC16A-2xIEC16A<br />

to extend the sockets of a 6kVA or 10kVA rack UPS<br />

<strong>and</strong> parallel connection of two 6kVA or 10kVA rack <strong>UPSs</strong><br />

Is connected to the 1-phase permanent connection<br />

of both <strong>UPSs</strong> by an electrician.<br />

Output side, 1-phase<br />

3x IEC309 CEE blue (32A)<br />

2x IEC309 CEE blue (16A)<br />

3x IEC320 C19 (16A)<br />

Occupies 4U in the rack<br />

Max. 1x per 6 kVA rack UPS (D:UPS-R6-PV1)<br />

Max. 1x per two 10 kVA rack <strong>UPSs</strong> (D:UPS-R10-PV1)<br />

Operation only permitted with two connected <strong>UPSs</strong><br />

PDU 1 <strong>and</strong> 2 front view<br />

PDU 1 is mounted directly above the UPS in a <strong>Rack</strong><br />

Preassembled, 3-wire cable for permanent connection of<br />

PDU 1 <strong>and</strong> 2 is already conneccted at the PDU side.<br />

2 cables for PDU 1 <strong>and</strong> 4 for PDU2<br />

Extension of the UPS power to 12kVA / 20kVA by<br />

parallel connection of two 6kVA or 10kVA <strong>UPSs</strong><br />

LAN adapter always required for each UPS<br />

License cluster software (D:UPSSW-HA-CLUSTER)<br />

License enterprise software (D:UPSSW-HA-ENTERPR)<br />

is also required<br />

PDU 2 is mounted always between both <strong>UPSs</strong> in a <strong>Rack</strong><br />

whereas at the second arangement the Battery Pack<br />

is mounted above the UPS in a <strong>Rack</strong>. Refer to the drawings<br />

Additionally without service bypass<br />

a 50 A PDU is also available.<br />

Note: cannot be ordered together with<br />

a PRIMEPOWER PRIMECENTER <strong>Rack</strong><br />

Can be used only for:<br />

6kVA <strong>Rack</strong> D:UPS-R6-PV1<br />

10kVA <strong>Rack</strong> D:UPS-R10-PV1<br />

10kVA <strong>Tower</strong> D:UPS31-T10-PV1<br />

S26361-F2262-E500<br />

UPS PDU 50A 2U,6x16A+4x10A IEC320<br />

Power distribution unit for UPS hard wire output<br />

For APC Online UPS <strong>and</strong> Runtime expansion modules<br />

occupies 2U in racks<br />

S26361-F2262-L500<br />

UPS PDU 50A 2U,6x16A+4x10A IEC320<br />

Loose delivery<br />

Conection at customer side has to<br />

be done by an electrician.<br />

D:GPRAC-ZB31<br />

Dummy Panel for 19inch rack, 2U<br />

D:GPRAC-ZB5212<br />

Bracket up to 100 kg<br />

F<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 7 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

F<br />

Management software<br />

Supplied software CD<br />

Every UPS comes with a software package that permits direct management connection of up to 3 servers under operating systems such as<br />

WINDOWS, LINUX <strong>and</strong> SOLARIS. In addition, the package contains the high availability software, which must be licensed <strong>and</strong> enables<br />

applications such as server clustering, clustering of parallel UPS systems <strong>and</strong> UPS fleet management. High availability software always requires<br />

a LAN controller in the UPS. Created configurations can be adapted variably to productive operation with subsequent licensing (which is then<br />

chargeable).<br />

D:UPSSW-BASIS<br />

UPS management software MGUA BASIS 3-1-1-25<br />

This license is supplied with the UPS.<br />

Only order this item if additional servers<br />

are to be connected.<br />

All the software is supplied on CD with the UPS.<br />

However, only the part specified in the license can be<br />

used (on-dem<strong>and</strong> model). Other parts/functions can be<br />

enabled by license keys (subject to a fee).<br />

D:UPSSW-HA-CLUSTER<br />

UPS mgt. SW option CLUSTER 2-3-5-50<br />

D:UPSSW-HA-ENTERPR<br />

UPS mgt. SW option ENTERPRISE 25-3-5-50<br />

D:UPSSW-SRVGRID<br />

UPS mgt. SW option SERVER GRID 25-1-1-50<br />

Explanation of the software license coding:<br />

[3]-1-1-25 means the software can be installed<br />

on three servers.<br />

It is able to manage a UPS cluster (3-[1]-1-25)<br />

here with one UPS (3-1-[1]-25).<br />

With the license, 25 clients (3-1-1-[25]) per UPS<br />

can be powered off via shutdown (IP shutdown).<br />

The shutdown client is the MopUPS NSA client;<br />

all others are subject to a charge.<br />

Management software order<br />

numbers<br />

D:UPSSW-BASIS<br />

License coding<br />

3-1-1-25<br />

Explanation of the licenses<br />

This license comes with the UPS. Up to three servers can be connected to a UPS<br />

(these servers do not work in a cluster) <strong>and</strong> are notified individually by the UPS if<br />

there is imminent danger of a power failure. The software can manage a UPS. The<br />

three servers can notify a total of up to 25 clients via LAN of the impending power<br />

failure <strong>and</strong> initiate shutdown. If a server fails or the client cannot be reached, the<br />

client learns nothing about the power failure.<br />

D:UPSSW-HA-CLUSTER<br />

2-3-5-50<br />

This package can be ordered optionally <strong>and</strong> addresses a dual-node cluster<br />

application. The number of cluster nodes can be increased by adding further<br />

licenses in grids of 2 (a quad-node cluster requires 2 licenses). The license can<br />

manage up to 3 groups, each with up to 5 UPS systems. The package is aimed at<br />

distributed cluster applications in which a pool of parallel <strong>UPSs</strong> with up to 5 <strong>UPSs</strong><br />

each is intended for servers, infrastructure (data transport) <strong>and</strong> consolidated storage<br />

hardware. The servers involved can address a total of 50 clients.<br />

D:UPSSW-HA-ENTERPR<br />

25-3-5-50<br />

This package can be ordered optionally <strong>and</strong> is designed for power solutions with a<br />

powerful server that can be split into virtual machines (example: PRIMEPOWER).<br />

Configurations such as in the cluster version can be created for the distributed<br />

environment used by the virtual server.<br />

D:UPSSW-SRVGRID<br />

25-1-1-50<br />

This package can be ordered optionally <strong>and</strong> addresses completely fitted blade<br />

servers. The power quality information must be passed to many systems that are<br />

accommodated in a chassis <strong>and</strong> supplied by a UPS. The <strong>UPSs</strong> can be managed<br />

<strong>from</strong> any desired server of the blade, with the result that there is also power<br />

management when individual blades are inactive or have failed.<br />

G<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 8 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

G<br />

Services offered for tower <strong>UPSs</strong><br />

In addition to the 36-month warranty (12 months on-site, 24 months bring-in) for all tower <strong>and</strong> rack <strong>UPSs</strong>, there are<br />

further offerings for selected <strong>UPSs</strong> / batttery types that can be ordered extra.<br />

They can only be ordered together with the UPS / battery extension, i.e. not subsequently.<br />

The customer receives a 3-year certificate for services. The service provider named on it must be informed of the<br />

existence of this service certificate.<br />

D:UPS31-T20-PV1<br />

MGUA online UPS 20KVA<br />

D:UPS31-T10-PV1<br />

MGUA online UPS 10KVA<br />

D:9072-IBS-D<br />

Commissioning within<br />

Germany<br />

D:9071-IBS-D<br />

Commissioning within<br />

Germany<br />

D:9072-IBS-EU<br />

Commissioning within<br />

Europe<br />

D:9071-IBS-EU<br />

Commissioning within<br />

Europe<br />

D:9072-P203-SBAS<br />

D:9072-P103-SBAS<br />

SERVICE BASIC<br />

SERVICE BASIC<br />

Lifecycle: months 00-36 Lifecycle: months 00-36<br />

Covers:<br />

Covers:<br />

- 36-month replacement service - 36-month replacement service<br />

- Fault report h<strong>and</strong>ling/rectification - Fault report h<strong>and</strong>ling/rectification<br />

- Spare part on site in 24h (D)/48h (EU) - Spare part on site in 24h (D)/48h (EU)<br />

Does not cover:<br />

Does not cover:<br />

- Setup/dismantling, transport prep. - Setup/dismantling, transport prep.<br />

D:9072-P203-SERW<br />

D:9072-P103-SERW<br />

SERVICE extension<br />

SERVICE extension<br />

UPS life cycle: months 37+ UPS life cycle: months 37+<br />

Covers: 36 months<br />

Covers: 36 months<br />

Content: as basic package, + Content: as basic package, +<br />

battery replacement in 4th year<br />

battery replacement in 4th year<br />

D:UPS31-T20PA1<br />

D:UPS31-T10PA1<br />

UPS battery pack (BP) for<br />

UPS battery pack (BP) for<br />

20 kVA tower UPS 10 kVA tower UPS<br />

D:9072-A203-SBAS<br />

D:9072-A103-SBAS<br />

SERVICE BASIC<br />

SERVICE BASIC<br />

Lifecycle: months 00-36 Lifecycle: months 00-36<br />

Covers:<br />

Covers:<br />

- 36-month replacement service - 36-month replacement service<br />

- Fault report h<strong>and</strong>ling/rectification - Fault report h<strong>and</strong>ling/rectification<br />

- Spare part on site in 24h (D)/48h (EU) - Spare part on site in 24h (D)/48h (EU)<br />

Does not cover:<br />

Does not cover:<br />

- Setup/dismantling, transport prep. - Setup/dismantling, transport prep.<br />

D:9072-A203-SERW<br />

D:9072-A103-SERW<br />

SERVICE extension<br />

SERVICE extension<br />

UPS life cycle: months 37+ UPS life cycle: months 37+<br />

Covers: 36 months<br />

Covers: 36 months<br />

Content: as basic package, + Content: as basic package, +<br />

battery replacement in 4th year<br />

battery replacement in 4th year<br />

H<br />

END<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 9 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

H<br />

Services offered for rack <strong>UPSs</strong><br />

In addition to the 36-month warranty (12 months on-site, 24 months bring-in) for all tower <strong>and</strong> rack <strong>UPSs</strong>, there are<br />

further offerings for selected <strong>UPSs</strong> / batttery types that can be ordered extra.<br />

They can only be ordered together with the UPS / battery extension, i.e. not subsequently.<br />

The customer receives a 3-year certificate for services. The service provider named on it must be informed of the<br />

existence of this service certificate.<br />

D:UPS-R6-PV1<br />

MGUA online UPS with 6KVA<br />

D:UPS-R10-PV1<br />

MGUA online UPS with 10KVA<br />

D:9071R-P607-SBAS<br />

SERVICE BASIC<br />

D:S-RU10K-BAS<br />

SERVICE BASIC<br />

Lifecycle: months 00-36 Lifecycle: months 00-36<br />

Covers:<br />

Covers:<br />

- 36-month replacement service - 36-month replacement service<br />

- Removal/installation by customer - Removal/installation by customer<br />

- Transport by manufacturer - Transport by manufacturer<br />

- Agreement with manufacturer - Agreement with manufacturer<br />

- Spare part on site in 24h (D)/48h (EU)<br />

D:9071R-P607-SERW<br />

D:S-RU10K-BAS-E<br />

SERVICE extension<br />

SERVICE extension<br />

UPS life cycle: months 37+ UPS life cycle: months 37+<br />

Covers: 36 months<br />

Covers: 36 months<br />

Content: as basic package<br />

Content: as basic package<br />

D:UPS-R6R10-PA1<br />

D:UPS-R6R10-PA1<br />

UPS battery pack (BP) for<br />

UPS battery pack (BP) for<br />

6 kVA rack UPS 10 kVA rack UPS<br />

D:9071R-A607-SBAS<br />

D:S-RA10K-BAS<br />

SERVICE BASIC<br />

SERVICE BASIC<br />

Lifecycle: months 00-36 Lifecycle: months 00-36<br />

Covers:<br />

Covers:<br />

- 36-month replacement service - 36-month replacement service<br />

- Fault report h<strong>and</strong>ling/rectification - Fault report h<strong>and</strong>ling/rectification<br />

- Spare part on site in 24h (D)/48h (EU) - Spare part on site in 24h (D)/48h (EU)<br />

- Transport by manufacturer - Transport by manufacturer<br />

Does not cover:<br />

Does not cover:<br />

- Setup/dismantling, transport prep. - Setup/dismantling, transport prep.<br />

D:9071R-A607-SERW<br />

D:S-RA10K-BAS-E<br />

SERVICE extension<br />

SERVICE extension<br />

UPS life cycle: months 37+ UPS life cycle: months 37+<br />

Covers: 36 months<br />

Covers: 36 months<br />

Content: as basic package, + Content: as basic package, +<br />

battery replacement in 4th year<br />

battery replacement in 4th year<br />

End<br />

Fujitsu Siemens Computers Enterprise Products - PRIMEPOWER / PRIMERGY Servers 10 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

For information on <strong>Masterguard</strong> <strong>UPSs</strong> in the Internet, refer to:<br />

http://extranet.fujitsu-siemens.com/vil/pc/vil/primergy/components/ds_online-rack-usv-a_e_serie_en.pdf<br />

http://extranet.fujitsu-siemens.com/vil/pc/vil/primergy/components/ds_online-tower-usv-a_e_serie_en.pdf<br />

Fujitsu Siemens Computers Enterprise Products - PRIMERGY Servers 11 of 12


System Configurator <strong>and</strong> Order Information Guide<br />

<strong>Tower</strong> <strong>and</strong> <strong>Rack</strong> <strong>UPSs</strong> <strong>from</strong> <strong>Masterguard</strong> Date of issue 28.04.2008<br />

Change History<br />

Date Part number Change<br />

Nov. 17, 2007 S26361-F2262-E500 New 50A PDU added plus some typo's corrected.<br />

Feb. 22, 2007<br />

Description PDU mounting <strong>and</strong> Hyperlink Datasheet inserted<br />

May 28, 2006<br />

Revision, V.24 cable added<br />

May 15, 2006<br />

First-time creation <strong>and</strong> changeover to RoHS-compatible components<br />

Fujitsu Siemens Computers Enterprise Products - PRIMERGY Servers 12 of 12