S4000<br />

Basic device with time function – SNV 4274SL / SNV 4074ST<br />

Applications<br />

• Monitoring of limit values in the process industry<br />

• Monitoring of emergency stop applications<br />

• Monitoring of <strong>safety</strong> gates<br />

• Monitoring of interlocks<br />

• Monitoring of light barriers<br />

• Up to PL e / Category 4 (EN ISO 13849-1)<br />

• Up to SIL CL 3 (EN 62061)<br />

Features<br />

• Continuously adjustable, analog time setting<br />

• Time ranges 3s, 30s or 300s<br />

• Retriggering of the time delay possible<br />

• Single-channel or two-channel control<br />

• Manual or automatic start<br />

• Cross monitoring<br />

OFF-delay with retriggering function (SNV 4274SL)<br />

After the supply voltage is applied to terminals A1/A2 and the <strong>safety</strong> inputs are<br />

closed, the contacts are switched on immediately, either automatically or by pressing<br />

the reset button (manual start). When the <strong>safety</strong> inputs are opened/de-energized,<br />

the contacts are switched off immediately or with a release delay.<br />

The set release delay only expires if the <strong>safety</strong> inputs are opened longer than the<br />

release delay set on the device. If the <strong>safety</strong> inputs are closed again before the<br />

release delay has expired (retriggering), the delayed contacts will remain closed, too.<br />

ON-delay function (SNV 4074ST)<br />

After the supply voltage is applied to terminals A1/A2 and the <strong>safety</strong> inputs are<br />

closed, the contacts are switched on immediately or with a response delay, either<br />

automatically or by pressing the reset button (manual start). When the <strong>safety</strong><br />

inputs are opened/de-energized the contacts are switched off immediately.<br />

Circuit diagrams<br />

SNV 4274SL<br />

SNV 4074ST<br />

66