07.01.2015 Views

PowerFlex 700 AC Drives

PowerFlex 700 AC Drives

PowerFlex 700 AC Drives

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3-2 Programming and Parameters<br />

➊➋➌➍<br />

File<br />

Group<br />

No.<br />

UTILITY<br />

Drive . . .<br />

Diagnostics<br />

MOTOR . . .<br />

Torq . . .<br />

Parameter Name & Description<br />

198 [Load Frm Usr Set]<br />

Loads a previously saved set of<br />

parameter values from a selected user<br />

set location in drive nonvolatile memory<br />

to active drive memory.<br />

216 [Dig In Status]<br />

Status of the digital inputs.<br />

Values<br />

Default:<br />

Options:<br />

x x x x x x x x x x 0 0 0 0 0 0<br />

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0<br />

Bit #<br />

434 [Torque Ref B Mult]<br />

Default:<br />

FV<br />

Defines the value of the multiplier for the<br />

[Torque Ref B Sel] selection.<br />

➎<br />

Digital In6<br />

Digital In5<br />

Digital In4<br />

Digital In3<br />

Digital In2<br />

Digital In1<br />

Min/Max:<br />

Units:<br />

Related<br />

0<br />

0<br />

1<br />

2<br />

3<br />

“Ready”<br />

“Ready”<br />

“User Set 1”<br />

“User Set 2”<br />

“User Set 3”<br />

199<br />

Read Only 361<br />

thru<br />

366<br />

1 = Input Present<br />

0 = Input Not Present<br />

x = Reserved<br />

1.0<br />

–/+32767.0<br />

0.1<br />

➏<br />

053<br />

No.<br />

➊<br />

➋<br />

➌<br />

➍<br />

➎<br />

Description<br />

File – Lists the major parameter file category.<br />

Group – Lists the parameter group within a file.<br />

No. – Parameter number. Note that all parameters in the <strong>PowerFlex</strong> <strong>700</strong>VC are 32 bit.<br />

= Parameter value cannot be changed until drive is stopped.<br />

FV = Parameter only displayed when [Motor Cntl Sel] is set to “4.”<br />

Parameter Name & Description – Parameter name as it appears on an LCD HIM, with a brief<br />

description of the parameter’s function.<br />

Values – Defines the various operating characteristics of the parameter. Three types exist.<br />

ENUM Default: Lists the value assigned at the factory. “Read Only” = no default.<br />

Options: Displays the programming selections available.<br />

Bit Bit: Lists the bit place holder and definition for each bit.<br />

Numeric Default: Lists the value assigned at the factory. “Read Only” = no default.<br />

Min/Max: The range (lowest and highest setting) possible for the parameter.<br />

Units: Unit of measure and resolution as shown on the LCD HIM.<br />

Important: Some parameters will have two unit values:<br />

• Analog inputs can be set for current or voltage with [Anlg In Config], param. 320.<br />

• Setting [Speed Units], parameter 79 selects Hz or RPM.<br />

Important: When sending values through DPI ports, simply remove the decimal<br />

point to arrive at the correct value (i.e. to send “5.00 Hz,” use “500”).<br />

➏ Related – Lists parameters (if any) that interact with the selected parameter. The symbol “ ”<br />

indicates that additional parameter information is available in Appendix C.<br />

Publication 20B-UM002C-EN-P

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!