k SHORE POWER SWITCH OVER UNIT LAE 111<br />

CONNECTION LAE 111<br />

Wire cross section<br />

Wire cross section<br />

4 mm² for power supply<br />

min. 1,5 mm² for outputs A, B, C and D<br />

Power supply mains 230 Volt/50 Hz - shore power<br />

clamp 11 L1 (life - black) Connection of shore power<br />

clamp 12 N (neutral - blue) Connection of shore power<br />

clamp PE PE (protective earth conductor - green/yellow)<br />

Power supply onboard unit 230 Volt/50 Hz - generator/inverter<br />

clamp 11 L1 (life - black) Connection of generator/inverter<br />

clamp 12 N (neutral - blue) Connection of generator/inverter<br />

clamp PE PE (protective earth conductor - green/yellow)<br />

Output A<br />

switched through thermal circuit breaker “Hot Water” - 10A<br />

clamp 21 L1 (life - black) Connection of the water heater<br />

clamp 22 N (neutral - blue) Connection of the water heater<br />

clamp PE PE (protective earth conductor - green/yellow)<br />

Output B<br />

switched through thermal circuit breaker “Battery Charger” - 10A<br />

clamp 31 L1 (life - black) Connection of the battery charger<br />

clamp 32 N (neutral - blue) Connection of the battery charger<br />

clamp PE PE (protective earth conductor - green/yellow)<br />

Output A<br />

switched through thermal circuit breaker “Sockets” - 10A<br />

clamp 21 L1 (life - black) Connection of the sockets<br />

clamp 22 N (neutral - blue) Connection of the sockets<br />

clamp PE PE (protective earth conductor - green/yellow)<br />

Output B<br />

switched through thermal circuit breaker “Air Condition” - 10A<br />

clamp 31 L1 (life - black) Connection of the air condition<br />

clamp 32 N (neutral - blue) Connection of the air condition<br />

clamp PE PE (protective earth conductor - green/yellow)<br />

all outputs are protected by a fault-current circuit breaker RCBo 25 A (30 mA)<br />

Rear View LAE 111<br />

PE 62 61 PE 52 51 PE 42 41 PE 32 31 PE 22 21 PE 12 11<br />

Air Condition<br />

min. 3 x 1,5 mm²<br />

Sockets<br />

min. 3 x 1,5 mm²<br />

Battery Charger<br />

min. 3 x 1,5 mm²<br />

Hot Water<br />

min. 3 x 1,5 mm²<br />

Generat./Inverter<br />

3 x 4 mm²<br />

Shore<br />

3 x 4 mm²<br />

V1.4 - AUG 2013 Page 3