Chapter 1 - INTRODUCTION<br />

This Operator’s <strong>Manual</strong> contains detailed information and instructions which when adhered to ensure<br />

the safe and effective set up, use and simple maintenance of the <strong>LTV</strong> ® <strong>1200</strong> / 1150 ventilator.<br />

This manual is designed for use by Respiratory Therapists or other qualified and trained personnel<br />

under the direction of a physician and in accordance with applicable state laws and regulations. It<br />

contains the following:<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Ventilator Overview<br />

Installation and Checkout<br />

Using the Controls and Indicators<br />

Monitored Data<br />

Ventilator Alarms<br />

Extended Features<br />

Ventilator Checkout tests<br />

Operating Procedure<br />

Troubleshooting<br />

Cleaning, Disinfecting and Sterilizing<br />

Set Up / Maintenance<br />

Power and Battery Operation<br />

Service tests, calibration, and major maintenance operations are described in the <strong>LTV</strong> ® <strong>1200</strong>, 1150,<br />

and 1100 Ventilator Service <strong>Manual</strong> (P/N 18603-001).<br />

NOTE<br />

Pressure Support and Pressure Control breaths on the <strong>LTV</strong> ® <strong>1200</strong> / 1150 are compensated for<br />

PEEP. Delivered pressure is controlled by the Pressure Support or Pressure Control setting and is<br />

affected by the PEEP setting. For example, a Pressure Support setting of 20cmH 2 O and a PEEP<br />

setting of 10cmH 2 O results in a Peak Inspiratory Pressure (PIP) of 30cmH 2 O.<br />

REMARQUE<br />

La pression de support et le contrôle de la pression des respirations sur le <strong>LTV</strong> ® <strong>1200</strong> / 1150 sont<br />

compensés pour la pression expiratoire positive (PEP). La pression administrée est contrôlée par le<br />

réglage de la pression de support ou par le réglage du contrôle de la pression et elle dépend du<br />

réglage PEP. Par exemple, un réglage de la pression de support de 20 cmH 2 O et un réglage PEP de<br />

10 cmH 2 O donnent une pression inspiratoire maximale (PImax) de 30 cmH 2 O.<br />

Operator’s <strong>Manual</strong> <strong>LTV</strong> ® <strong>1200</strong> / 1150 Ventilators Page 1-1<br />

P/N 19802-001 Rev. F