Chapter 2 - VENTILATOR OVERVIEW<br />

The <strong>LTV</strong> ® <strong>1200</strong> / 1150 ventilator is a lightweight, high performance ventilator that is designed to<br />

provide the maximum functionality in the smallest possible package. The <strong>LTV</strong> ® <strong>1200</strong> / 1150 ventilator<br />

provides the following features:<br />

High performance ventilation in a small lightweight package (10.5” x 13.5” x 3.25”, 14.5 lbs).<br />

Turbine technology allows the ventilator to operate without an external compressed gas source.<br />

CPAP 4 , SIMV 5 , Control, Assist/Control and Apnea Backup ventilation modes.<br />

NPPV 6 mode ventilation.<br />

Volume Control, Pressure Control and Pressure Support ventilation.<br />

Spontaneous Breathing Trial (SBT) to assist with weaning and discontinuation of ventilatory support.<br />

Variable alarm settings including High Peak Pressure, Low Peak Pressure, Low Minute Volume,<br />

Apnea, High Breath Rate, High PEEP and Low PEEP.<br />

Oxygen Bleed-in from a Low-Pressure Oxygen source.<br />

Oxygen Blending from a High-Pressure Oxygen source, O 2 Flush, and O 2 Cylinder Duration (<strong>LTV</strong> ®<br />

<strong>1200</strong> only).<br />

Lockable front panel controls.<br />

Monitors for Breath Rate (f), I:E Ratio, MAP, Minute Ventilation (VE), PEEP, PIP and Tidal<br />

Volume (Vte).<br />

Real-time patient circuit pressure display with Peak Inspiratory Pressure indicator.<br />

Variable termination conditions for Pressure Support breaths, including maximum inspiratory time<br />

termination and percentage of peak flow.<br />

Selectable Percentage of Peak Flow termination for Pressure Control breaths.<br />

Presets to facilitate rapid patient set-up.<br />

Leak Compensation to improve triggering when a circuit leak is present.<br />

Single or dual tone output capabilities.<br />

Operation from a variety of power sources including AC power, internal battery and external DC<br />

power sources.<br />

4 Continuous Positive Airway Pressure<br />

5 Synchronized Intermittent Mandatory Ventilation<br />

6 Non-invasive Positive Pressure Ventilation<br />

Operator’s <strong>Manual</strong> <strong>LTV</strong> ® <strong>1200</strong> / 1150 Ventilators Page 2-1<br />

P/N 19802-001 Rev. F