A <strong>Closer</strong> <strong>Look</strong> <strong>at</strong> <strong>Prevailing</strong> <strong>Civil</strong> <strong>Engineering</strong> <strong>Practice</strong>, Wh<strong>at</strong>, Why and How<br />
Vincent T. H. CHU<br />
r<strong>at</strong>e of 50%. Therefore, when butterfly disc open from 40% to 50%, it also<br />
gener<strong>at</strong>es a change in flow r<strong>at</strong>e of 50%. If the flow r<strong>at</strong>e <strong>at</strong> 30% is 200m 3 /s,<br />
then the flow r<strong>at</strong>e of 40% and 50% open are 300m 3 /s and 450m 3 /s<br />
respectively.<br />
The use of different characteristics depends on the amount of pressure<br />
drop available to the butterfly value. Should more than 25% of system<br />
pressure drop is available to the butterfly value, then the employment of<br />
linear characteristic would provide the best results. On the contrary, if less<br />
than 25% of system pressure drop is available to the butterfly value, then<br />
the employment of equal percentage characteristic would be a better<br />
choice.<br />
12. Why is partial PVC lining instead of full lining adopted in concrete<br />
pipes<br />
The main function of PVC lining is to protect concrete surface against<br />
hydrogen sulfide <strong>at</strong>tack. Moreover, it also guards against <strong>at</strong>tack by a wide<br />
range of acids and alkalis. Hydrogen sulfide gener<strong>at</strong>ed in sewerage by<br />
bacterial action under anaerobic (absence of oxygen) conditions is<br />
converted to sulphuric acid by aerobic bacteria growing on wet sewer walls.<br />
This acid reacts with the lime in the concrete, causing breakdown of the<br />
concrete pipes. The addition of lining could also improve the flow capacity.<br />
Only the concrete above the line of minimum flow shall be <strong>at</strong>tacked by<br />
hydrogen sulfide and therefore PVC lining is needed above this flow line.<br />
For medium to large pipe sizes, partial lining of 300 degree with 60 degree<br />
pipe invert exposed proves to be effective against <strong>at</strong>tack. Small diameter<br />
pipe may warrant complete linings of pipes.<br />
75