<strong>Cable</strong> gl<strong>and</strong>s for Ex applications - Brass<br />
Klippon ® cable gl<strong>and</strong>s - Brass - Ex-e, Ex-d, IP 68 for armoured <strong>and</strong> non-armoured cables<br />
<strong>Cable</strong> entries<br />
All-purpose cable gl<strong>and</strong> for cables <strong>and</strong> lines with single-wire armouring,<br />
metal-foil armouring <strong>and</strong> braided armouring. Non-armoured cables <strong>and</strong> lines<br />
can also be connected.<br />
L<br />
L1<br />
SW<br />
D1<br />
D2<br />
C<br />
Thread<br />
Technical data<br />
Material<br />
Brass<br />
O-Ring / Seal insert<br />
Silicone / Silicone<br />
Temperature range -60 °C...180 °C<br />
Degree of protection<br />
IP 68 - 2.5 bar<br />
Water depth<br />
25 m (30 Min.)<br />
Type of armouring<br />
Single-wire armouring, Metal foil armouring, Braided armouring<br />
Approval<br />
ATEX ll 2 GD, Ex d llC / Ex e ll / Ex tD A21 IP68, IECEx Ex d IIC / Ex e ll<br />
Note<br />
Ordering data<br />
Type Thread D1 outer cable Ø D2 inner cable Ø <strong>Cable</strong> armour L/L1 SW MODR SUHB Qty. Order No.<br />
metric, brass<br />
KDSU M20 BS O SC 1 G16 M 20 x 1.5 6.70-10.30 3.40-8.40 0.15-1.25 78 / 16.00 25 32.5 L24 20 0930001211<br />
KDSU M20 BS O SC 2 G16 M 20 x 1.5 9.00-13.50 3.40-8.40 0.15-1.25 78 / 16.00 25 32.5 L24 20 0930001212<br />
KDSU M20 BS O SC 1 G20S M 20 x 1.5 9.40-12.50 7.20-11.70 0.15-1.25 78 / 16.00 25 32.5 L24 20 0930011213<br />
KDSU M20 BS O SC 2 G20S M 20 x 1.5 11.50-16.00 7.20-11.70 0.15-1.25 78 / 16.00 25 32.5 L24 20 0930011214<br />
KDSU M20 BS O SC 1 G20 M 20 x 1.5 12.00-17.60 9.40-14.00 0.15-1.25 78 / 16.00 30 32.5 EL30 20 0930021211<br />
KDSU M20 BS O SC 2 G20 M 20 x 1.5 15.50-21.10 9.40-14.00 0.15-1.25 78 / 16.00 30 32.5 EL30 20 0930021212<br />
KDSU M25 BS O SC 1 G25 M 25 x 1.5 20.30-27.40 20.00-20.00 0.15-1.6 90 / 16.00 38 50 EL38 20 0930031211<br />
KDSU M25 BS O SC 2 G25 M 25 x 1.5 20.30-27.40 20.00-20.00 0.15-1.6 90 / 16.00 38 50 EL38 20 0930031212<br />
KDSU M32 BS O SC 1 G32 M 32 x 1.5 26.70-34.00 19.50-26.30 0.15-2 105 / 16.00 46 80 EL46 10 0930041211<br />
KDSU M32 BS O SC 2 G32 M 32 x 1.5 26.70-34.00 19.50-26.30 0.15-2 105 / 16.00 46 80 EL46 10 0930041212<br />
KDSU M40 BS O SC 1 G40 M 40 x 1.5 28.60-36.20 23.00-32.20 0.2-2 113 / 16.00 55 80 EL55 10 1136870000<br />
KDSU M40 BS O SC 2 G40 M 40 x 1.5 28.60-36.20 23.00-32.20 0.2-2 113 / 16.00 55 80 EL55 10 0930051212<br />
KDSU M50 BS O SC 1 G50S M 50 x 1.5 39.40-46.70 28.10-38.20 0.3-2.5 125 / 16.00 65 100 EL65 1 0930061213<br />
KDSU M50 BS O SC 2 G50S M 50 x 1.5 39.40-46.70 28.10-38.20 0.3-2.5 125 / 16.00 65 100 EL65 1 1136880000<br />
KDSU M50 BS O SC 1 G50 M 50 x 1.5 41.10-48.50 33.10-44.10 0.3-2.5 125 / 16.00 65 100 EL65 1 1136890000<br />
KDSU M50 BS O SC 2 G50 M 50 x 1.5 45.70-53.20 33.10-44.10 0.3-2.5 125 / 16.00 65 100 EL65 1 1136910000<br />
KDSU M63 BS O SC 1 G63S M 63 x 1.5 47.50-54.80 9.20-50.10 0.3-2.5 125 / 19.00 80 160 EL80 1 1136920000<br />
KDSU M63 BS O SC 2 G63S M 63 x 1.5 52.10-59.50 39.20-50.10 0.3-2.5 125 / 19.00 80 160 EL80 1 1136930000<br />
KDSU M63 BS O SC 1 G63 M 63 x 1.5 53.80-61.20 46.70-56.00 0.3-2.5 125 / 19.00 80 160 EL80 1 1136940000<br />
KDSU M63 BS O SC 2 G63 M 63 x 1.5 58.40-65.80 46.70-56.00 0.3-2.5 125 / 19.00 80 160 EL80 1 1136950000<br />
KDSU M75 BS O SC 1 G75 M 75 x 1.5 66.50-73.40 58.00-68.00 0.3-2.5 131 / 19.00 90 200 EL90 1 1136980000<br />
KDSU M75 BS O SC 2 G75 M 75 x 1.5 66.50-73.40 58.00-68.00 0.3-2.5 131 / 19.00 90 200 EL90 1 0930111212<br />
KDSU M75 BS O SC 1 G75S M 75 x 1.5 60.20-68.00 52.10-62.00 0.3-2.5 131 / 19.00 90 200 EL90 1 1136960000<br />
KDSU M75 BS O SC 2 G75S M 75 x 1.5 64.80-72.20 52.10-62.00 0.3-2.5 131 / 19.00 90 200 EL90 1 1136970000<br />
Note<br />
• All cable gl<strong>and</strong>s have a pitch of 1.5 mm.<br />
• In Ex d applications, the cable gl<strong>and</strong>s used for internal thread must be in accordance with the requirements of section 5.3 of EN/IEC 60079-1. In the screwed in position, at least 5<br />
threads must be engaged.<br />
• If the cable gl<strong>and</strong>s are installed in non-metallic Ex e connection equipment, these must be connected to the protective earth of the system.<br />
• The connection cable must be laid securely to prevent being placed under a tensile load.<br />