ATEX directive 1999/92/EC<br />

Technical appendix<br />

The system of EPL classifications is shown below.<br />

Firedamp (methane) risk mines (Group I)<br />

EPL Ma<br />

Equipment for installation in a mine with a very high level of<br />

protection. Has sufficient safety that ensure there is no source<br />

of ignition even when the device is operated following an<br />

outbreak of gas.<br />

EPL Mb<br />

Equipment for installation in a mine with a high level of<br />

protection. Has sufficient safety to ensure that there is no source<br />

of ignition in the period of time between the outbreak of gas <strong>and</strong><br />

the time the equipment is switched off.<br />

Gases (Group II)<br />

EPL Ga<br />

Equipment for explosive-risk gas atmospheres with a very high<br />

level of protection. No source of ignition is present during normal<br />

operation or when errors occur that cannot be necessarily<br />

expected on a regular basis.<br />

Dust (Group III)<br />

EPL Da<br />

Equipment for combustible dust atmospheres with a very high<br />

level of protection. No source of ignition is present during normal<br />

operation or in very rare faults.<br />

EPL Db<br />

Equipment for combustible dust atmospheres with a high level<br />

of protection. No source of ignition is present during normal<br />

operation or when errors occur that cannot be necessarily<br />

expected on a regular basis.<br />

EPL Dc<br />

Equipment for combustible dust atmospheres with an elevated<br />

level of protection. No source of ignition is present during normal<br />

operation <strong>and</strong> it can have additional safeguards to ensure that<br />

none is present during faults which happen regularly (e. g. failure<br />

of a lamp).<br />

EPL Gb<br />

Equipment for explosive-risk gas atmospheres with a high level<br />

of protection. No source of ignition is present during normal<br />

operation or when errors occur that cannot be necessarily<br />

expected on a regular basis.<br />

EPL Gc<br />

Equipment for explosive-risk gas atmospheres with an elevated<br />

level of protection. No source of ignition is present during normal<br />

operation <strong>and</strong> it can have additional safeguards to ensure that<br />

none is present during faults which happen regularly (e. g. failure<br />

of a lamp).<br />