HPC-NNBOSL-U0-000-RES-000034 Version 2.0<br />
<strong>PSA</strong> <strong>of</strong> <strong>Accidents</strong> <strong>in</strong> <strong>the</strong> <strong>Spent</strong> <strong>Fuel</strong> <strong>Pool</strong><br />
NOT PROTECTIVELY MARKED<br />
The probability that <strong>the</strong> third PTR [FPCS] tra<strong>in</strong> is required at <strong>the</strong> same time as <strong>the</strong> EVU<br />
[CHRS] dur<strong>in</strong>g accident situations must be taken <strong>in</strong>to account for <strong>the</strong> situations <strong>in</strong>volv<strong>in</strong>g<br />
a loss <strong>of</strong> PTR [FPCS].<br />
In <strong>the</strong> light <strong>of</strong> <strong>the</strong> particular characteristics <strong>of</strong> <strong>the</strong> comb<strong>in</strong>ed scenarios 7 , an evaluation <strong>of</strong><br />
<strong>the</strong> <strong>in</strong>crease <strong>in</strong> <strong>the</strong> risk <strong>of</strong> reach<strong>in</strong>g boil<strong>in</strong>g and Unacceptable Consequences <strong>in</strong> <strong>the</strong> pool<br />
is carried out, assum<strong>in</strong>g that priority is always given to <strong>the</strong> EVU [CHRS] and that <strong>the</strong><br />
third tra<strong>in</strong> is deliberately deprived <strong>of</strong> heat s<strong>in</strong>k <strong>in</strong> core accidents.<br />
This evaluation shows that <strong>the</strong> impact on <strong>the</strong> risk is not significant (AS-0017).<br />
4.4.4 Results<br />
4.4.4.1 Overall Boil<strong>in</strong>g and <strong>Fuel</strong> Damage Frequency<br />
Boil<strong>in</strong>g follow<strong>in</strong>g <strong>the</strong> loss <strong>of</strong> cool<strong>in</strong>g <strong>of</strong> <strong>the</strong> <strong>Spent</strong> <strong>Fuel</strong> <strong>Pool</strong> may result from <strong>the</strong> follow<strong>in</strong>g<br />
<strong>in</strong>itiat<strong>in</strong>g events:<br />
Initiat<strong>in</strong>g Event<br />
Loss <strong>of</strong> PTR [FPCS] pump<br />
Loss <strong>of</strong> electrical supply<br />
Loss <strong>of</strong> Offsite Power (24h)<br />
Loss <strong>of</strong> PTR [FPCS] header<br />
Loss <strong>of</strong> Cool<strong>in</strong>g Cha<strong>in</strong><br />
Loss <strong>of</strong> Ultimate Heat S<strong>in</strong>k<br />
Boil<strong>in</strong>g<br />
/r.y<br />
7.23E-05<br />
8.48E-06<br />
1.17E-05<br />
2.20E-07<br />
1.96E-04<br />
9.45E-07<br />
Total (boil<strong>in</strong>g) 2.90 E-04<br />
The distribution <strong>of</strong> <strong>the</strong> risk <strong>of</strong> boil<strong>in</strong>g by <strong>in</strong>itiat<strong>in</strong>g event is shown below:<br />
7<br />
The IRWST cannot be used as a makeup device for <strong>the</strong> PTR [FPPS/FPCS] dur<strong>in</strong>g core accidents as <strong>the</strong> water is needed to manage<br />
<strong>the</strong> accident <strong>in</strong> <strong>the</strong> reactor build<strong>in</strong>g.<br />
UNCONTROLLED WHEN PRINTED<br />
NOT PROTECTIVELY MARKED<br />
Page 18 <strong>of</strong> 37