Measurement Functions<br />
vu + PPM<br />
<strong>ML1</strong> provides vu + PPM (Peak Program Meter) measurement results,<br />
following IEC60268.<br />
Reference<br />
Level<br />
Numerical<br />
Peak-Hold<br />
Graphical<br />
Peak-Hold<br />
Integration Time<br />
Reference Indicator<br />
Fig 3.11 vu + PPM (Type I) Panel<br />
The PPM may be measured according to three standards:<br />
• Type I<br />
• Type IIA<br />
• Nordic standard<br />
One of these standards has to be selected when entering the vu+PPM<br />
mode through the measurement functions menu.<br />
The following chapters describe the different entry fields and indicators<br />
of the vu+PPM display.<br />
a. Reference Level & Indicator<br />
The reference level indicates the RMS level of a 1 kHz sine wave that<br />
defines the value of the reference indicator. The reference level may<br />
be defined by the user in a range of -20 dBu to +14 dBu.<br />
The default reference level depends on the selected standard<br />
• +4 dBu for the vu-meter<br />
• +6 dBu for the PPM standards Type I and Nordic<br />
• +8 dBu for the PPM standard Type IIA.<br />