Appendix A: I/O Address Function<br />
Delay Time Setting<br />
I/O port : 0EE7H<br />
Bit7 Power On Delay<br />
0 Disable(*)<br />
1 Enable<br />
Bit6 Power Off Delay<br />
0 Disable(*)<br />
1 Enable<br />
Delay On Time Setting<br />
Bit3~5 Function Description<br />
000 10 sec<br />
001 30 sec<br />
010 1 min<br />
011 5 min<br />
100 10 min<br />
101 15 min<br />
110 30 min<br />
111 1 hour<br />
Delay Off Time Setting<br />
Bit 2~0 Time (sec)<br />
000 20 sec<br />
001 1 min<br />
010 5 min<br />
011 10 min<br />
100 30 min<br />
101 1 hour<br />
110 6 hour<br />
111 18 hour<br />
Copyright © 2012 <strong>NEXCOM</strong> International Co., Ltd. All rights reserved 34<br />
nROK 3000 User Manual