Appendix A: I/O Address Function<br />

Delay Time Setting<br />

I/O port : 0EE7H<br />

Bit7 Power On Delay<br />

0 Disable(*)<br />

1 Enable<br />

Bit6 Power Off Delay<br />

0 Disable(*)<br />

1 Enable<br />

Delay On Time Setting<br />

Bit3~5 Function Description<br />

000 10 sec<br />

001 30 sec<br />

010 1 min<br />

011 5 min<br />

100 10 min<br />

101 15 min<br />

110 30 min<br />

111 1 hour<br />

Delay Off Time Setting<br />

Bit 2~0 Time (sec)<br />

000 20 sec<br />

001 1 min<br />

010 5 min<br />

011 10 min<br />

100 30 min<br />

101 1 hour<br />

110 6 hour<br />

111 18 hour<br />