This is how the exhaust gas recirculation rate is<br />

determined<br />

Using the air-mass flow meter, the engine control<br />

unit measures the intake fresh air mass and<br />

calculates from this the corresponding intake<br />

manifold pressure. If exhaust gas is fed in via the<br />

exhaust gas recirculation system, then the fresh<br />

air mass is increased by the exhaust gas intake<br />

and the intake manifold pressure rises. The<br />

intake manifold pressure sender measures this<br />

pressure and sends a corresponding voltage<br />

signal to the engine control unit.<br />

The total quantity (fresh air+exhaust gas) is<br />

determined from this signal.<br />

The engine control unit subtracts the fresh air<br />

mass from this total quantity and thus obtains the<br />

exhaust gas quantity.<br />

The advantage is that the exhaust gas<br />

recirculation rate can be raised closer to the<br />

operating limit.<br />

Air-mass flow meter G70<br />

intake air temperature sender G42<br />

Sensor for<br />

pressure sender G71<br />

<strong>Motronic</strong> control unit J220<br />

EGR valve N18<br />

Exhaust gas recirculation<br />

potentiometer G212<br />

253_134<br />

Signal failure strategies<br />

If the intake manifold pressure sender fails, then<br />

the exhaust gas quantity is calculated by the<br />

engine control unit and the exhaust gas<br />

recirculation rate is reduced in relation to the<br />

map.<br />