This is how the exhaust gas recirculation rate is<br />
determined<br />
Using the air-mass flow meter, the engine control<br />
unit measures the intake fresh air mass and<br />
calculates from this the corresponding intake<br />
manifold pressure. If exhaust gas is fed in via the<br />
exhaust gas recirculation system, then the fresh<br />
air mass is increased by the exhaust gas intake<br />
and the intake manifold pressure rises. The<br />
intake manifold pressure sender measures this<br />
pressure and sends a corresponding voltage<br />
signal to the engine control unit.<br />
The total quantity (fresh air+exhaust gas) is<br />
determined from this signal.<br />
The engine control unit subtracts the fresh air<br />
mass from this total quantity and thus obtains the<br />
exhaust gas quantity.<br />
The advantage is that the exhaust gas<br />
recirculation rate can be raised closer to the<br />
operating limit.<br />
Air-mass flow meter G70<br />
intake air temperature sender G42<br />
Sensor for<br />
pressure sender G71<br />
<strong>Motronic</strong> control unit J220<br />
EGR valve N18<br />
Exhaust gas recirculation<br />
potentiometer G212<br />
253_134<br />
Signal failure strategies<br />
If the intake manifold pressure sender fails, then<br />
the exhaust gas quantity is calculated by the<br />
engine control unit and the exhaust gas<br />
recirculation rate is reduced in relation to the<br />
map.<br />