If the network node identifies a COLLISION following selection<br />
(without wildcards), a conflict of address may exist. This means that<br />
the same device ID is used in two meters. In a case of this kind,<br />
extended selection, which takes the fabrication number into account,<br />
would be helpful. (See also Page 20.)<br />
(Hex)<br />
Extended Select<br />
Code<br />
CI Field 1 52<br />
Device ID (4th byte) 2 78 Device ID = 12345678<br />
Device ID (3rd byte) 3 56<br />
Device ID (2nd byte) 4 34<br />
Device ID (1st byte) 5 12<br />
Manufacturer (2nd<br />
byte)<br />
Manufacturer (1st<br />
byte)<br />
6 65 Manufacturer ID "LSE" =<br />
12901 (decimal)<br />
7 32<br />
Version 8 01 Software version = 01<br />
Medium 9 08 Heat cost allocator<br />
DIF 10 0C<br />
VIF 11 78<br />
Device ID (4th byte) 12 32 Fabrication number=<br />
98765432<br />
Device ID (3rd byte) 13 54<br />
Fabrication<br />
number(2nd byte)<br />
14 76<br />
Fabrication<br />
number(1st byte)<br />
15 98<br />
Set Baud Rate<br />
Using the CI fields listed in the table, the baud rate can be set at the<br />
RS-232 interface. Owing to the fact that the baud rate is<br />
automatically recognized and set, any baud rate setting through the<br />
M-bus will be ignored.<br />
CI Field (Hex) B8 B9 BA BB BC BD<br />
Baud rate 300 600 1200 2400 4800 9600<br />