Description<br />
TSX P57 104M<br />
TSX P57 204M/304M<br />
TSX P57 0244M<br />
Presentation:<br />
page 1/4<br />
8<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
7<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
TSX P57 154M<br />
TSX P57 254M/354M/454M<br />
Memory structure:<br />
pages 1/8 …<br />
<strong>Modicon</strong> <strong>Premium</strong><br />
automation <strong>platform</strong><br />
Unity processors<br />
Description<br />
TSX P57pp4M processors without integrated Ethernet port<br />
TSX P57 1p4M single-format processors and TSX P57 2p4/3p4M double-format<br />
processors feature the following on the front panel:<br />
1 A display block with 5 LEDs:<br />
v RUN LED (green): Processor in operation (program running)<br />
v ERR LED (red): Fault on the processor or its on-board devices (PCMCIA memory<br />
card and PCMCIA communication card)<br />
v I/O LED (red): Faults occurring on another station module or configuration fault<br />
v TER LED (yellow): Activity on TER or AUX terminal port<br />
v FIP LED (red): Activity on integrated Fipio bus (depending on model)<br />
2 RESET button causing a cold restart of the PLC when it is activated<br />
3 An 8-way female mini-DIN connector marked TER for connecting a programming<br />
or adjustment terminal (RS 485)<br />
4 An 8-way female mini-DIN connector marked AUX for connecting a programming,<br />
adjustment or operator dialogue terminal (RS 485)<br />
5 A PCMCIA slot (no. 0) for a memory card<br />
6 A PCMCIA slot (no. 1) for a communication card or memory extension card for<br />
storing additional data<br />
7 A 9-way SUB-D connector (on TSX P57 154/254/354M models) for Fipio bus<br />
communication (Fipio manager port)<br />
8 An air recirculating heatsink (on TSX P57 0244/1p4M models)<br />
Processor with integrated CANopen port<br />
The TSX P57 0244M processor feature all or some of the following:<br />
1 A display block with 4 LEDs:<br />
v RUN LED (green): Processor in operation (program running)<br />
v ERR LED (red): Fault on the processor or its on-board devices (PCMCIA memory<br />
card and PCMCIA communication card)<br />
v I/O LED (red): Faults occurring on another station module or configuration fault<br />
v TER LED (yellow): Activity on TER or AUX terminal port<br />
2 RESET button causing a cold restart of the PLC when it is activated<br />
3 An 8-way female mini-DIN connector marked TER for connecting a programming<br />
or adjustment terminal (RS 485)<br />
4 An 8-way female mini-DIN connector marked AUX for connecting a programming,<br />
adjustment or operator dialogue terminal (RS 485)<br />
5 A PCMCIA slot (no. 0) for a memory card<br />
6 A PCMCIA slot (no. 1) equipped with PCMCIA CANopen master V4.02 card,<br />
complete with cordset and tap junction (see page 5/65)<br />
7 An air recirculating heatsink.<br />
Characteristics:<br />
pages 1/10 …<br />
References:<br />
pages 1/12 …<br />
PCMCIA references:<br />
pages 1/22 …<br />
1/5<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10