h Technical Product Data Gravity Pipe Systems PN 1 - Hobas
h Technical Product Data Gravity Pipe Systems PN 1 - Hobas
h Technical Product Data Gravity Pipe Systems PN 1 - Hobas
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Special Couplings<br />
The assembly coupling consists of a stainless steel sleeve with<br />
a screw connection and rubber seal made of EPDM (NBR also<br />
possible on request).<br />
DN<br />
Assembly Couplings Adapter Coupling<br />
Assembly Coupling: Adapter Coupling:<br />
de LC DEC GRP PVC LC<br />
[mm] [mm] [mm]<br />
DN DN [mm]<br />
150 168 110 205 150 150 180<br />
200 220 141 301 200 200 180<br />
250 272 141 349 250 250 180<br />
300 324 141 397 300 300 180<br />
350 376 141 447<br />
400 427 141 496<br />
500 530 141 595<br />
600 616 141 679<br />
700 718 141 779<br />
800 820 141 880<br />
900 924 141 983<br />
1000 1026 141 1076<br />
1100 1099 212 1170 de LC<br />
DN<br />
1200 1229 212 1299 [mm] [mm]<br />
1280 1280 212 1359 150 150-175 120<br />
1400 1434 212 1503 200 200-225 150<br />
1500 1499 212 1568 250 250-275 150<br />
1600 1638 212 1706 300 305-335 185<br />
1720 1720 212 1788 350 355-385 185<br />
1800 1842 212 1910 400 405-430 185<br />
2000 2047 212 2114 500 510-540 185<br />
2160 2160 310 2227 600 590-620 185<br />
2200 2250 310 2313<br />
2400 2400 310 2467<br />
2555 2555 310 2622<br />
2740 2740 310 2807<br />
3000 3000 310 3066<br />
3600 3600 310 3666<br />
Source: Straub Werke AG 2012<br />
Sleeve Coupling<br />
The DC-Coupling is fitted on one side to the PVC-mat,<br />
hence can be used as adapter coupling GRP/ PVC.<br />
Sleeve Coupling:<br />
Coupling system e.g. from FlexSeal for later assembly of<br />
gravity pipes. Suitable for connecting different pipe<br />
material.<br />
Source: Flexseal 10/2010<br />
All figures quoted are values and may slightly vary due to manufacturing tolerances. The information and recommendations reflect the state of our knowledge at the time of publication/update. Therefore the provided data cannot be construed as an express or implied warranty. All details must<br />
be checked and if necessary agreed to in each individual case. HOBAS cannot accept any liability. This also applies to errors, omissions and changes to technical data without notice.<br />
B02<br />
PIPE JOINTS