01.02.2015 Views

Beam extraction - 50th anniversary of the CERN Proton Synchrotron

Beam extraction - 50th anniversary of the CERN Proton Synchrotron

Beam extraction - 50th anniversary of the CERN Proton Synchrotron

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

shortening <strong>of</strong> <strong>the</strong> usable flat top in <strong>the</strong> septum currents. Therefore half <strong>the</strong> choke inductance was<br />

sometimes used.<br />

Fig. 5: Left: <strong>the</strong> <strong>extraction</strong> area. Right: beam and septum magnet positions.<br />

The efficiency <strong>of</strong> <strong>extraction</strong> during <strong>the</strong> first tests was <strong>of</strong> <strong>the</strong> order <strong>of</strong> 50%, limited by <strong>the</strong> thickness<br />

<strong>of</strong> <strong>the</strong> septum <strong>of</strong> <strong>the</strong> extractor magnet. However, <strong>the</strong> resonant <strong>extraction</strong> was shown to be possible and it<br />

was decided to implement it towards <strong>the</strong> East Hall. The time structure <strong>of</strong> <strong>the</strong> burst was still poor owing to<br />

<strong>the</strong> imperfect regulation <strong>of</strong> power supplies at that time. The oscillogram <strong>of</strong> <strong>the</strong> spill and o<strong>the</strong>r relevant<br />

parameters is shown on Fig. 6.<br />

Fig. 6: Oscillogram <strong>of</strong> beam burst for SS01 integer <strong>extraction</strong><br />

In 1965 an integer resonance <strong>extraction</strong> was installed with an <strong>extraction</strong> septum in SS58, shared<br />

with <strong>the</strong> fast <strong>extraction</strong>. One year after, <strong>the</strong> system was overhauled and <strong>the</strong> <strong>extraction</strong> septum was<br />

installed in SS62. The efficiency had improved but was still lower than 80%, causing heavy losses on <strong>the</strong><br />

septum. The external target 64 soon disappeared and physicists received <strong>the</strong>ir particles from external<br />

targets.<br />

In 1967, <strong>the</strong> efficiency was fur<strong>the</strong>r improved by means <strong>of</strong> <strong>the</strong> installation <strong>of</strong> a thin septum magnetic<br />

lens, 0.2 mm thick, in SS79.<br />