Control Codes<br />

Function Redefine User Store Termination Character<br />

ASCII<br />

[ESC] [EM] T <br />

Hexadecimal 1BH 19H 54H <br />

Decimal <br />

IPCL<br />

&%UT <br />

EPOS<br />

None<br />

Description This command allows the terminator used to signal the end of the<br />

name field in User Store commands to be modified. The value of is used<br />

(in addition to the ) for the terminator. The value of n may be from 0 to<br />

255.<br />

The default value for the second terminator is &. If this command redefines<br />

the terminator to something other than &, the & will no longer function.<br />

Example If &%UT% were sent to the printer, the user store command to run<br />

macro “Demo” would be &%URDemo%.<br />

Legacy User Macros<br />

The following commands are provided for legacy support. They are not<br />

intended for new applications.<br />

[ESC] g <br />

Process user macro<br />

ASCII [ESC] g <br />

Hexadecimal 1BH 67H 00H<br />

Decimal <br />

IPCL<br />

&%GP<br />

EPOS [ESC] g <br />

Description The [ESC] g command prints the user-store data buffer.<br />

[ESC] g <br />

Start macro record<br />

ASCII [ESC] g <br />

Hexadecimal 1BH 67H 01H<br />

Decimal <br />

IPCL<br />

&%GS<br />

EPOS ESC] g <br />

Description The [ESC] g command clears the user-store data buffer and<br />

begins recording data. The next 2000 bytes (including characters and<br />

commands) are recorded.<br />

<strong>43</strong>-06938 Rev L Page 125