28.02.2015 Views

Ithaca 610 Programmer's Guide - TransAct

Ithaca 610 Programmer's Guide - TransAct

Ithaca 610 Programmer's Guide - TransAct

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Programming Codes<br />

<strong>Ithaca</strong> ® <strong>610</strong> Programmer’s <strong>Guide</strong><br />

Function Select Paper Sensor(s) to Output Paper-End Signals<br />

ASCII [ESC] c 3 <br />

Hexadecimal 1BH 63H 33H <br />

Decimal <br />

Range 0 n 255<br />

Description ESC c 3 n selects whether to output paper-end signals or not to a parallel<br />

interface. The default setting is n=15. The paper roll low, paper roll end, and<br />

validation sensors can be selected. When the sensors are selected to output<br />

signals and any sensor detects a paper-end, the paper-end signal is output.<br />

When all sensors are disabled, and a paper out is detected, status is always a<br />

paper present. The paper roll low sensor is enabled when either bit 0 or bit 1 or<br />

both is on. The paper roll end sensor is enabled when either 2 or 3 or both bits is<br />

on. The validation sensor is enabled when either 6 or 7 or both bits are on. This<br />

command is enabled only with a parallel interface and is ignored with a serial<br />

interface.<br />

The paper sensor(s) used to output paper-end signals are selected by using n as<br />

follows:<br />

Bit Off/On Hex Decimal Function<br />

0 Off 00 0 Paper roll low sensor disabled.<br />

On 01 1 Paper roll low sensor enabled.<br />

1 Off 00 0 Paper roll low sensor disabled<br />

On 04 2 Paper roll low sensor enabled.<br />

2 Off 00 0 Paper roll end sensor disabled.<br />

On 04 4 Paper roll end sensor enabled.<br />

3 Off 00 0 Paper roll end sensor disabled.<br />

On 08 8 Paper roll end sensor enabled.<br />

4-5 — — — Undefined.<br />

6 Off 00 0 Validation sensor disabled.<br />

On 40 64 Validation sensor enabled.<br />

7 Off 00 0 Validation sensor disabled.<br />

On 80 128 Validation sensor enabled.<br />

Table 30 Paper Sensor Commands<br />

Note: Bits 0,1,2 and 3 all control the receipt station.<br />

Page 184 Rev D 28-05897