"WINNER II Channel Models", ver 1.1, Sept
"WINNER II Channel Models", ver 1.1, Sept
"WINNER II Channel Models", ver 1.1, Sept
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>WINNER</strong> <strong>II</strong> D<strong>1.1</strong>.2 V<strong>1.1</strong><br />
7 15 -4.1 -60 -55 -17.1<br />
8 20 -8.2 85 -78 -21.2<br />
9 20 25 30 -3.0 -5.2 -7.0 0 0 -13.0<br />
10 35 40 45 -4.6 -6.8 -8.6 -104 95 -14.6<br />
11 80 -10.0 95 86 -23.0<br />
12 85 -12.1 -104 95 -25.1<br />
13 110 -12.4 -105 -96 -25.4<br />
14 115 -11.8 103 -94 -24.8<br />
15 150 -20.4 -135 123 -33.4<br />
16 175 -16.6 -122 -111 -29.6<br />
Figure 6-2: PDP and frequency correlation (FCF) of CDL model.<br />
6.2 A2/B4 – Indoor to outdoor / outdoor to indoor<br />
Table 6-3 Scenario A2/B4: NLOS Clustered delay line model, indoor to outdoor environment.<br />
Cluster # Delay [ns] Power [dB] *AoD [º] *AoA [º] Ray power [dB]<br />
1 0 5 10 -3.0 -5.2 -7.0 0 0 -13.0<br />
2 0 -8.7 102 32 -21.7<br />
3 5 -3.7 -66 -21 -16.7<br />
4 10 -11.9 -119 37 -24.9<br />
5 35 -16.2 139 -43 -29.2<br />
6 35 -6.9 91 28 -19.9<br />
7 65 70 75 -3.4 -5.6 -7.3 157 -49 -13.4<br />
8 120 -10.3 -111 -34 -23.3<br />
9 125 -20.7 157 -49 -33.7<br />
10 195 -16.0 138 43 -29.1<br />
11 250 -21.0 158 49 -34.0<br />
12 305 -22.9 165 51 -35.9<br />
* AoD refer to angles of the indoor terminal and AoA refer to outdoor terminal<br />
** Cluster ASD refer to indoor terminal and Cluster ASA refer to outdoor terminal<br />
** Cluster ASD = 8º<br />
** Cluster ASA = 5º<br />
XPR = 9 dB<br />
Figure 6-3: PDP and frequency correlation (FCF) of CDL model.<br />
Page 62 (82)