Door Entry<br />
SELECTION TABLES FOR AUDIO DOOR ENTRY CONTROL EQUIPMENT<br />
CONTROL EQUIPMENT FOR<br />
LYNEA AUDIO HANDSETS<br />
NUMBER OF NUMBER OF LYNEA HANDSETS PER FLAT<br />
ENTRANCES 1 2 3 4 5 6 7<br />
1 1xHA/200 1xHA/200 1xHA/200 1xHA/200 1xHA/200 1xHA/200 1xHA/200<br />
1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N<br />
1xBC/200 1xBC/200 1xBC/200 1xBC/200<br />
1xAS/200 1xAS/200 1xAS/200 1xAS/200<br />
2 2xHA/200 2xHA/200 2xHA/200 2xHA/200 2xHA/200 2 X HA/200 2xHA/200<br />
1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N<br />
1xSI/200 1xSI/200 1xSI/200 1xSI/200 1xSI/200 1xSI/200 1xSI/200<br />
1xBC/200 1xBC/200 1xBC/200 1xBC/200<br />
1xAS/200 1xAS/200 1xAS/200 1xAS/200<br />
3 3xHA/200 3xHA/200 3xHA/200 3xHA/200 3xHA/200 3xHA/200 3xHA/200<br />
1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N 1xA/200N<br />
1xPSU/12V-1A 1xPSU/12V-1A 1xPSU/12V-1A 1xPSU/12V-1A 1xPSU/12V-1A 1xPSU/12V-1A 1xPSU/12V-1A<br />
2xSI/200 2xSI/200 2xSI/200 2xSI/200 2xSI/200 2xSI/200 2xSI/200<br />
1xBC/200 1xBC/200 1xBC/200 1xBC/200<br />
1xAS/200 1xAS/200 1xAS/200 1xAS/200<br />
Please Note: If using DDA entry panels, replace the HA/200 audio module with AZ/98DDA<br />
Please Note: The PSU/12V-1A is replaced with a PSU/12V-2A for multiple entrances with keypad entry panel<br />
CONTROL EQUIPMENT FOR<br />
NOVA AUDIO RECEIVERS<br />
NUMBER OF NUMBER OF NOVA RECEIVERS PER FLAT<br />
ENTRANCES 1 2 3 4 5 6 7<br />
1 1xHA/200 1xHA/200 1xHA/200 1xHA/200 1xHA/200 1xHA/200 1xHA/200<br />
1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200<br />
1xBC/200 1xBC/200 1xBC/200 1xBC/200<br />
1xAS/200 1xAS/200 1xAS/200 1xAS/200<br />
1xVCE/200 1xVCE/200<br />
2 2xHA/200 2xHA/200 2xHA/200 2xHA/200 2xHA/200 2 X HA/200 2xHA/200<br />
1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200<br />
1xVSI/200 1xVSI/200 1xVSI/200 1xVSI/200 1xVSI/200 1xVSI/200 1xVSI/200<br />
1xBC/200 1xBC/200 1xBC/200 1xBC/200<br />
1xAS/200 1xAS/200 1xAS/200 1xAS/200<br />
1xVCE/200 1xVCE/200<br />
3 3xHA/200 3xHA/200 3xHA/200 3xHA/200 3xHA/200 3xHA/200 3xHA/200<br />
1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200 1xVA/200<br />
2xVSI/200 2xVSI/200 2xVSI/200 2xVSI/200 2xVSI/200 2xVSI/200 2xVSI/200<br />
1xVCE/200 1xVCE/200 1xVCE/200 1xVCE/200 1xVCE/200<br />
1xBC/200 1xBC/200 1xBC/200 1xBC/200<br />
1xAS/200 1xAS/200 1xAS/200 1xAS/200<br />
Please Note: Nova cannot be used with DDA entry panels<br />
SYSTEM EXAMPLE<br />
3 x flats with two entrances (back door and front door)<br />
3 x standard Lynea handsets required in each flat (9 in total)<br />
Surface vandal resistant entry panel required at each entrance<br />
1 Select an audio entry panel 2 x VRA/3<br />
2 x VRSH/1<br />
2 Selected the required quantity of audio handsets or receivers 9 x YC/200UK<br />
3 Ascertain control equipment required from the tables above 2 x HA/200<br />
1 x A/200N<br />
1 x SI/200<br />
To ascertain control equipment necessary<br />
for your installation<br />
1 Select nu<strong>mb</strong>er of entrances<br />
2 Select nu<strong>mb</strong>er of handsets/receivers<br />
required per flat<br />
3 Read off material from field where<br />
row and column meet<br />
To ascertain control equipment necessary<br />
for your installation<br />
1 Select nu<strong>mb</strong>er of entrances<br />
2 Select nu<strong>mb</strong>er of handsets/receivers<br />
required per flat<br />
3 Read off material from field where<br />
row and column meet<br />
Contact your local branch or<br />
Systems Engineer for further information<br />
127