Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
INSTALL INSTRUCTIONS<br />
If YOU can IMAGINE it... WE can BUILD it<br />
STANDARD FRAME
WARNING!<br />
The safe installation and use of commercial tenting products can vary from site to site and during varying climactic<br />
conditions. Careful consideration should be paid to any installation during windy conditions and shall be monitored<br />
throughout the duration of the installation. Periodic maintenance and monitoring of the installation by the installer is<br />
required. Techniques other than those specified in this document may be required during these types of conditions.<br />
Users and installers shall indemnify and hold harmless <strong>Aztec</strong> Tent for any claim resulting from the improper installation<br />
and/or maintenance of this unit.<br />
Soil conditions also vary from site to site. The included anchoring package for this tent may need to be supplemented<br />
with alternate anchoring during windy conditions and in areas with questionable soil holding power. Full product<br />
engineering may be available.<br />
NOTICE<br />
This tent product is not intended to be used as a shelter from severe weather. <strong>Aztec</strong> assumes no liability for such use.<br />
An evacuation plan for the area covered within this tented space is imperative and shall be thoroughly posted for all<br />
users and potential occupants of the tent. Severe weather including electrical storm systems, moderate to severe<br />
wind, heavy rains, snow, or any condition that raises any doubt to the structural integrity of the tent are immediate<br />
signs that an evacuation is necessary. Severe bodily injury and/or death can occur.<br />
The installation of electrical, plumbing, lighting, appliances and/or HVAC equipment are not covered within this manual.<br />
Users/<strong>Install</strong>ers shall follow local code requirements for the installation of these items using certified personnel.<br />
<strong>Aztec</strong> Tents shall be indemnified and held harmless from any such use or injury resulting from its use.<br />
***IMPORTANT SAFETY INFORMATION***<br />
Proper personnel safety equipment should be worn at all times during the<br />
installation of any tenting products.<br />
Hard Hat<br />
Safety Glasses<br />
Work Gloves<br />
Long Pants<br />
Steel Toe Boots<br />
OSHA Approved Harness and restraint system (for off<br />
ground activities)<br />
www.aztectents.com
Thank you for your recent purchase from <strong>Aztec</strong> Tents. The following procedures will help you through your installation. If<br />
you ever run into problems with the installation of your <strong>Aztec</strong> Tent give one of our sales/service professionals a call. A<br />
complete listing of sales, service, and operational support is always available on our website at www.aztectents.com.<br />
Contents<br />
10’x <strong>Install</strong> Instructions 4-5<br />
15’x <strong>Install</strong> Instructions 6-7<br />
20’x <strong>Install</strong> Instructions 8-10<br />
30’x <strong>Install</strong> Instructions 11-14<br />
40’x <strong>Install</strong> Instructions 15-18<br />
Qwik Top Option Instructions 19<br />
Diagrams 20-33<br />
Replacement Parts 34<br />
Parts Photos 35<br />
Questions? Call us.<br />
<strong>Aztec</strong> Tents<br />
2665 Columbia Street<br />
Torrance, CA 90503 USA<br />
Direct (310) 347-3010<br />
Toll Free (800) 228-3687<br />
Fax (310) 381-0722<br />
www.aztectents.com
<strong>Install</strong>ation- 10’ Wide<br />
Step 1:<br />
Lay out four (4) corner fittings and four (4-White 9' 4") (A)<br />
spreader pipe to form perimeter frame. Layout (4) hip rafters<br />
(Yellow 6’10”) “B” on the ground and place the 4pt Crown in the<br />
center of the tent.<br />
Step 2:<br />
Start assembling the frame by inserting and pinning the four hip<br />
rafter poles to the 4pt Crown. Connect the corner fittings to the<br />
bottom of the rafter pipes.<br />
Step 3:<br />
Start at one corner of the tent and connect and pin the corner<br />
fitting to the perimeter pipe.<br />
Step 4:<br />
Continue by connecting and pinning the perimeter pipe to this<br />
corner and work your way around the tent connecting all of the<br />
perimeter pipes and corner fittings until all of the upper framing<br />
is connected and pinned.<br />
www.aztectents.com
Step 5:<br />
Layout the tent top over the frame and use the buckles on the<br />
underside of the top to attach to the frame. Secure the two<br />
buckles closest to the corner fitting first then tighten the<br />
remainder of the buckles. You may want to lay out a ground<br />
cloth at this time to prevent damage to the tent top when it<br />
touches the ground.<br />
Step 6:<br />
Lift up one side of the tent off the ground and slide two of the<br />
leg pipes over the corner fitting and pin into place.<br />
Step 7:<br />
Lift up the other side of the tent and install and pin the leg<br />
pipes on the other two corner fittings.<br />
Step 8:<br />
Anchor the tent with the included stakes and ropes. The ropes<br />
should be tied around each of the perimeter fittings with an<br />
overhand slip knot. The stakes should be driven approximately<br />
six (6) feet away from the bottom of the leg. To achieve proper<br />
rope tension, drive each stake approximately 24” into the<br />
ground with a sledge hammer. Tie the rope to the stake with a<br />
clove hitch and continue driving the stake into the ground until<br />
the rope is tight.<br />
www.aztectents.com
<strong>Install</strong>ation- 15’ Wide<br />
Step 1:<br />
Lay out four (4) corner fittings and four (4- 14' 4") spreader pipe<br />
to form perimeter frame. Layout (4) hip rafters (10’6”) on the<br />
ground and place the 4pt Crown in the center of the tent.<br />
Step 2:<br />
Start assembling the frame by inserting and pinning the four hip<br />
rafter poles to the 4pt Crown. Connect the corner fittings to the<br />
bottom of the rafter pipes.<br />
Step 3:<br />
Start at one corner of the tent and connect and pin the corner<br />
fitting to the perimeter pipe.<br />
Step 4:<br />
Continue by connecting and pinning the perimeter pipe to this<br />
corner and work your way around the tent connecting all of the<br />
perimeter pipes and corner fittings until all of the upper framing<br />
is connected and pinned.<br />
www.aztectents.com
Step 5:<br />
Carefully layout the tent top over the frame and use the buckles<br />
on the underside of the top to attach to the frame. Secure the<br />
two buckles closest to the corner fitting first then tighten the<br />
remainder of the buckles. You may want to lay out a ground<br />
cloth at this time to prevent damage to the tent top when it<br />
touches the ground.<br />
**Dragging the top fabric on the ground, or pulling hard over<br />
frame parts can damage, tear, and scratch the fabric. Be careful<br />
with your fabric.<br />
Step 6:<br />
Lift up one side of the tent off the ground and slide two of the<br />
leg pipes over the corner fitting and pin into place.<br />
Step 7:<br />
Lift up the other side of the tent and install and pin the leg<br />
pipes on the other two corner fittings.<br />
Step 8:<br />
Anchor the tent with the included stakes and ropes. The ropes<br />
should be tied around each of the perimeter fittings with an<br />
overhand slip knot. The stakes should be driven approximately<br />
six (6) feet away from the bottom of the leg. To achieve proper<br />
rope tension, drive each stake approximately 24” into the<br />
ground with a sledge hammer. Tie the rope to the stake with a<br />
clove hitch and continue driving the stake into the ground until<br />
the rope is tight.<br />
www.aztectents.com
<strong>Install</strong>ation- 20’ Wide<br />
Step 1:<br />
Lay out four (4) corner fittings and eight (8- 9' 4") spreader pipe<br />
to form perimeter frame. Lay out (4) hip rafters (14’4”) on the<br />
ground and place the 8pt Crown in the center of the tent.<br />
Step 2:<br />
Start assembling the frame by inserting and pinning the four hip<br />
rafter poles to the 8pt Crown. Connect the corner fittings to the<br />
bottom of the rafter pipes.<br />
Step 3:<br />
Connect and pin the four (4) rafter pipes to the 8pt crown<br />
Step 4:<br />
Start at one corner of the tent and connect and pin the corner<br />
fitting to the perimeter pipe.<br />
www.aztectents.com
Step 5:<br />
Continue by connecting and pinning the perimeter pipe to this<br />
corner and work your way around the tent connecting all of the<br />
perimeter pipes, side tees, and corner fittings until all of the<br />
upper framing is connected and pinned.<br />
Step 6:<br />
Carefully layout the tent top over the frame and use the buckles<br />
on the underside of the top to attach to the frame. You may<br />
want to lay out a ground cloth at this time to prevent damage<br />
to the tent top when it touches the ground.<br />
**Dragging the top fabric on the ground, or pulling hard over<br />
frame parts can damage, tear, and scratch the fabric. Be careful<br />
with your fabric.<br />
Step 7:<br />
For 1pc Tops skip to step 9. For expandable tops the multiple<br />
sections of the tent top fabric are joined with either a clasp or<br />
lace system and a velcro storm flap. The photo to the right<br />
shows the clasp style connection before the storm flap has<br />
been secured.<br />
Step 8:<br />
The photo to the right shows the lace style connection before<br />
the storm flap has been secured.<br />
www.aztectents.com
Step 9:<br />
Now secure the tent top to the perimeter frame. Tighten the<br />
two buckles closest to the corner fitting first then tighten the<br />
remainder of the buckles.<br />
Step 10:<br />
Lift up one side of the tent off the ground and slide two of the<br />
leg pipes over the corner fitting and pin into place.<br />
Step 11:<br />
Lift up the other side of the tent and install and pin the leg<br />
pipes on the other two corner fittings.<br />
Step 12:<br />
Anchor the tent with the included stakes and ropes. The ropes<br />
should be tied around each of the perimeter fittings with an<br />
overhand slip knot. The stakes should be driven approximately<br />
six (6) feet away from the bottom of the leg. To achieve proper<br />
rope tension, drive each stake approximately 24” into the<br />
ground with a sledge hammer. Tie the rope to the stake with a<br />
clove hitch and continue driving the stake into the ground until<br />
the rope is tight.<br />
www.aztectents.com
<strong>Install</strong>ation- 30’ Wide<br />
Step 1:<br />
Lay out the perimeter pipes, rafter poles, and hip rafter poles<br />
on the ground using the included diagram. Lay out the corner<br />
fittings, special side tee fittings, and crown fitting on the ground.<br />
Step 2:<br />
Connect and pin the four (4) 21’10” hip rafter poles to the 8pt<br />
crown.<br />
Step 3:<br />
Connect and pin the four (4) 16’1” rafter poles to the 8pt crown.<br />
Step 4:<br />
Slide the “30x Slide Hip Fitting” over the hip rafter pole and<br />
slide up to the midpoint of the pole.<br />
www.aztectents.com
Step 5:<br />
Connect and pin the eight (8) 10’6” hip brace pipes to the “30x<br />
Slide hip Fitting”.<br />
Step 6:<br />
Now connect and pin the Special Side Tee fitting to the rafter<br />
pipe and the hip brace pipes<br />
Step 7:<br />
<strong>Install</strong> the 30’ cable across from the special side tee to the<br />
opposite special side tee across the tent. The cable should be<br />
looped over the perimeter arm of the fitting and will keep the<br />
tent from bowing outward past the 30’ width.<br />
Step 8:<br />
Start at one corner of the tent and begin to connect and pin the<br />
perimeter pipes. <strong>Install</strong> the corner fitting on the end of the<br />
21’10” hip rafter and slide on the perimeter pipe. Once both<br />
pipes are on the fitting, line up hole and install the pins.<br />
Continue around the tent connecting and pinning the perimeter<br />
pipes, corner fittings, and special side tee fittings.<br />
www.aztectents.com
Step 9:<br />
Lay down a drop cloth to unfold the tent top on one end of the<br />
tent. Make sure to inspect the tent top for cleanliness at this<br />
time as it becomes next to impossible to clean the exterior of<br />
the tent once the top is installed. Unfold the tent top and pull it<br />
over the frame shiny side up. The buckles should be on the<br />
underside of the tent top.<br />
**Dragging the top fabric on the ground, or pulling hard over<br />
frame parts can damage, tear, and scratch the fabric. Be careful<br />
with your fabric.<br />
Step 10:<br />
For 1pc Tops skip to step 12. For expandable tops the multiple<br />
sections of the tent top fabric are joined with either a clasp or<br />
lace system and a velcro storm flap. The photo to the right<br />
shows the clasp style connection before the storm flap has<br />
been secured.<br />
Step 11:<br />
The photo to the right shows the lace style connection before<br />
the storm flap has been secured.<br />
Step 12:<br />
Now secure the tent top to the perimeter frame. Tighten the<br />
two buckles closest to the corner fitting first then tighten the<br />
remainder of the buckles.<br />
www.aztectents.com
Step 13:<br />
Lift up one side of the tent off the ground and slide two of the<br />
leg pipes over the corner fitting and pin into place. Tent Jacks<br />
(optional accessory) are shown to aid in the lifting of the frame.<br />
Either using tent jacks, man power, or another lifting device the<br />
frame needs to be supported at every leg when lifting to prevent<br />
undue stress on frame members.<br />
Step 14:<br />
Lift up the other side of the tent and install and pin the leg<br />
pipes on the other two corner fittings and middle legs.<br />
Step 15:<br />
Anchor the tent with the included stakes and ropes. The ropes<br />
should be tied around each of the perimeter fittings with an<br />
overhand slip knot. The stakes should be driven approximately<br />
six (6) feet away from the bottom of the leg. To achieve proper<br />
rope tension, drive each stake approximately 24” into the<br />
ground with a sledge hammer. Tie the rope to the stake with a<br />
clove hitch and continue driving the stake into the ground until<br />
the rope is tight.<br />
www.aztectents.com
<strong>Install</strong>ation- 40’ Wide<br />
Step 1:<br />
Layout the perimeter pipes, rafter poles, and hip rafter poles<br />
and brace poles on the ground using the included color diagram.<br />
The entire included framework is color coded by length.<br />
Step 2:<br />
Start building the frame by connecting and pinning the four (4)<br />
21’10” rafter pipes to the 8pt Crown fitting.<br />
Step 3:<br />
Starting from the crown and working down connect and pin the<br />
14’4” hip rafters to the Crown. Now connect and pin the 40x Hip<br />
Intermediate to the bottom end of the upper 14’4” hip rafter.<br />
Continue by connecting and pinning the lower four (4) 14’4” hip<br />
rafter pipes.<br />
Step 4:<br />
Connect and pin the eight (8) 14’4” Braces to the 40x Hip<br />
Intermediate Fitting.<br />
www.aztectents.com
Step 5:<br />
Connect and pin the eight (8) 10’6” Braces to the 40x Hip<br />
Intermediate Fitting.<br />
Step 6:<br />
Start at one corner of the tent and begin to connect and<br />
pin the perimeter pipes. <strong>Install</strong> the corner fitting on the end<br />
of the 14’4” hip rafter and slide on the perimeter pipe.<br />
Once both pipes are on the fitting, line up hole and install<br />
the pins. Continue around the tent connecting and pinning<br />
the perimeter pipes, corner fittings, side tee fittings and<br />
special side tee fittings. <strong>Install</strong> the 40’ cable across from<br />
the special side tee to the opposite special side tee across<br />
the tent. The cable should be looped over the perimeter<br />
arm of the fitting and will keep the tent from bowing outward<br />
past the 40’ width.<br />
Step 7:<br />
Lay down a drop cloth to unfold the tent top on one end of<br />
the tent. Make sure to inspect the tent top for cleanliness at<br />
this time as it becomes next to impossible to clean the<br />
exterior of the tent once the top is installed. Unfold the tent<br />
top and pull it over the frame shiny side up. The buckles<br />
should be on the underside of the tent top.<br />
**Dragging the top fabric on the ground, or pulling hard<br />
over frame parts can damage, tear, and scratch the fabric.<br />
Be careful with your fabric.<br />
Step 8:<br />
For 1pc Tops skip to step 10. For expandable tops the<br />
multiple sections of the tent top fabric are joined with either<br />
a clasp or lace system and a velcro storm flap. The photo<br />
to the right shows the clasp style connection before the<br />
storm flap has been secured.<br />
www.aztectents.com
Step 9:<br />
The photo to the right shows the lace style connection before<br />
the storm flap has been secured.<br />
Step 10:<br />
Now secure the tent top to the perimeter frame. Tighten the<br />
two buckles closest to the corner fitting first then tighten the<br />
remainder of the buckles.<br />
Step 11:<br />
Lift up one side of the tent off the ground and slide two of the<br />
leg pipes over the corner fitting and pin into place. Tent Jacks<br />
(optional accessory) are shown to aid in the lifting of the frame.<br />
Either using tent jacks, man power, or another lifting device the<br />
frame needs to be supported at every leg when lifting to prevent<br />
undue stress on frame members.<br />
Step 12:<br />
Lift up the other side of the tent and install and pin the leg<br />
pipes on the other two corner fittings and middle legs.<br />
www.aztectents.com
Step 13:<br />
Anchor the tent with the included stakes and ropes. The ropes<br />
should be tied around each of the perimeter fittings with an<br />
overhand slip knot. The stakes should be driven approximately<br />
six (6) feet away from the bottom of the leg. To achieve proper<br />
rope tension, drive each stake approximately 24” into the<br />
ground with a sledge hammer. Tie the rope to the stake with a<br />
clove hitch and continue driving the stake into the ground until<br />
the rope is tight<br />
www.aztectents.com
<strong>Install</strong>ation- Qwiktop Option<br />
Step 1:<br />
The Qwiktop <strong>Frame</strong> Tent is installed in a very similar manner as<br />
the standard expandable tops. Build your frame as shown in<br />
the previous instructions. The tent tops themselves do not have<br />
perimeter buckles to secure to the frame, but rather use valance<br />
tensioning to hold the fabric to the frame. Lay down a drop<br />
cloth to unfold the tent top on one end of the tent. Make sure to<br />
inspect the tent top for cleanliness at this time as it becomes<br />
next to impossible to clean the exterior of the tent once the top<br />
is installed. Unfold the tent top and pull it over the frame shiny<br />
side up. The buckles should be on the underside of the tent top.<br />
Step 2:<br />
For 1pc Tops Skip to step 4. For expandable tops the multiple<br />
sections of the tent top fabric are joined with either a clasp or<br />
lace system and a velcro storm flap. The photo to the right<br />
shows the clasp style connection before the storm flap has<br />
been secured.<br />
Step 3:<br />
The photo to the right shows the lace style connection before<br />
the storm flap has been secured.<br />
Step4:<br />
At the corner of the tent top fabric there is a loop that should<br />
be pulled over the nub of the corner fitting prior to installing<br />
the legs.<br />
Step5:<br />
Tension the Qwiktop valance to the baseplates with the included<br />
rope tensioner or ratchet tensioner. Continue to stake the<br />
tent per the standard instructions. The photo to the right shows<br />
the finished Qwiktop installed.<br />
www.aztectents.com
Diagrams<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\10x\10x10.dwg, 2/28/2007 9:59:16 AM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\10x\10x20.dwg, 2/28/2007 10:07:28 AM, <strong>pdf</strong>Factory.pc3
Diagrams- Cont.<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\15x\15x15.dwg, 4/2/2007 5:43:29 PM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com
Diagrams- Cont.<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\20x\20x20.dwg, 2/14/2007 3:45:09 PM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\20x\20x30.dwg, 2/14/2007 3:50:25 PM, <strong>pdf</strong>Factory.pc3
Diagrams- Cont.<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\30x\30x30.dwg, 2/9/2007 9:12:23 AM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\30x\30x40.dwg, 2/14/2007 5:51:58 PM, <strong>pdf</strong>Factory.pc3
Diagrams- Cont.<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\30x\30x60-15.dwg, 3/30/2009 9:37:38 AM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\30x\30x80.dwg, 2/16/2007 1:55:26 PM, <strong>pdf</strong>Factory.pc3
Diagrams- Cont.<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\40x\40x40.dwg, 7/13/2006 3:57:50 PM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\40x\40x60.dwg, 2/16/2007 5:45:38 PM, <strong>pdf</strong>Factory.pc3
Diagrams- Cont.<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\40x\40x80.dwg, 2/22/2007 1:38:56 PM, <strong>pdf</strong>Factory.pc3<br />
www.aztectents.com
www.aztectents.com<br />
K:\cad files\<strong>Frame</strong> Tents\DIAGRAMS\40x\40x100.dwg, 2/22/2007 3:00:26 PM, <strong>pdf</strong>Factory.pc3
Parts Listing<br />
Item<br />
20x <strong>Std</strong>. <strong>Frame</strong> Assembly Cable<br />
30x <strong>Std</strong>. <strong>Frame</strong> Assembly Cable<br />
40x <strong>Std</strong>. <strong>Frame</strong> Assembly Cable<br />
Gable Corner Right<br />
Gable Corner Left<br />
Item No.<br />
Z29900120<br />
Z29900130<br />
Z29900140<br />
Z299F00010<br />
Z299F00015<br />
Weight lbs<br />
8<br />
12<br />
16<br />
6<br />
6<br />
Item<br />
6' 10" - 1" Pipe<br />
7' 4" - 1" Pipe<br />
7' 8" - 1" Pipe<br />
8' 4" - 1" Pipe<br />
9' 4" - 1" Pipe<br />
Item No.<br />
Z299P10610<br />
Z299P10704<br />
Z299P10708<br />
Z299P10804<br />
Z299P10904<br />
Weight lbs<br />
4<br />
4<br />
5<br />
5<br />
6<br />
Gable Crown 3PT<br />
2" Slide Fitting ?Add Leg?<br />
Qwik Corner<br />
3 Way Crown<br />
4 Way Crown<br />
Z299F00020<br />
Z299F00030<br />
Z299F00040<br />
Z299F00050<br />
Z299F00060<br />
5<br />
3<br />
6<br />
5<br />
6<br />
10' 4" - 1" Pipe<br />
10' 6" - 1" Pipe<br />
11' 4" - 1" Pipe<br />
11' 10" - 1" Pipe<br />
14' 4" - 1" Pipe<br />
Z299P11004<br />
Z299P11006<br />
Z299P11104<br />
Z299P11110<br />
Z299P11404<br />
6<br />
6<br />
7<br />
7<br />
9<br />
6 Way Crown<br />
8 Way Crown<br />
Hip Intermediate -40X<br />
Hip Slide Intermediate- 30X<br />
Rafter Slide Intermediate 40X<br />
Z299F00070<br />
Z299F00080<br />
Z299F00090<br />
Z299F00100<br />
Z299F00110<br />
10<br />
12<br />
11<br />
3<br />
3<br />
4' 4" - 2" Pipe<br />
4' 11" - 2" Pipe<br />
5' 4" - 2" Pipe<br />
6' 8" - 2" Pipe<br />
6' 10" - 2" Pipe<br />
Z299P20404<br />
Z299P20411<br />
Z299P20504<br />
Z299P20608<br />
Z299P20610<br />
4<br />
4<br />
5<br />
6<br />
6<br />
Slide Top Tee- 1"<br />
Slide Top Tee- 2"<br />
Special Side Tee<br />
Side Tee<br />
Gable Side Tee Fitting<br />
Z299F00115<br />
Z299F00120<br />
Z299F00130<br />
Z299F00140<br />
Z299F00145<br />
3<br />
3<br />
9<br />
6<br />
6<br />
7' 4" - 2" Pipe<br />
7' 8" - 2" Pipe<br />
8' 4" - 2" Pipe<br />
9' 4" - 2" Pipe<br />
10' 6" - 2" Pipe<br />
Z299P20704<br />
Z299P20708<br />
Z299P20804<br />
Z299P20904<br />
Z299P21006<br />
7<br />
7<br />
8<br />
8<br />
10<br />
Top Tee<br />
Acadapin/Assembly Pin<br />
Jumbo Pin<br />
2' Adjustable Qwik Baseplate<br />
Standard Baseplate<br />
Qwik Footplate<br />
Mid-Span Tensioner<br />
1/2" Polypro x 18' Rope<br />
1" X 42" Double Head Stake<br />
Z299F00150<br />
Z299F00160<br />
Z299F00170<br />
Z299F00180<br />
Z299F00190<br />
Z299F00200<br />
Z299F00210<br />
Z299F00220<br />
Z51100070<br />
6<br />
0.08<br />
0.04<br />
8<br />
4<br />
4<br />
2<br />
3<br />
10<br />
11' 4" - 2" Pipe<br />
11' 10" - 2" Pipe<br />
14' 4" - 2" Pipe<br />
16' 1" - 2" Pipe<br />
21' 10" - 2" Pipe<br />
6' 10" - Jumbo Pipe<br />
7' 8" - Jumbo Pipe<br />
9' 4" - Jumbo Pipe<br />
10' 6" - Jumbo Pipe<br />
11' 4" - Jumbo Pipe<br />
Z299P21104<br />
Z299P21110<br />
Z299P21404<br />
Z299P21601<br />
Z299P22110<br />
Z299PJ0610<br />
Z299PJ0708<br />
Z299PJ0904<br />
Z299PJ1006<br />
Z299PJ1104<br />
11<br />
11<br />
13<br />
15<br />
20<br />
13<br />
14<br />
18<br />
20<br />
21<br />
11' 10" - Jumbo Pipe<br />
13' 4"- Jumbo Pipe<br />
14' 4" - Jumbo Pipe<br />
16' 1" - Jumbo Pipe<br />
19' 4" - Jumbo Pipe<br />
21' 10" - Jumbo Pipe<br />
Z299PJ1110<br />
Z299PJ1304<br />
Z299PJ1404<br />
Z299PJ1601<br />
Z299PJ1904<br />
Z299PJ2110<br />
22<br />
25<br />
27<br />
30<br />
36<br />
41<br />
www.aztectents.com
Parts Images<br />
Qwik Corner Side Tee Special Side Tee 4 Way Crown<br />
3 Way Crown 8 Way Crown 6 Way Crown Top Tee<br />
Slide Top Tee 2” Hip Slide Int. 30x Hip Intermediate 40x Rafter Slide Int. 40x<br />
Gable Crown 4pt Gable Crown 3pt Gable Corner Left Gable Corner Right<br />
Standard Baseplate Qwik Footplate Acadapin Jumbo Pin
If YOU can IMAGINE it... WE can BUILD it<br />
www.aztectents.com<br />
<strong>Aztec</strong> Tents<br />
2665 Columbia Street<br />
Torrance, CA 90503<br />
Toll Free (800) 228-3687<br />
Fax (310) 381-0722