You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Name<br />
Power<br />
source<br />
Ground<br />
Process<br />
switch<br />
Inhibit<br />
Common<br />
Motor<br />
voltage<br />
Low<br />
output<br />
High1<br />
output<br />
High2<br />
output<br />
Symbol<br />
POWER<br />
E<br />
X1<br />
X2<br />
X3<br />
IH<br />
CM<br />
U<br />
V<br />
W<br />
c<br />
a<br />
b<br />
c<br />
a<br />
b<br />
c<br />
a<br />
b<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
IN/<br />
OUT<br />
IN<br />
<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
Pin<br />
No.<br />
6<br />
7<br />
8<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
5<br />
4<br />
3<br />
20<br />
1<br />
2<br />
9<br />
10<br />
11<br />
<br />
<br />
<br />
<br />
<br />
Explanation<br />
Connection of power<br />
source<br />
Ground terminal<br />
Process switch terminal<br />
Inhibit terminal<br />
X1, X2, X3, IH common terminal<br />
Motor voltage input<br />
terminal<br />
Relay contact output<br />
when the lower limit<br />
output is activated<br />
Relay contact output<br />
when the higher limit 1<br />
output is activated<br />
Relay contact output<br />
when the higher limit 2<br />
output is activated<br />
<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
Parameter Data<br />
Data<br />
when<br />
shipment<br />
Contents<br />
Parameter lock<br />
1Unlock<br />
Can change parameter settings<br />
2Lock<br />
1 Can not change parameter settings<br />
unless in an unlocked condition<br />
1Power<br />
Monitor with motor input power<br />
Monitor<br />
1 Monitor with the torque<br />
2Torque<br />
calculated by the power<br />
Motor voltage<br />
1200220V<br />
2400440V<br />
Motor voltage 3 phase 200V class<br />
1<br />
Motor voltage 3 phase 400V class<br />
Motor kW<br />
Motor pole<br />
0.1110kW<br />
2, 4, 6, 8<br />
0.75<br />
4<br />
Setting motor capacity<br />
Number of motor pole<br />
1H2 self-hold<br />
2L self-hold Selection of output<br />
Output relay<br />
3 activation mode<br />
3L, H2 self-hold (upper 2, lower)<br />
4Auto-reset<br />
Start time<br />
Shock time Low<br />
Shock time High1<br />
Shock time High2<br />
Inhibit time<br />
Process<br />
Low level<br />
0.120.0s<br />
MIN,0.110.0s<br />
MIN,0.110.0s<br />
MIN,0.110.0s<br />
IH,0.110.0s<br />
18<br />
99099<br />
3.0<br />
2.0<br />
2.0<br />
2.0<br />
4.0<br />
1<br />
0<br />
Setting the start time<br />
Lower shock time<br />
Higher 1 shock time<br />
Higher 2 shock time<br />
Inhibit time<br />
Number of process<br />
Lower level of process 1<br />
High1 level<br />
High2 level<br />
2005 80<br />
5200<br />
2005 100<br />
5200<br />
Higher 1 level of process 1<br />
Higher 2 level of process 1<br />
Offset<br />
Gain<br />
Sampling data<br />
099<br />
10200<br />
150<br />
0<br />
100<br />
5<br />
Compensation for no-load loss<br />
Display magnification<br />
Number of moving average<br />
Trip test<br />
1YES<br />
Selecton of test mode<br />
1<br />
2NO<br />
during motor operation<br />
<br />
130