Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
No.<br />
Parameter<br />
Data<br />
Data<br />
when<br />
shipment<br />
Contents<br />
Name<br />
Power<br />
source<br />
Ground<br />
Control<br />
input<br />
Motor<br />
voltage<br />
OUT 1<br />
output<br />
OUT 2<br />
output<br />
OUT 3<br />
output<br />
No connection<br />
Symbol<br />
POWER<br />
E<br />
X1<br />
X2<br />
X3<br />
X4<br />
X5<br />
CM<br />
U<br />
V<br />
W<br />
c<br />
a<br />
a<br />
c<br />
a<br />
b<br />
c<br />
<br />
<br />
IN/<br />
OUT<br />
IN<br />
<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
IN<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
N.C.<br />
<br />
<br />
Pin<br />
No.<br />
6<br />
7<br />
8<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
9<br />
10<br />
1<br />
20<br />
4<br />
3<br />
5<br />
2<br />
<br />
<br />
<br />
<br />
<br />
Explanation<br />
Connection of power<br />
source<br />
Ground terminal<br />
Order to start integration<br />
Selection of detection level<br />
Inhibit input<br />
Control input common terminal<br />
Motor voltage input<br />
terminal<br />
Lower limit output after<br />
integration<br />
Higher limit output after<br />
integration<br />
Higher limit output at<br />
instantaneous electric<br />
power<br />
Do not connect anything<br />
1<br />
2a<br />
2b<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
Parameter lock 1Unlock<br />
2Lock<br />
Basic time 0.125s<br />
Integrated time X1,0.125s<br />
Motor voltage 1200220V<br />
2400440V<br />
Motor kW 0.1110kW<br />
Relay<br />
1Self-hold<br />
OUT 3 2Auto reset<br />
Start time 0.120.0s<br />
Shock time OUT 3 MIN,0.110.0s<br />
Inhibit time IH,0.110.0s<br />
Process 18<br />
OUT 1 level 099<br />
OUT 2 level 5200<br />
OUT 3 level 5200<br />
Response 1QUICK<br />
2NORMAL<br />
3SLOW<br />
Can change parameter setting<br />
1<br />
Can not change parameter setting<br />
unless in an unlocked condition<br />
Time setting of rated value of<br />
2.5 integrated power<br />
5.0<br />
Setting of integrated time of<br />
power value<br />
Motor voltage 3 phase<br />
200V class<br />
1<br />
Motor voltage 3 phase<br />
400V class<br />
0.75 Setting motor capacity<br />
Output OUT 3 self-hold<br />
2<br />
Output OUT 3 auto reset<br />
3.0 Setting the start time<br />
2.0 Setting shock time OUT 3<br />
Setting inhibit time<br />
IH (stopping detection time)<br />
Setting the number of<br />
1<br />
detection level selection<br />
Setting integrated power<br />
0 lower limit level<br />
Setting integrated power<br />
80 higher limit level<br />
Setting instantaneous power<br />
100 higher limit level<br />
2 Response for power detection<br />
<br />
134