TSBSD10<br />
TSBSD60<br />
<br />
CT<br />
<br />
<br />
<br />
Function<br />
Model<br />
Load current (set current range) 3<br />
200V class<br />
Motor<br />
400V class<br />
Ambient temperature<br />
Operating<br />
Relative humidity<br />
environment<br />
Vibration<br />
Height<br />
Ambient atmosphere<br />
Current setting accuracy<br />
Start time<br />
Set time range<br />
3<br />
Shock time 3<br />
Power supply voltage (A1-A2)<br />
Maximum motor circuit voltage<br />
Current detecting system<br />
Standard<br />
Main unit parts<br />
Protection functions<br />
(not including overload)<br />
Trip output relay<br />
Relay operation<br />
Reverse phase<br />
Open phase<br />
Phase unbalance<br />
Contact capacity<br />
Minimum application load 2<br />
Operational mode<br />
at time of trip<br />
Non-operational mode<br />
at time of trip<br />
Trip status<br />
Reset method<br />
Set level<br />
Contact capacity<br />
Alarm output relay<br />
Minimum application load 2<br />
Operation<br />
Mechanical<br />
Output relay life<br />
Electrical<br />
Test functions<br />
Between the circuit and case<br />
Withstand voltage Between contacts<br />
Between circuit<br />
Mass<br />
Power consumption<br />
Attachable DIN rail<br />
Normal state<br />
At the time of trip<br />
Normal state<br />
At the time of trip<br />
Self-holding<br />
Automatic reset<br />
TSBSD10<br />
0.510A<br />
0.1 1 2.2kW<br />
0.2 1 3.7kW<br />
TSBSD60<br />
560A<br />
3.711kW<br />
5.522kW<br />
1050<br />
45-85% with no condensation<br />
Less than 5.9m/s 2<br />
Less than 1000m<br />
No corrosive gas or dust<br />
10% (full scale)<br />
0.312.0s<br />
0.33.0s<br />
AC85-250V, 50/60Hz or DC85V-250V<br />
AC600V, 50/60Hz<br />
3 phase CT system<br />
Trips 0.1s after phase reversal detected<br />
Trips 3s after open phase detected<br />
Trips 8s after phase unbalance (maximum value 2x minimum value) current detected<br />
1a1b contact, AC250V 3A (in case of resistance load)<br />
DC24V, 4mA<br />
Relay is not excited (no operation)<br />
Relay is excited (operation)<br />
After start-up there is a 0.5s delay; then relay is excited (operation)<br />
Relay is not excited (no operation)<br />
Self-holding/automatic resetting selectable<br />
RESET button is on or power is off<br />
Resets 1s after tripping<br />
50-100% of set load current value<br />
1a contact, AC250V 3A (in the case of resistance load)<br />
DC24V, 4mA<br />
When the alarm level is exceeded for more than 1s, it will switch from close to flicker or from open to close .<br />
10,000,000 times<br />
100,000 times<br />
Operation check of shock time and output relay<br />
AC2000V, 60Hz, 1 minute (power supply circuits and contact circuits)<br />
AC1000V, 60Hz, 1 minute<br />
AC2000V, 60Hz, 1 minute (power supply circuits and contact circuits)<br />
0.2kg<br />
Less than 4.0VA (less than 3.0W)<br />
Available<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
TSB3CT100<br />
100A<br />
CT External<br />
Reference<br />
Motor<br />
Model<br />
Rated primary current<br />
Rated secondary current<br />
Rated load<br />
Mass<br />
Combined unit model<br />
200V class<br />
400V class<br />
1518.5kW<br />
3045kW<br />
TSB3CT200<br />
200A<br />
5A<br />
5VA<br />
0.9kg<br />
TSBSD10<br />
2237kW<br />
5590kW<br />
<br />
TSB3CT300<br />
300A<br />
4575kW<br />
110132kW<br />
86