Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Name<br />
Power<br />
source<br />
Ground<br />
Count up<br />
output<br />
External<br />
input<br />
Motor<br />
voltage<br />
FWD<br />
STOP<br />
REV<br />
Symbol<br />
POWER<br />
E<br />
c<br />
a<br />
X1<br />
X2<br />
<br />
CM<br />
U<br />
V<br />
W<br />
c<br />
a<br />
c<br />
b<br />
a<br />
c<br />
<br />
<br />
IN/<br />
OUT<br />
IN<br />
<br />
OUT<br />
OUT<br />
IN<br />
IN<br />
N.C.<br />
N.C.<br />
N.C.<br />
IN<br />
IN<br />
IN<br />
IN<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
<br />
<br />
<br />
<br />
Pin<br />
No.<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
1<br />
2<br />
3<br />
4<br />
5<br />
<br />
<br />
<br />
<br />
<br />
<br />
Explanation<br />
Connection of power<br />
source<br />
Ground terminal<br />
Crush error output (1s shot)<br />
Order of automatic operation<br />
(forward rotation)<br />
(Manual) Order of reverse rotation<br />
Do not connect anything<br />
External input common terminal<br />
Motor voltage input<br />
terminal<br />
Order of forward rotation<br />
Order of stop (1s shot)<br />
Order of reverse rotation<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
Parameter lock 1Unlock<br />
2Lock<br />
Motor voltage 1200220V<br />
2400440V<br />
Motor kW 0.1110kW<br />
0.1200kW<br />
No load level Unused<br />
5200<br />
Overload level 5200<br />
Start time 1300s<br />
No load 0.160min<br />
continuing<br />
level<br />
Shock time MIN,0.110.0s<br />
Pause time<br />
1<br />
Parameter<br />
Data<br />
1600s<br />
10<br />
11<br />
Reverse time<br />
Pause time<br />
2<br />
1600s<br />
1600s<br />
12<br />
13<br />
No. of reverse rotation<br />
Reverse<br />
rotation<br />
110 times<br />
Plus<br />
count time 1600s<br />
14 Response 1QUICK<br />
2NORMAL<br />
3SLOW<br />
Data<br />
when<br />
Contents<br />
shipment<br />
Can change parameter setting<br />
1<br />
Can not change parameter setting<br />
unless in an unlocked condition<br />
Motor voltage 3 phase<br />
1<br />
200V class<br />
Motor voltage 3 phase<br />
400V class<br />
Setting 200V class motor<br />
capacity<br />
0.75<br />
Setting 400V class motor<br />
capacity<br />
Unused<br />
1.0<br />
10<br />
5<br />
10<br />
5<br />
100<br />
Prevention of idle running<br />
100 Overload detection level<br />
5 Setting the start time<br />
Time between after underrunning<br />
no load level until<br />
15<br />
COUNTUP output<br />
Shock time when overload<br />
occurs<br />
Pause time during switching<br />
from forward to reverse<br />
rotation<br />
Reverse running time<br />
Pause time during switching<br />
from reverse to forward<br />
rotation<br />
No. of reverse rotation until<br />
COUNTUP output<br />
Time to count the no. of<br />
reverse rotation.<br />
Add to 1 cycle time<br />
2 Response for power detection<br />
135