You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
No.<br />
1<br />
2<br />
Parameter<br />
Motor voltage<br />
Motor kW<br />
Data<br />
1200220V<br />
2400440V<br />
0.1110kW<br />
Data<br />
when<br />
shipment<br />
1<br />
0.75<br />
Contents<br />
Motor voltage 3 phase<br />
200V class<br />
Motor voltage 3 phase<br />
400V class<br />
Setting motor capacity<br />
Name<br />
Power<br />
source<br />
Ground<br />
Control<br />
input<br />
Motor<br />
voltage<br />
HIGH 1<br />
output<br />
HIGH 2<br />
output<br />
No<br />
connection<br />
Symbol<br />
POWER<br />
E<br />
X1<br />
RES<br />
X2<br />
<br />
CM<br />
U<br />
V<br />
W<br />
a<br />
b<br />
c<br />
a<br />
b<br />
c<br />
<br />
IN/<br />
OUT<br />
IN<br />
IN<br />
IN<br />
N.C.<br />
N.C.<br />
IN<br />
IN<br />
IN<br />
IN<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
OUT<br />
N.C.<br />
N.C.<br />
N.C.<br />
Pin<br />
No.<br />
6<br />
7<br />
8<br />
12<br />
14<br />
13<br />
15<br />
16<br />
17<br />
18<br />
19<br />
1<br />
2<br />
20<br />
4<br />
3<br />
20<br />
9<br />
10<br />
11<br />
Explanation<br />
Connection of power<br />
source<br />
Ground terminal<br />
Rewriting setting level<br />
Reset terminal<br />
Do not connect anything<br />
Control input common<br />
Motor voltage input<br />
terminal<br />
Relative value higher limit<br />
output 1<br />
Absolute value higher limit<br />
output 2<br />
Do not connect anything<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
Relay<br />
1Self-hold<br />
HIGH1 2Auto reset<br />
Relay<br />
1Self-hold<br />
HIGH2 2Auto reset<br />
Start time 0.120.0s<br />
Shock time HIGH 1 MIN,0.110.0s<br />
Shock time HIGH 2 MIN,0.110.0s<br />
HIGH 1level<br />
199<br />
HIGH 2level<br />
5200<br />
Response 1QUICK<br />
2NORMAL<br />
3SLOW<br />
Basic writing 1Interval<br />
2X1<br />
Interval time 160s<br />
1.160.0min<br />
HIGH 1 output relay self-hold<br />
2<br />
HIGH 1 output relay auto reset<br />
HIGH 2 output relay self-hold<br />
2<br />
HIGH 2 output relay auto reset<br />
3.0 Setting the start time<br />
2.0 Setting HIGH 1 shock time<br />
2.0 Setting HIGH 2 shock time<br />
Setting HIGH 1 level<br />
10 (after rewriting setting level,<br />
relative value)<br />
Setting HIGH 2 level<br />
100 (is not influenced by rewriting<br />
setting level, absolute value)<br />
2 Response for power detection<br />
2<br />
50s<br />
Writing when the start time ends,<br />
or each interval<br />
Writing when the start time ends,<br />
or X1 is input<br />
Writing cycle<br />
<br />
132