MEDALLION-LOK<br />
HIGH SIDE TIE-IN - SIDEWALL PARAPET ABOVE ROOFLINE<br />
Sealant (Not by <strong>McElroy</strong>)<br />
Counter Flashing<br />
(Not by <strong>McElroy</strong>)<br />
Parapet Wall<br />
Fastener (Not<br />
by <strong>McElroy</strong>)<br />
43D Pop Rivet<br />
at 0’ - 6” O.C.<br />
Tie-In Trim<br />
Zee Closure (Field Cut)<br />
w/1” Roll Tape Sealant<br />
Top and Bottom<br />
<strong>Medallion</strong>-<strong>Lok</strong> Panel<br />
6” Max.<br />
Butyl Tube Sealant<br />
<strong>Medallion</strong>-<strong>Lok</strong> Clip<br />
Min. #30 Felt Paper<br />
(Recommended)<br />
Pancake Head Fastener<br />
#10 - 12 x 1” Type A<br />
Substructure<br />
Hex Head Fastener<br />
#9 - 15 x 1” Type A Woodgrip<br />
2 Required per Panel<br />
(Must Penetrate Tape Sealant)<br />
Counter Flashing<br />
(Not by <strong>McElroy</strong>)<br />
Sealant (Not by <strong>McElroy</strong>)<br />
Parapet Wall<br />
Tie-In Trim<br />
<strong>Medallion</strong>-<strong>Lok</strong><br />
Panel<br />
Zee Closure<br />
w/1” Roll<br />
Tape Sealant<br />
(Top and<br />
Bottom)<br />
Min. #30 Felt Paper (Recommended)<br />
Substructure<br />
NOTES:<br />
1. After panels are installed, place a continuous run of 1” roll tape sealant approximately 6” from<br />
edge of wall subtructure.<br />
2. Field cut zee closure and install over tape sealant and attach with two (2) #9 - 15 x 1”<br />
fasteners through closure, sealant, panel and into substructure. Locate as shown.<br />
3. Apply tube sealant to zee closure and panel ribs.<br />
4. Apply a continuous run of 1” roll tape sealant over zee closure and fasten trim to closure with<br />
43D pop rivets on 6" centers. Use tube sealant at closure.<br />
5. Fasteners for attachment to parapet wall is not by <strong>McElroy</strong> <strong>Metal</strong>.<br />
6. Counter flashing and sealant to parapet wall are not by <strong>McElroy</strong> <strong>Metal</strong>.<br />