Caution: If joint is over-assembled causing the spigot to jam into the neck<br />

of the bell, flexibility of the joint is lost. Uneven settlement of the trench or<br />

additional loading may cause this type of joint assembly to leak or crack.<br />

Do not assemble beyond the reference mark.<br />

Figure 10<br />

If undue resistance to insertion of the beveled end is encountered or the<br />

reference mark does not reach the flush position, disassemble the joint and<br />

check the position of the gasket. If it is twisted or pushed out of its seat, do<br />

not attempt to realign gasket, replace with another piece of pipe. Be sure<br />

both lengths are in proper alignment.<br />

NOTICE: Should a spigot or bell end become deformed under load at higher<br />

temperatures, it will be necessary to exercise more care in assembling the<br />

joint in order to prevent fish-mouthing of the gasket.<br />

6. No deflection at joint is allowed on 12 inches and smaller pipe. Pipe<br />

curvature should be accomplished by bending the pipe rather than<br />

deflecting the joints as noted in Section 2.2.<br />

NOTICE: If a pry-bar or backhoe is used for any assembly, a wood plank<br />

should be placed between the pipe and the machine to prevent damage. In<br />

addition, the force applied must be steady and constant. Do not ram or hit<br />

the pipe. For all pipe, a come-a-long jack is recommended over a backhoe.<br />

The method of attachment to the pipe must not abrade or damage the pipe<br />

in any way. Steps must be taken during installation using these methods to<br />

maintain correct alignment of the pipe. In addition, a helper should be present<br />

in all cases to assist the operator in knowing when the reference mark is<br />

reached properly.<br />

22 IRRIGATION & I.P.S. PRESSURE INSTALLATION GUIDE