Caution: If joint is over-assembled causing the spigot to jam into the neck<br />
of the bell, flexibility of the joint is lost. Uneven settlement of the trench or<br />
additional loading may cause this type of joint assembly to leak or crack.<br />
Do not assemble beyond the reference mark.<br />
Figure 10<br />
If undue resistance to insertion of the beveled end is encountered or the<br />
reference mark does not reach the flush position, disassemble the joint and<br />
check the position of the gasket. If it is twisted or pushed out of its seat, do<br />
not attempt to realign gasket, replace with another piece of pipe. Be sure<br />
both lengths are in proper alignment.<br />
NOTICE: Should a spigot or bell end become deformed under load at higher<br />
temperatures, it will be necessary to exercise more care in assembling the<br />
joint in order to prevent fish-mouthing of the gasket.<br />
6. No deflection at joint is allowed on 12 inches and smaller pipe. Pipe<br />
curvature should be accomplished by bending the pipe rather than<br />
deflecting the joints as noted in Section 2.2.<br />
NOTICE: If a pry-bar or backhoe is used for any assembly, a wood plank<br />
should be placed between the pipe and the machine to prevent damage. In<br />
addition, the force applied must be steady and constant. Do not ram or hit<br />
the pipe. For all pipe, a come-a-long jack is recommended over a backhoe.<br />
The method of attachment to the pipe must not abrade or damage the pipe<br />
in any way. Steps must be taken during installation using these methods to<br />
maintain correct alignment of the pipe. In addition, a helper should be present<br />
in all cases to assist the operator in knowing when the reference mark is<br />
reached properly.<br />
22 IRRIGATION & I.P.S. PRESSURE INSTALLATION GUIDE