2.2 Basic Definitions<br />
2.2 Basic Definitions<br />
Letter Coding<br />
I = Feed rate<br />
Material amount discharged from belt per unit of time (kg/h)<br />
V = Speed of conveyor belt (m/s)<br />
Q = Belt load<br />
Material weight on one belt meter (kg/m)<br />
Measuring Principles<br />
Belt load (Q) <strong>and</strong> speed (V) are continuously measured <strong>and</strong> factored<br />
together. The result is feed rate (I) from which the flowrate is<br />
determined.<br />
I = Q x V x 3600<br />
<strong>INTECONT</strong> <strong>Satus</strong> <strong>Commissioning</strong> <strong>and</strong> <strong>Set</strong>-<strong>Up</strong> BV-H5123GB / 0852 4<br />
SCHENCK AccuRate