Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Drainage<br />
Easi-Slide Handling Instructions<br />
P12<br />
Easi-slide Lifting Chains<br />
A<br />
B<br />
C<br />
Nominal size 1800 2100 2400<br />
Medium Duty Chain Set 3 3 X<br />
Heavy Duty Chain Set X X 3*<br />
*Only suitable for Lifting not Jointing<br />
Ensure the tension is even.<br />
Do not use Lubricants when jointing Easi-Slide Pipes<br />
Ensure each pipe to be laid is aligned with the laid<br />
pipeline and is fully supported along its length.<br />
Recommended method of joining pipes is shown below.<br />
A<br />
B<br />
C<br />
12<br />
Handling/Lifting Instructions<br />
Pipe Diameters DN1800 to DN2400 are designed and<br />
manufactured to incorporate Easi-Lift jointing and<br />
lifting system.<br />
Easi-Lift System<br />
A<br />
The Lift<br />
To lift the pipes, select the two short legs A and B on<br />
the chain set. Place the spherical coupling over the cast<br />
in anchor and engage by turning the tail of the head<br />
link down to the concrete. The pipe can then be lifted<br />
as normal.<br />
Never pass slings or other lifting appliances through<br />
the barrel and never lift more than one pipe at a time.<br />
Jointing<br />
C<br />
B<br />
Ensure that the seal is of the correct size, and is not<br />
damaged.<br />
Ensure pipe sockets and spigots are not damaged.<br />
Position the rubber ring on the end of the spigot end.<br />
www.fpmccann.co.uk<br />
Easi-Lift joint<br />
To joint the pipe using the chain system. Attach the long<br />
leg C to the already laid pipe and the short leg B to the<br />
pipe to be laid. Take up the slack in the chains with the<br />
lifting pulley over the anchor of the laid pipe, and increase<br />
the upward force to joint the pipes. When jointed, ensure<br />
that there is no excessive slew or misalignment, this can<br />
easily be checked by reference to the joint gap.<br />
Joint Gap<br />
Notes:<br />
1. All dimensions are in mm.<br />
2. Weights in kg are based on a concrete density of<br />
2500kg/m³.<br />
3. Where relevant pipes are manufactured in<br />
accordance with BS EN 1916.<br />
4. Note right hand or left hand junctions (viewed<br />
socket to spigot) should be specified when<br />
ordering reduced junctions in pipe diameters<br />
DN1800 and above.<br />
5. Note lifting chains are not suitable for joining<br />
purposes in pipes of diameter DN2400. Joint in the<br />
traditional method.<br />
6. All junctions to be installed on their side only.<br />
precast@fpmccann.co.uk<br />
WARNING<br />
When Lifting ≥45°<br />
Inclined pull only