Infrastructure & Power<br />
Lid Table 1: All sizes<br />
Power Infrastructure Cable<br />
Ducting Systems<br />
P53<br />
Reference<br />
(width x depth x<br />
length)<br />
(width = span width)<br />
Reference<br />
(width x depth x<br />
length)<br />
(width = span width)<br />
Lid Coding<br />
Description<br />
Loading<br />
group<br />
Class<br />
to BS EN<br />
124<br />
s/w*<br />
nominal<br />
kg<br />
Lid Dimensions (mm)<br />
A B C<br />
1000 x 50 x 1000<br />
1000 GRP Open<br />
Open GRP “Dura Tread” Lid to fit 1000 wide trough with 50 deep rebate 1.5T<br />
ML 1000 50 ODT A<br />
Pedestrian Lid<br />
SWL<br />
A 28.6 1224 1214 50<br />
1000 x 50 x 1000<br />
1000 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 1000 wide trough with 50 deep rebate 1.5T<br />
ML 1000 50 CDS A<br />
Pedestrian Lid<br />
SWL<br />
A 35.7 1224 1214 50<br />
1000 x 50 x 475<br />
1000 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 1000 wide trough with 50 deep rebate 5T<br />
ML 1000 50 CDS B<br />
5T Lid<br />
SWL<br />
B 21.1 1224 1214 50<br />
1000 x 100 x 600<br />
1000 GRP Closed ML 1000 100 CDS Closed GRP “Dura Slab” Lid to fit 1000 wide trough with 100 deep rebate<br />
11.5T Lid<br />
CD<br />
11.5T SWL<br />
C and D 67.1 1224 1204 100<br />
1000 x 100 x 500<br />
1000 5T Concrete<br />
Reinforced concrete Lid to fit 1000 wide trough with 100 deep rebate 5T<br />
ML 1000 100 RC AB<br />
Lid<br />
SWL<br />
A and B 151.1 1224 1204 100<br />
750 x 50 x 1000<br />
750 GRP Open<br />
Open GRP “Dura Tread” Lid to fit 750 wide trough with 50 deep rebate 1.5T<br />
ML 750 50 ODT A<br />
Pedestrian Lid<br />
SWL<br />
A 22.2 949 939 50<br />
750 x 50 x 1000<br />
750 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 750 wide trough with 50 deep rebate 1.5T<br />
ML 750 50 CDS A<br />
Pedestrian Lid<br />
SWL<br />
A 27.6 949 939 50<br />
750 x 50 x 475<br />
750 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 750 wide trough with 50 deep rebate 5T<br />
ML 750 50 CDS B<br />
5T Lid<br />
SWL<br />
B 16.3 949 939 50<br />
750 x 100 x 600<br />
750 GRP Closed ML 750 100 CDS Closed GRP “Dura Slab” Lid to fit 750 wide trough with 100 deep rebate<br />
11.5T Lid<br />
CD<br />
11.5T SWL<br />
C and D 51.9 949 929 100<br />
750 x 100 x 500<br />
750 5T Concrete<br />
Lid<br />
ML 750 100 RC AB Reinforced concrete Lid to fit 750 wide trough with 100 deep rebate 5T SWL A and B 116.9 949 929 100<br />
600 x 50 x 1000<br />
600 GRP Open<br />
Open GRP “Dura Tread” Lid to fit 600 wide trough with 50 deep rebate 1.5T<br />
ML 750 50 ODT A<br />
Pedestrian Lid<br />
SWL<br />
A 17.4 744 724 50<br />
600 x 50 x 1000<br />
600 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 600 wide trough with 50 deep rebate 1.5T<br />
ML 750 50 CDS A<br />
Pedestrian Lid<br />
SWL<br />
A 21.6 744 724 50<br />
600 x 50 x 475<br />
600 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 600 wide trough with 50 deep rebate 5T<br />
ML 750 50 CDS B<br />
5T Lid<br />
SWL<br />
B 12.8 744 724 50<br />
600 x 100 x 600<br />
600 GRP Closed ML 750 100 CDS Closed GRP “Dura Slab” Lid to fit 600 wide trough with 100 deep rebate<br />
11.5T Lid<br />
CD<br />
11.5T SWL<br />
C and D 40.6 744 724 100<br />
600 x 100 x 500<br />
600 5T Concrete<br />
Lid<br />
ML 750 100 RC AB Reinforced concrete Lid to fit 600 wide trough with 100 deep rebate 5T SWL A and B 91.4 744 724 100<br />
350 x 50 x 1000<br />
350 GRP Open<br />
Open GRP “Dura Tread” Lid to fit 350 wide trough with 50 deep rebate 1.5T<br />
ML 350 50 ODT A<br />
Pedestrian Lid<br />
SWL<br />
A 11.7 504 494 50<br />
350 x 50 x 1000<br />
350 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 350 wide trough with 50 deep rebate 1.5T<br />
ML 350 50 CDS A<br />
Pedestrian Lid<br />
SWL<br />
A 14.6 504 494 50<br />
350 x 50 x 475<br />
350 GRP Closed<br />
Closed GRP “Dura Slab” Lid to fit 350 wide trough with 50 deep rebate 5T<br />
ML 350 50 CDS B<br />
5T Lid<br />
SWL<br />
B 8.6 504 494 50<br />
350 x 100 x 600<br />
350 GRP Closed ML 350 100 CDS Closed GRP “Dura Slab” Lid to fit 350 wide trough with 100 deep rebate<br />
11.5T Lid<br />
CD<br />
11.5T SWL<br />
C and D 27.3 504 484 100<br />
350 x 100 x 500<br />
350 5T Concrete<br />
Lid<br />
ML 350 100 RC AB Reinforced concrete Lid to fit 350 wide trough with 100 deep rebate 5T SWL A and B 61.5 504 484 100<br />
* maximum self weight = nominal self + 5%, which should be used to size lifting equipment<br />
53<br />