07.05.2015 Views

Open FX Renewal Guide Pdf - Automation Systems and Controls

Open FX Renewal Guide Pdf - Automation Systems and Controls

Open FX Renewal Guide Pdf - Automation Systems and Controls

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Repair Period<br />

Ended<br />

Repair Period<br />

Ended<br />

June, 2009<br />

<strong>Renewal</strong> method for each model<br />

Repair Period<br />

Ended<br />

June, 2009<br />

Repair Period<br />

Ends January,<br />

2013<br />

<strong>FX</strong>0,<strong>FX</strong>0N,<strong>FX</strong>0S Series PLC renewal<br />

The following steps will guide you through the renewal process for <strong>FX</strong>0, <strong>FX</strong>0N, <strong>and</strong> <strong>FX</strong>0S PLCs:<br />

1. Connect the <strong>FX</strong>0, <strong>FX</strong>0N, <strong>FX</strong>0S PLC to a PC using the <strong>FX</strong>-USB-AW<br />

2. Upload the program with GX Developer <strong>and</strong> change the PLC type.<br />

3. Connect the new <strong>FX</strong> PLC, revise the program, <strong>and</strong> write it to the PLC<br />

Note: As the external dimensions <strong>and</strong> terminal alignment is approximately the same between PLCs, the wiring <strong>and</strong> system<br />

installation will have minimal required changes. additional changes. It is always necessary to confirm that PLC is wired <strong>and</strong><br />

installed correctly, however.<br />

Connect to the <strong>FX</strong>0, <strong>FX</strong>0N, <strong>FX</strong>0S PLC<br />

<br />

<br />

RS-422/USB Interface Converter<br />

<strong>FX</strong>-USB-AW<br />

RS-422/USB Interface Converter<br />

<strong>FX</strong>-USB-AW<br />

O R<br />

<br />

<br />

<strong>FX</strong>0, <strong>FX</strong>0S, <strong>FX</strong>0N series PLC<br />

<strong>FX</strong>0, <strong>FX</strong>0S, <strong>FX</strong>0N series PLC<br />

RS-422 Cable<br />

<strong>FX</strong>-422CAB0<br />

RS-422 Cable<br />

<strong>FX</strong>-422CAB0<br />

<br />

O R<br />

<strong>FX</strong>-232AWC-H<br />

<strong>FX</strong>-232AWC-H<br />

RS-232C Cable<br />

F2-232-CAB-1<br />

RS-232C Cable<br />

F2-232-CAB-1<br />

<br />

RS-232C/RS-422 Interface Converter <br />

<strong>FX</strong>-232AWC-H<br />

RS-232C/RS-422 Interface Converter<br />

<strong>FX</strong>-232AWC-H<br />

Programming Software<br />

- GX Developer(SW[ ]D5C-GPPW)<br />

Programming Software<br />

- GX Developer(SW[ ]D5C-GPPW)<br />

100<br />

100<br />

60 90<br />

60 90<br />

90<br />

80<br />

90<br />

90<br />

<strong>FX</strong>0 (14M) <strong>FX</strong>1S (14M) <strong>FX</strong>3G (14M)<br />

<strong>FX</strong>0 (14M) <strong>FX</strong>1S (14M) <strong>FX</strong>3G (14M)<br />

130<br />

90<br />

90<br />

90<br />

80<br />

90<br />

90<br />

130<br />

90<br />

90<br />

<strong>FX</strong>0N (24M)<br />

<strong>FX</strong>0N (24M)<br />

<strong>FX</strong>3G (24M)<br />

<strong>FX</strong>3G (24M)<br />

Note:<br />

Please refer to the [<strong>FX</strong> Replacement <strong>Guide</strong>] for further details on upgrading <strong>FX</strong> PLCs.<br />

10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!