Section F â Air Atomizing Spray Nozzles - Spraying Systems Co.
Section F â Air Atomizing Spray Nozzles - Spraying Systems Co.
Section F â Air Atomizing Spray Nozzles - Spraying Systems Co.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Pressure <strong>Spray</strong> Set-ups, External Mix,<br />
High Transfer Efficiency (HTE), 1/4J Series<br />
Features and Benefits<br />
C<br />
B<br />
A<br />
• A new air cap design enables the use of lower air pressures to achieve<br />
the same spray performance as conventional external mix set-ups.<br />
Flat spray<br />
pattern<br />
• HTE set-ups operate at pressures as low as 5 psi (0.3 bar).<br />
• A large air chamber directly feeds the air exit orifices. Design provides<br />
high liquid transfer efficiency, minimal air loss, and minimal misting.<br />
• <strong>Air</strong> consumption is reduced and maximum spray coverage on the target<br />
is achieved.<br />
• See also<br />
– <strong>Section</strong> G, Automatic <strong>Spray</strong> <strong>Nozzles</strong><br />
<strong>Air</strong> Ca p s<br />
D<br />
Round spray<br />
pattern<br />
D<br />
C<br />
B<br />
A<br />
6" (15 cm)<br />
9" (23 cm)<br />
15" (38 cm)<br />
6" (15 cm)<br />
9" (23 cm)<br />
15" (38 cm)<br />
1158 retainer ring and 3612 gasket must be ordered separately<br />
from the spray set-up, but are included in the standard nozzle<br />
assembly. Please contact your sales engineer.<br />
HTE air cap produces a flat<br />
spray and a round spray.<br />
Performance Data<br />
<strong>Air</strong> <strong>Atomizing</strong><br />
<strong>Nozzles</strong><br />
Flat <strong>Spray</strong> (External Mix)<br />
<strong>Spray</strong><br />
Set-up<br />
No.<br />
SU-HTE60D<br />
SU-HTE60E<br />
SU-HTE60F<br />
<strong>Spray</strong><br />
Set-up<br />
<strong>Co</strong>nsists of<br />
Fluid and<br />
<strong>Air</strong> Cap<br />
<strong>Co</strong>mbination<br />
Fluid Cap<br />
PF28100<br />
+<br />
<strong>Air</strong> Cap<br />
LP130262-60<br />
Fluid Cap<br />
PF20100<br />
+<br />
<strong>Air</strong> Cap<br />
LP130262-60<br />
Fluid Cap<br />
PF16100<br />
+<br />
<strong>Air</strong> Cap<br />
LP130262-60<br />
<strong>Air</strong><br />
Press.<br />
*At the stated pressure in bar.<br />
Liquid Capacity (liters per hour)* and <strong>Air</strong> Capacity (liters per minute)*<br />
Liquid Pressure<br />
0.3 0.7 1 1.4 2.1<br />
l/h<br />
<strong>Air</strong><br />
l/min<br />
<strong>Air</strong><br />
Press.<br />
l/h<br />
<strong>Air</strong><br />
l/min<br />
<strong>Air</strong><br />
Press.<br />
l/h<br />
<strong>Air</strong><br />
l/min<br />
<strong>Air</strong><br />
Press.<br />
l/h<br />
<strong>Air</strong><br />
l/min<br />
<strong>Air</strong><br />
Press.<br />
l/h<br />
<strong>Air</strong><br />
l/min<br />
.55 11.4 94 .55 15.9 94 – – – – – – – – –<br />
.69 11.4 106 .69 15.9 106 .69 19.3 106 – – – – – –<br />
.83 11.4 118 .83 15.9 118 .83 19.3 118 .83 23 118 – – –<br />
.97 11.4 129 .97 15.9 129 .97 19.3 129 .97 23 129 .97 27 129<br />
1.1 11.4 139 1.1 15.9 139 1.1 19.3 139 1.1 23 139 1.1 27 139<br />
.41 6.1 81 .41 8.3 81 – – – – – – – – –<br />
.55 6.1 94 .55 8.3 94 .55 9.8 94 – – – – – –<br />
.69 6.1 106 .69 8.3 106 .69 9.8 106 .69 11.7 106 – – –<br />
.83 6.1 118 .83 8.3 118 .83 9.8 118 .83 11.7 118 – – –<br />
.97 6.1 129 .97 8.3 129 .97 9.8 129 .97 11.7 129 .97 14.0 129<br />
1.1 6.1 139 1.1 8.3 139 1.1 9.8 139 1.1 11.7 139 1.1 14.0 139<br />
.28 3.8 65 – – – – – – – – – – – –<br />
.41 3.8 81 – – – – – – – – – – – –<br />
.55 3.8 94 .55 5.3 94 .55 6.4 94 .55 7.6 94 – – –<br />
.69 3.8 106 .69 5.3 106 .69 6.4 106 .69 7.6 106 – – –<br />
.83 3.8 118 .83 5.3 118 .83 6.4 118 .83 7.6 118 .83 9.1 118<br />
.97 3.8 129 .97 5.3 129 .97 6.4 129 .97 7.6 129 .97 9.1 129<br />
1.1 3.8 139 1.1 5.3 139 1.1 6.4 139 1.1 7.6 139 1.1 9.1 139<br />
Add DF to part number for “Drip Free” set-ups. Example: SU-HTE60D-DF.<br />
The operating pressures and flow rates are based on spraying water and air at room temperature.<br />
Adjustments may need to be made to accommodate other liquids with different characteristics.<br />
<strong>Air</strong>* Liquid*<br />
.69<br />
1.0<br />
.69<br />
1.0<br />
.69<br />
.34<br />
.69<br />
1.0<br />
.34<br />
.69<br />
1.0<br />
.21<br />
.34<br />
.69<br />
1.0<br />
.34<br />
.69<br />
1.0<br />
.34<br />
.34<br />
.69<br />
.69<br />
1.4<br />
.34<br />
.34<br />
.34<br />
.69<br />
.69<br />
.69<br />
.34<br />
.34<br />
.34<br />
.34<br />
.69<br />
.69<br />
.69<br />
<strong>Spray</strong><br />
Dimensions<br />
A<br />
(cm)<br />
18<br />
13<br />
29<br />
15<br />
25<br />
18<br />
10<br />
8<br />
20<br />
17<br />
17<br />
24<br />
23<br />
20<br />
17<br />
22<br />
19<br />
15<br />
B<br />
(cm)<br />
33<br />
15<br />
34<br />
23<br />
38<br />
23<br />
11<br />
11<br />
28<br />
18<br />
18<br />
28<br />
25<br />
23<br />
19<br />
24<br />
23<br />
19<br />
C<br />
(cm)<br />
36<br />
20<br />
36<br />
25<br />
43<br />
16<br />
11<br />
14<br />
33<br />
18<br />
19<br />
33<br />
30<br />
29<br />
22<br />
30<br />
28<br />
24<br />
D<br />
(cm)<br />
91<br />
102<br />
102<br />
114<br />
104<br />
64<br />
79<br />
86<br />
56<br />
69<br />
81<br />
58<br />
61<br />
64<br />
71<br />
56<br />
64<br />
74<br />
Phone 1(630) 665-5000, FAX 1(630) 260-0842<br />
Visit Our Web Site: www.spray.com, Email: info@spray.com<br />
F19