15.05.2015 Views

Section F – Air Atomizing Spray Nozzles - Spraying Systems Co.

Section F – Air Atomizing Spray Nozzles - Spraying Systems Co.

Section F – Air Atomizing Spray Nozzles - Spraying Systems Co.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Pressure <strong>Spray</strong> and Siphon/Gravity-Fed<br />

<strong>Spray</strong> Set-ups, External Mix, 1J Series<br />

<strong>Air</strong> Caps<br />

Flat spray and round<br />

spray air caps produce a<br />

flat spray pattern and the<br />

siphon air caps produce a<br />

round spray pattern.<br />

Features and Benefits<br />

• For flat spray, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle.<br />

– The total distance of spray projection from the nozzle to the maximum dispersal point is<br />

represented by “D”.<br />

– When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure.<br />

– The liquid and compressed air or gas are mixed externally to produce a completely atomized spray.<br />

• For round spray, dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle.<br />

– The total distance of spray projection from the nozzle to the maximum dispersal point is<br />

represented by “D”.<br />

– When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or<br />

a gravity-feed.<br />

– Designed to draw liquid through the feed line into the air flow where it is atomized.<br />

C<br />

B<br />

A<br />

<strong>Air</strong> cap<br />

Fluid cap<br />

Performance Data<br />

D<br />

Flat spray<br />

pattern<br />

12"<br />

(30 cm)<br />

30" (76 cm)<br />

48" (122 cm)<br />

12415 retainer ring<br />

12415 retainer ring must be ordered separately from the spray set-up, but is included<br />

in the standard nozzle assembly. Please contact your sales engineer.<br />

<strong>Air</strong> <strong>Atomizing</strong><br />

<strong>Nozzles</strong><br />

Flat <strong>Spray</strong> (External Mix)<br />

<strong>Spray</strong><br />

Set-up<br />

No.<br />

SUE175B<br />

<strong>Spray</strong><br />

Set-up<br />

<strong>Co</strong>nsists of<br />

Fluid and<br />

<strong>Air</strong> Cap<br />

<strong>Co</strong>mbination<br />

Fluid Cap<br />

625780<br />

+<br />

<strong>Air</strong> Cap<br />

12116<br />

<strong>Spray</strong><br />

Pattern<br />

Flat<br />

<strong>Air</strong><br />

l/min<br />

Press.<br />

*At the stated pressure in bar.<br />

Liquid Capacity (liters per minute)* and <strong>Air</strong> Capacity (liters per minute)*<br />

Liquid Pressure<br />

0.2 0.3 0.5 0.7 1<br />

<strong>Air</strong><br />

l/min<br />

<strong>Air</strong><br />

l/min<br />

Press.<br />

Siphon Set-ups Round <strong>Spray</strong><br />

<strong>Spray</strong><br />

Set-up<br />

No.<br />

SU170<br />

<strong>Spray</strong><br />

Set-up<br />

<strong>Co</strong>nsists of<br />

Fluid and<br />

<strong>Air</strong> Cap<br />

<strong>Co</strong>mbination<br />

Fluid Cap<br />

6251000<br />

+<br />

<strong>Air</strong> Cap<br />

1125<br />

<strong>Air</strong><br />

l/min<br />

<strong>Air</strong><br />

l/min<br />

Press.<br />

<strong>Air</strong><br />

l/min<br />

<strong>Air</strong><br />

l/min<br />

Press.<br />

<strong>Air</strong><br />

l/min<br />

<strong>Air</strong><br />

l/min<br />

Press.<br />

<strong>Air</strong><br />

l/min<br />

1.4 49 2460 1.8 59 2860 2.1 76 3260 2.8 90 3960 3.5 107 4700<br />

1.8 49 2860 2.1 59 3260 2.8 76 3960 3.5 90 4700 4.2 107 5410<br />

2.1 49 3260 2.8 59 3960 3.5 76 4700 4.2 90 5410 4.9 107 6120<br />

2.8 49 3960 3.5 59 4700 4.2 76 5410 4.9 90 6120 5.6 107 6850<br />

3.5 49 4700 4.2 59 5410 4.9 76 6120 5.6 90 6850 6.3 107 7590<br />

4.2 49 5410 4.8 59 6120 5.6 76 6850 6.3 90 7590 – – –<br />

<strong>Air</strong><br />

Press.<br />

<strong>Atomizing</strong><br />

<strong>Air</strong><br />

<strong>Air</strong><br />

Capacity<br />

l/min<br />

Refer to page F3 for Siphon/Gravity-Fed Liquid Set-ups.<br />

Gravity Head (cm)<br />

Liquid Capacity<br />

(liters per minute)*<br />

*At the stated pressure in bar.<br />

Siphon Height (cm)<br />

45 30 15 10 20 30 60<br />

1.4 2971 – – 12.9 7.2 – – –<br />

1.75 3396 19.7 17.0 13.6 8.3 – – –<br />

2.1 3821 20.1 17.4 14.4 9.1 5.3 – –<br />

2.8 4670 20.4 17.8 14.8 9.8 6.8 4.2 –<br />

4.2 6368 20.8 18.5 15.9 11.0 8.3 5.7 1.5<br />

5.6 8066 21.2 18.9 16.6 11.4 8.7 6.1 1.9<br />

7.0 9764 21.6 19.3 17.0 11.7 9.1 6.4 2.3<br />

<strong>Spray</strong><br />

Dimensions<br />

Phone 1(630) 665-5000, FAX 1(630) 260-0842<br />

Visit Our Web Site: www.spray.com, Email: info@spray.com<br />

F53<br />

<strong>Air</strong>*<br />

2.1<br />

2.8<br />

3.5<br />

4.2<br />

4.9<br />

<strong>Air</strong>*<br />

2.1<br />

2.8<br />

4.2<br />

5.6<br />

7.0<br />

Liquid*<br />

.20<br />

.30<br />

.50<br />

.70<br />

1.0<br />

A<br />

(cm)<br />

51<br />

56<br />

58<br />

56<br />

56<br />

B<br />

(cm)<br />

91<br />

94<br />

99<br />

97<br />

99<br />

C<br />

(cm)<br />

119<br />

122<br />

130<br />

124<br />

127<br />

<strong>Spray</strong> Dimensions<br />

at 20 cm Siphon Height<br />

A<br />

(cm)<br />

13<br />

13<br />

13<br />

13<br />

13<br />

B<br />

(cm)<br />

26<br />

26<br />

26<br />

26<br />

26<br />

C<br />

(cm)<br />

38<br />

38<br />

38<br />

38<br />

38<br />

D<br />

(m)<br />

7.6<br />

8.5<br />

9.1<br />

9.8<br />

10.7<br />

D<br />

(m)<br />

8.8<br />

10.5<br />

13.4<br />

16.5<br />

19.5