15.05.2015 Views

Section F – Air Atomizing Spray Nozzles - Spraying Systems Co.

Section F – Air Atomizing Spray Nozzles - Spraying Systems Co.

Section F – Air Atomizing Spray Nozzles - Spraying Systems Co.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Humidification System <strong>Co</strong>mponents<br />

<strong>Air</strong> <strong>Atomizing</strong> <strong>Nozzles</strong><br />

Features and Benefits<br />

• 2335-SE pipe assembly consists of straight and formed tubing<br />

with fittings, globe valve and split-eyelet connectors.<br />

– Not assembled.<br />

• 11438-85 humidistat will respond to humidity levels in the<br />

range of 20% to 95% RH.<br />

– Maximum operating temperature 125°F (52°C). 24V DC; 110V.<br />

Overall height 6" (15 cm).<br />

• 11438-95 switching relay has built-in transformer that supplies<br />

low-voltage current for humidistat circuit.<br />

– 2-wire 24V control, 115V AC. Maximum temperature 115°F<br />

(46°C).<br />

• 55089 electric humidistat quick relative humidity LCD readouts<br />

from 1% to 99% with repeatability of ±5%.<br />

– Operating temperature range 32°F to 160°F (0°C to 71°C).<br />

– 24V (DC or AC).<br />

• 45604 float valve used in 45600 float box to shut off inlet flow<br />

at a preset water level.<br />

– Made of ABS plastic, 304 Stainless Steel, polypropylene<br />

with fiber washers and a brass nut.<br />

Optimization Tips<br />

• See page F2 for optimization tips.<br />

• 55400 valve package is easy to install and use – simply connect<br />

to existing air and fluid lines.<br />

– The NEMA type 4 panel is completely sealed to eliminate moisture<br />

damage to components.<br />

– Safety feature ensures there is no product damage due to<br />

unintentional water release.<br />

– Stainless steel components available for use with deionized water.<br />

– Separate atomizing and cylinder air lines with adjustable delay<br />

time assures liquid atomization.<br />

• 2202 pipe hanger for proper spacing between air and liquid lines.<br />

Sizes fit 1/2" piping.<br />

– Hanger is held by threaded rod and nuts (not included) for<br />

vertical adjustment.<br />

– Made of cast aluminum. 4" (10 cm) spacing.<br />

– Use with 2335-SE spray pipe assembly.<br />

See Also<br />

• Accessories<br />

– <strong>Air</strong> line filters<br />

– <strong>Air</strong> pressure regulators<br />

– Liquid pressure regulators<br />

• <strong>Section</strong> L, Accessories<br />

– Pressure gauges<br />

– Solenoid valves<br />

– Strainers<br />

• For 2335-SE pipe assembly, request Data Sheet 2335-SE<br />

• For 55089 electrical humidistat, request Data Sheet 55089<br />

http://<br />

2335-SE<br />

11438-85 11438-95<br />

55089<br />

<strong>Spray</strong> pipe assembly<br />

Humidistat<br />

Switching relay<br />

Electric humidistat<br />

45604 45600<br />

55400<br />

2202<br />

Float valve<br />

Float box<br />

Valve package<br />

Pipe hanger<br />

Phone 1(630) 665-5000, FAX 1(630) 260-0842<br />

Visit Our Web Site: www.spray.com, Email: info@spray.com<br />

F60