16.06.2015 Views

OLSG Report_Final_06_05_12 - Interagency Operations Advisory ...

OLSG Report_Final_06_05_12 - Interagency Operations Advisory ...

OLSG Report_Final_06_05_12 - Interagency Operations Advisory ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Optical Link Study Group (<strong>OLSG</strong>) <strong>Final</strong> <strong>Report</strong><br />

IOAG.T.<strong>OLSG</strong>.20<strong>12</strong>.V1<br />

RELAY FEEDER LINK DOW NLINK BUDGET<br />

INPUT PARAM ETERS<br />

LINK BUDGET<br />

Range 39.77E+03 km Tx Ave Power 26.99 dBm<br />

Elevation 20 deg Tx Photons / Pulse 3.90E+08<br />

TRANSMITTER<br />

Tx Antenna Gain<br />

1<strong>06</strong>.27 dBi<br />

Modulation Type DPSK Tx Transmission Loss -4.81 dB<br />

Tx Pointing Loss<br />

-0.27 dB<br />

Tx Wavelength 1.55 µm<br />

Tx Ave Power 0.5 W Isotropic Space Loss -290.17 dB<br />

Tx Data Rate 10.0E+09 Hz Atmospheric Loss -1.65 dB<br />

Tx Aperture Diam 0.1016 m Rx Antenna Gain <strong>12</strong>6.14 dBi<br />

Tx Angular Diam 4.01 arcsec Array Gain 0.00 dB<br />

Tx Footprint Diam 7.73E+02 m Rx Transmission Loss -5.80 dB<br />

Tx Optical Transmission 33.0 % Rx Pointing Loss 0.00 dB<br />

Tx Depointing 0.50 arcsec Rx Fiber Coupling Loss -4.00 dB<br />

Total Optical Path Loss<br />

-74.29 dB<br />

Uncoded Slot Rate 20.0E+09 s -1<br />

Uncoded Bits Per Word 0.50 Ave Power at Rx Detector -47.31 dBm<br />

Photons / Pulse at Rx Detector 14.51<br />

ATMOSPHERIC LOSSES<br />

Atm Zenith Transmittance 95.0 % Required Photons / Pulse 7.00<br />

Relative Airmass 2.90 Link M argin 3.17 dB<br />

Atm Transmission Along LOS 86.2 %<br />

Scintillation Loss -1.0 dB<br />

RECEIVER<br />

Rx Aperture Diam 1.00 m<br />

Rx FOV 5.00 arcsec<br />

Rx Depointing 0.00 arcsec<br />

Rx Optical Transmission 26.3 %<br />

Rx Array Size 1 apertures<br />

Fiber Coupling Loss -4.00 dB<br />

Required Photons / Pulse 7.00<br />

Code Rate 0.50<br />

Figure 80: Example downlink budget for an optical feeder link in an Earth<br />

relay scenario<br />

4.1.5.2.2.2 Uplink<br />

A sample uplink beacon budget for the GEO relay scenario is shown in Figure 81. The<br />

transmitter, with the configuration of Ground Station 2, consists of four 15 cm apertures.<br />

The average power per aperture is 2.5 W, for a total transmitted power of 10 W. The<br />

irradiance required at the receiver aperture is based on the acquisition procedure of LLCD.<br />

The link closes with a good margin of more than 21 dB; therefore, an average power of<br />

about 40 mW per aperture could be sufficient on the ground.<br />

Page | <strong>12</strong>9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!