(v)<br />
Indoor temperature sensor temperature, indoor heat exchanger sensor temperature, outdoor air<br />
temperature sensor temperature, outdoor heat exchanger sensor temperature table<br />
Units: ¡C<br />
TIMER light<br />
(1’s digit)<br />
Buzzer sound<br />
(minus)<br />
RUN light<br />
(10’s digit)<br />
0 1 2 3 4 5 6 7 8 9<br />
6<br />
-60<br />
-61<br />
-62<br />
-63<br />
-64<br />
5<br />
-50<br />
-51<br />
-52<br />
-53<br />
-54<br />
-55<br />
-56<br />
-57<br />
-58<br />
-59<br />
Yes<br />
(sounds for 0.1 second)<br />
4<br />
3<br />
2<br />
-40<br />
-30<br />
-20<br />
-41<br />
-31<br />
-21<br />
-42<br />
-32<br />
-22<br />
-43<br />
-33<br />
-23<br />
-44<br />
-34<br />
-24<br />
-45<br />
-35<br />
-25<br />
-46<br />
-36<br />
-26<br />
-47<br />
-37<br />
-27<br />
-48<br />
-38<br />
-28<br />
-49<br />
-39<br />
-29<br />
1<br />
-10<br />
-11<br />
-12<br />
-13<br />
-14<br />
-15<br />
-16<br />
-17<br />
-18<br />
-19<br />
0<br />
-1<br />
-2<br />
-3<br />
-4<br />
-5<br />
-6<br />
-7<br />
-8<br />
-9<br />
0<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
1<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
2<br />
20<br />
21<br />
22<br />
23<br />
24<br />
25<br />
26<br />
27<br />
28<br />
29<br />
3<br />
30<br />
31<br />
32<br />
33<br />
34<br />
35<br />
36<br />
37<br />
38<br />
39<br />
No<br />
(does not sound)<br />
4<br />
5<br />
40<br />
50<br />
41<br />
51<br />
42<br />
52<br />
43<br />
53<br />
44<br />
54<br />
45<br />
55<br />
46<br />
56<br />
47<br />
57<br />
48<br />
58<br />
49<br />
59<br />
6<br />
60<br />
61<br />
62<br />
63<br />
64<br />
65<br />
66<br />
67<br />
68<br />
69<br />
7<br />
70<br />
71<br />
72<br />
73<br />
74<br />
75<br />
76<br />
77<br />
78<br />
79<br />
8<br />
80<br />
81<br />
82<br />
83<br />
84<br />
85<br />
86<br />
87<br />
88<br />
89<br />
9<br />
90<br />
91<br />
92<br />
93<br />
94<br />
95<br />
96<br />
97<br />
98<br />
99<br />
* If no data are recorded (error code is normal), the display for each sensor becomes as shown below.<br />
Sensor name<br />
Room temperature sensor temperature<br />
Indoor heat exchanger sensor temperature<br />
Outdoor air temperature sensor temperature<br />
Outdoor heat exchanger temperature<br />
Sensor value displayed when the error code is normal<br />
-19¡C<br />
-64¡C<br />
-64¡C<br />
-64¡C<br />
(Example) Room temperature, indoor heat exchanger, outdoor air temperature, outdoor heat exchanger: “-9ºC”<br />
Buzzer sound<br />
(minus)<br />
ON<br />
0.1 sec.<br />
If the temperature is < 0, the buzzer sounds.<br />
If the temperature is > = 0, the buzzer does not sound.<br />
OFF<br />
RUN light<br />
(10Õs digit)<br />
ON<br />
OFF<br />
1.5 sec.<br />
0.5 sec.<br />
0.5 sec.<br />
TIMER light<br />
(1Õs digit)<br />
ON<br />
OFF<br />
11-second interval<br />
- 38 -