2.2 Range of usage & limitations<br />

Item<br />

Indoor return air temperature<br />

(Upper, lower limits)<br />

Outdoor air temperature<br />

(Upper, lower limits)<br />

Models<br />

<strong>SRK20ZGX</strong>-S, <strong>25ZGX</strong>-S, <strong>35ZGX</strong>-S<br />

SRK<strong>50ZGX</strong>-S<br />

Cooling operation: Approximately 21 to 32¡C<br />

Heating operation: Approximately 15 to 30¡C<br />

Cooling operation: Approximately -15 to 46¡C<br />

Heating operation: Approximately -15 to 21¡C<br />

Refrigerant line (one way) length<br />

Vertical height difference between<br />

outdoor unit and indoor unit<br />

Max. 15m<br />

Max. 10m (Outdoor unit is higher)<br />

Max. 10m (Outdoor unit is lower)<br />

Max. 25m<br />

Max. 15m (Outdoor unit is higher)<br />

Max. 15m (Outdoor unit is lower)<br />

Power source voltage Rating ± 10%<br />

Voltage at starting<br />

Min. 85% of rating<br />

Frequency of ON-OFF cycle<br />

Max. 4 times/h<br />

(Inching prevention: 10 min.)<br />

Max. 7 times/h<br />

(Inching prevention: 5 min.)<br />

ON and OFF interval<br />

Max. 3 minutes<br />

2.3 Exterior dimensions<br />

(1) Indoor unit<br />

Models All models<br />

A<br />

840<br />

259<br />

3<br />

Piping hole right<br />

298<br />

right: 67<br />

left : 60<br />

Indoor unit<br />

44<br />

9<br />

Installating board<br />

60<br />

73.5<br />

693<br />

73.5<br />

207.5<br />

450<br />

182.5<br />

47.5<br />

50<br />

50<br />

8.5<br />

813<br />

3<br />

60<br />

60 14.5<br />

220.5<br />

44.5<br />

53.5<br />

25<br />

63.5<br />

44.5<br />

5.3 284.2<br />

60<br />

44<br />

44<br />

60<br />

Drain hose 515 (¿16)<br />

20,25,35: ¿9.52<br />

Piping for gas 533.5 (<br />

50: ¿12.7)<br />

Piping for liquid 603.5 (¿6.35)<br />

VIEW A<br />

Piping hole (¿65) Piping hole (¿65)<br />

- 6 -