It is common practice in thermal NR to place behind the film/converter<br />

arrangement a cadmium screen to trap the back-scattered neutrons. In fast<br />

NR the following mountings are in use:<br />

1) For the nitrocellulose film only (Kodak CN 85): same mountings as<br />

mentioned above for the combined film.<br />

2) For the nitrocellulose film with polyethylene foil or for a nitrocellulose film<br />

stack (multifoil technique): vacuum or pressure cassette to ensure proper<br />

contact between all layers.<br />

Charlie Chong/ Fion Zhang<br />

Practical.NR Chapter 7